VALIDATION OF CYCLAMATE ANALYSIS METHOD WITH SPECTROPHOTOMETRY AND TURBIDIMETRY

This research aims to validate methods of analysis by spectrophotometry and turbidimetry cyclamate in the sample drink mango-flavored jelly drink  by spectrophotometry with hypochlorite reagent, ultraviolet spectrophotometry (without reagent) and turbidimetry. The object of research was the validity...

Full description

Bibliographic Details
Main Authors: Regina Tutik Padmaningrum, Siti Marwati
Format: Article
Language:Indonesian
Published: Universitas Negeri Yogyakarta 2016-04-01
Series:Jurnal Sains Dasar
Online Access:http://journal.uny.ac.id/index.php/jsd/article/view/8435
id doaj-6940d98aec324dc2a001061290942a7b
record_format Article
spelling doaj-6940d98aec324dc2a001061290942a7b2020-11-25T00:36:22ZindUniversitas Negeri YogyakartaJurnal Sains Dasar2085-98722443-12732016-04-01416788VALIDATION OF CYCLAMATE ANALYSIS METHOD WITH SPECTROPHOTOMETRY AND TURBIDIMETRYRegina Tutik PadmaningrumSiti MarwatiThis research aims to validate methods of analysis by spectrophotometry and turbidimetry cyclamate in the sample drink mango-flavored jelly drink  by spectrophotometry with hypochlorite reagent, ultraviolet spectrophotometry (without reagent) and turbidimetry. The object of research was the validity parameters spectrophotometric method were linearity, linear range, the limit of detection, limit of quantitation, precision, and accuracy. The calibration curve of standard solution of sodium cyclamate in the spectrophotometric method with hypochlorite reagent, UV spectrophotometry (without reagent), and turbidimetry are linear. Linear range each method respectively at a concentration were (211.36-747.08); (16.000-146.434); and (1.8521-6.1717) ppm. The detection limit of each method successively were 53.6028; 0.5833; and 0.2723 ppm. Limit of quantitation each method successively were 66.9948; 1.9443; and 0.8068 ppm. Spectrophotometric analysis method cyclamate with hypochlorite reagent had good precision and accuracy. Ultra violet  spectrophotometric analysis method of cyclamate have a good precision but the accuracy was not good. Turbidimetric methods  analysis of cyclamate had  precision and accuracy were not good. Keywords:   method validation, spectrophotometry, turbidimetry, cyclamatehttp://journal.uny.ac.id/index.php/jsd/article/view/8435
collection DOAJ
language Indonesian
format Article
sources DOAJ
author Regina Tutik Padmaningrum
Siti Marwati
spellingShingle Regina Tutik Padmaningrum
Siti Marwati
VALIDATION OF CYCLAMATE ANALYSIS METHOD WITH SPECTROPHOTOMETRY AND TURBIDIMETRY
Jurnal Sains Dasar
author_facet Regina Tutik Padmaningrum
Siti Marwati
author_sort Regina Tutik Padmaningrum
title VALIDATION OF CYCLAMATE ANALYSIS METHOD WITH SPECTROPHOTOMETRY AND TURBIDIMETRY
title_short VALIDATION OF CYCLAMATE ANALYSIS METHOD WITH SPECTROPHOTOMETRY AND TURBIDIMETRY
title_full VALIDATION OF CYCLAMATE ANALYSIS METHOD WITH SPECTROPHOTOMETRY AND TURBIDIMETRY
title_fullStr VALIDATION OF CYCLAMATE ANALYSIS METHOD WITH SPECTROPHOTOMETRY AND TURBIDIMETRY
title_full_unstemmed VALIDATION OF CYCLAMATE ANALYSIS METHOD WITH SPECTROPHOTOMETRY AND TURBIDIMETRY
title_sort validation of cyclamate analysis method with spectrophotometry and turbidimetry
publisher Universitas Negeri Yogyakarta
series Jurnal Sains Dasar
issn 2085-9872
2443-1273
publishDate 2016-04-01
description This research aims to validate methods of analysis by spectrophotometry and turbidimetry cyclamate in the sample drink mango-flavored jelly drink  by spectrophotometry with hypochlorite reagent, ultraviolet spectrophotometry (without reagent) and turbidimetry. The object of research was the validity parameters spectrophotometric method were linearity, linear range, the limit of detection, limit of quantitation, precision, and accuracy. The calibration curve of standard solution of sodium cyclamate in the spectrophotometric method with hypochlorite reagent, UV spectrophotometry (without reagent), and turbidimetry are linear. Linear range each method respectively at a concentration were (211.36-747.08); (16.000-146.434); and (1.8521-6.1717) ppm. The detection limit of each method successively were 53.6028; 0.5833; and 0.2723 ppm. Limit of quantitation each method successively were 66.9948; 1.9443; and 0.8068 ppm. Spectrophotometric analysis method cyclamate with hypochlorite reagent had good precision and accuracy. Ultra violet  spectrophotometric analysis method of cyclamate have a good precision but the accuracy was not good. Turbidimetric methods  analysis of cyclamate had  precision and accuracy were not good. Keywords:   method validation, spectrophotometry, turbidimetry, cyclamate
url http://journal.uny.ac.id/index.php/jsd/article/view/8435
work_keys_str_mv AT reginatutikpadmaningrum validationofcyclamateanalysismethodwithspectrophotometryandturbidimetry
AT sitimarwati validationofcyclamateanalysismethodwithspectrophotometryandturbidimetry
_version_ 1725305715379142656