Doppler ultrasound and contrast-enhanced ultrasound in detection of stent stenosis after iliac vein stenting
Abstract Background To compare the diagnostic accuracy of Doppler ultrasound (DUS) with contrast-enhanced ultrasound (CEUS) for detection of iliac vein stent stenosis using multidetector computed tomography venography (MDCTV) as the reference method. Methods Patients with iliac vein obstructive dise...
Main Authors: | , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
BMC
2021-01-01
|
Series: | BMC Cardiovascular Disorders |
Subjects: | |
Online Access: | https://doi.org/10.1186/s12872-020-01840-3 |
id |
doaj-692942dcf8634054bce46d00f4974c4a |
---|---|
record_format |
Article |
spelling |
doaj-692942dcf8634054bce46d00f4974c4a2021-01-24T12:22:40ZengBMCBMC Cardiovascular Disorders1471-22612021-01-012111710.1186/s12872-020-01840-3Doppler ultrasound and contrast-enhanced ultrasound in detection of stent stenosis after iliac vein stentingHong Liu0Jing Wang1Yu Zhao2Zheng Chen3Dong Wang4Miao Wei5Fajin Lv6Xiaoping Ye7Department of Vascular Surgery, the First Affiliated Hospital of Chongqing Medical UniversityDepartment of Ultrasound, the First Affiliated Hospital of Chongqing Medical UniversityDepartment of Vascular Surgery, the First Affiliated Hospital of Chongqing Medical UniversityDepartment of Vascular Surgery, the First Affiliated Hospital of Chongqing Medical UniversityDepartment of Ultrasound, the First Affiliated Hospital of Chongqing Medical UniversityDepartment of Radiology, the First Affiliated Hospital of Chongqing Medical UniversityDepartment of Radiology, the First Affiliated Hospital of Chongqing Medical UniversityDepartment of Ultrasound, the First Affiliated Hospital of Chongqing Medical UniversityAbstract Background To compare the diagnostic accuracy of Doppler ultrasound (DUS) with contrast-enhanced ultrasound (CEUS) for detection of iliac vein stent stenosis using multidetector computed tomography venography (MDCTV) as the reference method. Methods Patients with iliac vein obstructive disease treated with nitinol stents (Smart Control, Cordis, USA) between January 2016 and December 2017 were consecutively included in this study. DUS, CEUS, and MDCTV were carried out in all patients within one week of each other at 1 year post stenting to investigate the presence of stent compression and in-stent restenosis (ISR). Results The study included 139 patients (87 females; mean age 58 ± 15 years). For detecting stent compression, the kappa coefficient between the ultrasound modality of gray-scale imaging and MDCTV was 0.901, indicating very good agreement between these two modalities. ISR was detected in 50, 61, and 65 patients by DUS, CEUS, and MDCTV, respectively. DUS and CEUS (kappa = 0.449) and DUS and MDCTV (kappa = 0.516) had moderate agreement for ISR diagnosis, while for which CEUS and MDCTV (kappa 0.884) had very good agreement. The sensitivity and specificity of DUS and CEUS for diagnosing ISR were 63.1% and 90.8%, 87.8% and 97.3%, respectively. Conclusions CEUS is probably superior to DUS in terms of diagnostic accuracy for the follow-up of patients with iliac vein stent stenosis.https://doi.org/10.1186/s12872-020-01840-3Contrast-enhanced ultrasoundMultidetector computed tomography venographyIliac vein obstructive diseaseStentFollow-up |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Hong Liu Jing Wang Yu Zhao Zheng Chen Dong Wang Miao Wei Fajin Lv Xiaoping Ye |
spellingShingle |
Hong Liu Jing Wang Yu Zhao Zheng Chen Dong Wang Miao Wei Fajin Lv Xiaoping Ye Doppler ultrasound and contrast-enhanced ultrasound in detection of stent stenosis after iliac vein stenting BMC Cardiovascular Disorders Contrast-enhanced ultrasound Multidetector computed tomography venography Iliac vein obstructive disease Stent Follow-up |
