T1–T2 molecular magnetic resonance imaging of renal carcinoma cells based on nano-contrast agents

Jingjing Li,1,2,* Jia You,2,3,* Chen Wu,2 Yue Dai,1 Meilin Shi,2 Lina Dong,2 Kai Xu1,2 1Department of Radiology, Affiliated Hospital of Xuzhou Medical University, Xuzhou 221006, People’s Republic of China; 2School of Medical Imaging, Xuzhou Medical University, Xuzhou 221004, People&rs...

Full description

Bibliographic Details
Main Authors: Li J, You J, Wu C, Dai Y, Shi M, Dong L, Xu K
Format: Article
Language:English
Published: Dove Medical Press 2018-08-01
Series:International Journal of Nanomedicine
Subjects:
Online Access:https://www.dovepress.com/t1ndasht2-molecular-magnetic-resonance-imaging-of-renal-carcinoma-cell-peer-reviewed-article-IJN
id doaj-6977c9addc124e4f9d9cee82854edf90
record_format Article
spelling doaj-6977c9addc124e4f9d9cee82854edf902020-11-25T01:23:23ZengDove Medical PressInternational Journal of Nanomedicine1178-20132018-08-01Volume 134607462539770T1–T2 molecular magnetic resonance imaging of renal carcinoma cells based on nano-contrast agentsLi JYou JWu CDai YShi MDong LXu KJingjing Li,1,2,* Jia You,2,3,* Chen Wu,2 Yue Dai,1 Meilin Shi,2 Lina Dong,2 Kai Xu1,2 1Department of Radiology, Affiliated Hospital of Xuzhou Medical University, Xuzhou 221006, People’s Republic of China; 2School of Medical Imaging, Xuzhou Medical University, Xuzhou 221004, People’s Republic of China; 3Department of Radiology, Nanjing First Hospital, Nanjing Medical University, Nanjing 210006, People’s Republic of China *These authors contributed equally to this work Background: The development of T1–T2 dual contrast agent (CA) favors the visualization of the lesion in a more accurate and reliable manner by magnetic resonance imaging (MRI). The relaxivity and the interference between T1 and T2 CA are the main concerns for their design. Methods: In this work, we constructed an Fe3O4@mSiO2/PDDA/BSA-Gd2O3 nanocomplex where BSA-Gd2O3 NPs and Fe3O4 NPs were chosen as T1 and T2 MRI CAs and a 20 nm mesoporous silica (mSiO2) nanoshell was introduced to reduce the interference between them. We performed transmis­sion electron microscopy, X-ray powder diffraction, UV-vis absorption spectra, and Fourier transform infrared absorption (FTIR) spectra to characterize the prepared nanocomplex and MRI scanning to evaluate their MRI behaviors. Furthermore, 3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay and hematologic and biochemical analyses were introduced to evaluate their in vitro and in vivo toxicity. Finally, the specific MRI of 786-0 cells with Fe3O4@mSiO2/PDDA/BSA-Gd2O3-AS1411 nanoprobe in vitro was realized. In vivo biodistribution of Fe3O4@mSiO2/PDDA/BSA-Gd2O3 nanocomplex in the mouse was determined by the quantification of the Gd element by inductively coupled plasma-mass spectrometry. Results: The prepared Fe3O4@mSiO2/PDDA/BSA-Gd2O3 nanocomplex possessed high longitudinal (r1=11.47 mM s-1 Gd) and transverse (r2=195.1 mM s-1 Fe) relaxivities, enabling its use as a T1–T2 dual contrast agent for MRI. MTT testing and hematologic and biochemical analysis indicated the good biocompatibility of Fe3O4@mSiO2/PDDA/BSA-Gd2O3 nanocomplex in vitro and in vivo. After further conjugation with AS1411 aptamer, they could target tumor cells successfully by T1 and T2 MRI in vitro. The possible metabolic pathway of the tail vein-injected Fe3O4@mSiO2/PDDA/BSA-Gd2O3 nanocomplex in mouse was mainly via kidney. Conclusion: A T1–T2 dual-mode contrast agent, Fe3O4@mSiO2/PDDA/BSA-Gd2O3 nanocomplex, was developed and its good performance for tumor cell targeting in vitro and kidney contrast-enhanced MRI in mice indicated its promising potential as an effective T1–T2 dual-mode contrast agent for in vivo MRI with self-confirmation. Keywords: molecular magnetic resonance imaging, nano-contrast agent, aptamer, T1–T2, MRIhttps://www.dovepress.com/t1ndasht2-molecular-magnetic-resonance-imaging-of-renal-carcinoma-cell-peer-reviewed-article-IJNmolecular magnetic resonance imagingnano-contrast agentaptamerT1-T2
collection DOAJ
language English
format Article
sources DOAJ
author Li J
You J
Wu C
Dai Y
Shi M
Dong L
Xu K
spellingShingle Li J
You J
Wu C
Dai Y
Shi M
Dong L
Xu K
T1–T2 molecular magnetic resonance imaging of renal carcinoma cells based on nano-contrast agents
International Journal of Nanomedicine
molecular magnetic resonance imaging
nano-contrast agent
aptamer
T1-T2
author_facet Li J
You J
Wu C
Dai Y
Shi M
Dong L
Xu K