author_facet |
Hong Liu Jing Wang Yu Zhao Zheng Chen Dong Wang Miao Wei Fajin Lv Xiaoping Ye |
author_sort |
Hong Liu |
title |
Doppler ultrasound and contrast-enhanced ultrasound in detection of stent stenosis after iliac vein stenting |
title_short |
Doppler ultrasound and contrast-enhanced ultrasound in detection of stent stenosis after iliac vein stenting |
title_full |
Doppler ultrasound and contrast-enhanced ultrasound in detection of stent stenosis after iliac vein stenting |
title_fullStr |
Doppler ultrasound and contrast-enhanced ultrasound in detection of stent stenosis after iliac vein stenting |
title_full_unstemmed |
Doppler ultrasound and contrast-enhanced ultrasound in detection of stent stenosis after iliac vein stenting |
title_sort |
doppler ultrasound and contrast-enhanced ultrasound in detection of stent stenosis after iliac vein stenting |
publisher |
BMC |
series |
BMC Cardiovascular Disorders |
issn |
1471-2261 |
publishDate |
2021-01-01 |
description |
Abstract Background To compare the diagnostic accuracy of Doppler ultrasound (DUS) with contrast-enhanced ultrasound (CEUS) for detection of iliac vein stent stenosis using multidetector computed tomography venography (MDCTV) as the reference method. Methods Patients with iliac vein obstructive disease treated with nitinol stents (Smart Control, Cordis, USA) between January 2016 and December 2017 were consecutively included in this study. DUS, CEUS, and MDCTV were carried out in all patients within one week of each other at 1 year post stenting to investigate the presence of stent compression and in-stent restenosis (ISR). Results The study included 139 patients (87 females; mean age 58 ± 15 years). For detecting stent compression, the kappa coefficient between the ultrasound modality of gray-scale imaging and MDCTV was 0.901, indicating very good agreement between these two modalities. ISR was detected in 50, 61, and 65 patients by DUS, CEUS, and MDCTV, respectively. DUS and CEUS (kappa = 0.449) and DUS and MDCTV (kappa = 0.516) had moderate agreement for ISR diagnosis, while for which CEUS and MDCTV (kappa 0.884) had very good agreement. The sensitivity and specificity of DUS and CEUS for diagnosing ISR were 63.1% and 90.8%, 87.8% and 97.3%, respectively. Conclusions CEUS is probably superior to DUS in terms of diagnostic accuracy for the follow-up of patients with iliac vein stent stenosis. |
topic |
Contrast-enhanced ultrasound Multidetector computed tomography venography Iliac vein obstructive disease Stent Follow-up |
url |
https://doi.org/10.1186/s12872-020-01840-3 |
work_keys_str_mv |
AT hongliu dopplerultrasoundandcontrastenhancedultrasoundindetectionofstentstenosisafteriliacveinstenting AT jingwang dopplerultrasoundandcontrastenhancedultrasoundindetectionofstentstenosisafteriliacveinstenting AT yuzhao dopplerultrasoundandcontrastenhancedultrasoundindetectionofstentstenosisafteriliacveinstenting AT zhengchen dopplerultrasoundandcontrastenhancedultrasoundindetectionofstentstenosisafteriliacveinstenting AT dongwang dopplerultrasoundandcontrastenhancedultrasoundindetectionofstentstenosisafteriliacveinstenting AT miaowei dopplerultrasoundandcontrastenhancedultrasoundindetectionofstentstenosisafteriliacveinstenting AT fajinlv dopplerultrasoundandcontrastenhancedultrasoundindetectionofstentstenosisafteriliacveinstenting AT xiaopingye dopplerultrasoundandcontrastenhancedultrasoundindetectionofstentstenosisafteriliacveinstenting |
_version_ |
1724325897870245888 |