author_sort Li J
title T1–T2 molecular magnetic resonance imaging of renal carcinoma cells based on nano-contrast agents
title_short T1–T2 molecular magnetic resonance imaging of renal carcinoma cells based on nano-contrast agents
title_full T1–T2 molecular magnetic resonance imaging of renal carcinoma cells based on nano-contrast agents
title_fullStr T1–T2 molecular magnetic resonance imaging of renal carcinoma cells based on nano-contrast agents
title_full_unstemmed T1–T2 molecular magnetic resonance imaging of renal carcinoma cells based on nano-contrast agents
title_sort t1–t2 molecular magnetic resonance imaging of renal carcinoma cells based on nano-contrast agents
publisher Dove Medical Press
series International Journal of Nanomedicine
issn 1178-2013
publishDate 2018-08-01
description Jingjing Li,1,2,* Jia You,2,3,* Chen Wu,2 Yue Dai,1 Meilin Shi,2 Lina Dong,2 Kai Xu1,2 1Department of Radiology, Affiliated Hospital of Xuzhou Medical University, Xuzhou 221006, People’s Republic of China; 2School of Medical Imaging, Xuzhou Medical University, Xuzhou 221004, People’s Republic of China; 3Department of Radiology, Nanjing First Hospital, Nanjing Medical University, Nanjing 210006, People’s Republic of China *These authors contributed equally to this work Background: The development of T1–T2 dual contrast agent (CA) favors the visualization of the lesion in a more accurate and reliable manner by magnetic resonance imaging (MRI). The relaxivity and the interference between T1 and T2 CA are the main concerns for their design. Methods: In this work, we constructed an Fe3O4@mSiO2/PDDA/BSA-Gd2O3 nanocomplex where BSA-Gd2O3 NPs and Fe3O4 NPs were chosen as T1 and T2 MRI CAs and a 20 nm mesoporous silica (mSiO2) nanoshell was introduced to reduce the interference between them. We performed transmis­sion electron microscopy, X-ray powder diffraction, UV-vis absorption spectra, and Fourier transform infrared absorption (FTIR) spectra to characterize the prepared nanocomplex and MRI scanning to evaluate their MRI behaviors. Furthermore, 3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay and hematologic and biochemical analyses were introduced to evaluate their in vitro and in vivo toxicity. Finally, the specific MRI of 786-0 cells with Fe3O4@mSiO2/PDDA/BSA-Gd2O3-AS1411 nanoprobe in vitro was realized. In vivo biodistribution of Fe3O4@mSiO2/PDDA/BSA-Gd2O3 nanocomplex in the mouse was determined by the quantification of the Gd element by inductively coupled plasma-mass spectrometry. Results: The prepared Fe3O4@mSiO2/PDDA/BSA-Gd2O3 nanocomplex possessed high longitudinal (r1=11.47 mM s-1 Gd) and transverse (r2=195.1 mM s-1 Fe) relaxivities, enabling its use as a T1–T2 dual contrast agent for MRI. MTT testing and hematologic and biochemical analysis indicated the good biocompatibility of Fe3O4@mSiO2/PDDA/BSA-Gd2O3 nanocomplex in vitro and in vivo. After further conjugation with AS1411 aptamer, they could target tumor cells successfully by T1 and T2 MRI in vitro. The possible metabolic pathway of the tail vein-injected Fe3O4@mSiO2/PDDA/BSA-Gd2O3 nanocomplex in mouse was mainly via kidney. Conclusion: A T1–T2 dual-mode contrast agent, Fe3O4@mSiO2/PDDA/BSA-Gd2O3 nanocomplex, was developed and its good performance for tumor cell targeting in vitro and kidney contrast-enhanced MRI in mice indicated its promising potential as an effective T1–T2 dual-mode contrast agent for in vivo MRI with self-confirmation. Keywords: molecular magnetic resonance imaging, nano-contrast agent, aptamer, T1–T2, MRI
topic molecular magnetic resonance imaging
nano-contrast agent
aptamer
T1-T2
url https://www.dovepress.com/t1ndasht2-molecular-magnetic-resonance-imaging-of-renal-carcinoma-cell-peer-reviewed-article-IJN
work_keys_str_mv AT lij t1ndasht2molecularmagneticresonanceimagingofrenalcarcinomacellsbasedonnanocontrastagents
AT youj t1ndasht2molecularmagneticresonanceimagingofrenalcarcinomacellsbasedonnanocontrastagents
AT wuc t1ndasht2molecularmagneticresonanceimagingofrenalcarcinomacellsbasedonnanocontrastagents
AT daiy t1ndasht2molecularmagneticresonanceimagingofrenalcarcinomacellsbasedonnanocontrastagents
AT shim t1ndasht2molecularmagneticresonanceimagingofrenalcarcinomacellsbasedonnanocontrastagents
AT dongl t1ndasht2molecularmagneticresonanceimagingofrenalcarcinomacellsbasedonnanocontrastagents
AT xuk t1ndasht2molecularmagneticresonanceimagingofrenalcarcinomacellsbasedonnanocontrastagents
_version_ 1725122498594340864