Shear wave elastography using ultrasound: effects of anisotropy and stretch stress on a tissue phantom and reactive lymph nodes in the neck
Purpose The purpose of this study was to evaluate how the anisotropy and the static stretch stress of the cervical musculature influence the measured shear modulus in a tissue-mimicking phantom and in cervical lymph nodes in vivo by using shear wave elastography (SWE). Methods SWE was performed on a...
Main Authors: | , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Korean Society of Ultrasound in Medicine
2017-01-01
|
Series: | Ultrasonography |
Subjects: | |
Online Access: | http://e-ultrasonography.org/upload/usg-16003.pdf |
id |
doaj-68cda96199974472a5c01716a7ea27fc |
---|---|
record_format |
Article |
spelling |
doaj-68cda96199974472a5c01716a7ea27fc2020-11-24T21:27:53ZengKorean Society of Ultrasound in MedicineUltrasonography2288-59192288-59432017-01-01361253210.14366/usg.16003139Shear wave elastography using ultrasound: effects of anisotropy and stretch stress on a tissue phantom and reactive lymph nodes in the neckHa Young Lee0Jeong Hyun Lee1Ji Hoon Shin2So Yeon Kim3Hee Jung Shin4Jeong Seon Park5Young Jun Choi6Jung Hwan Baek7 Department of Radiology, University of Inha College of Medicine, Incheon, Korea Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea Department of Radiology, Hanyang University College of Medicine, Seoul, Korea Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, KoreaPurpose The purpose of this study was to evaluate how the anisotropy and the static stretch stress of the cervical musculature influence the measured shear modulus in a tissue-mimicking phantom and in cervical lymph nodes in vivo by using shear wave elastography (SWE). Methods SWE was performed on a phantom using a pig muscle and on the middle jugular cervical lymph nodes in six volunteers. Tissue elasticity was quantified using the shear modulus and a supersonic shear wave imaging technique. For the phantom study, first, the optimal depth for measurement was determined, and then, SWE was performed in parallel and perpendicular to the muscle fiber orientation with and without strain stress. For the in vivo study, SWE was performed on the cervical lymph nodes in parallel and perpendicular to the sternocleidomastoid muscle fiber direction with and without neck stretching. The mean values of the shear modulus (meanSM) were then analyzed. Results In the phantom study, the measured depth significantly influenced the meanSM with a sharp decrease at the depth of 1.5 cm (P<0.001). Strain stress increased the meanSM, irrespective of the muscle fiber orientation (P<0.001). In the in vivo study, the meanSM values obtained in parallel to the muscle fiber orientation were greater than those obtained perpendicular to the fiber orientation, irrespective of the stretch stress (P<0.001). However, meanSM was affected significantly by the stretch stress parallel to the muscle fiber orientation (P<0.001). Conclusion The anisotropic nature of the cervical musculature and the applied stretch stress explain the variability of the SWE measurements and should be identified before applying SWE for the interpretation of the measured shear modulus values.http://e-ultrasonography.org/upload/usg-16003.pdfNeckLymph nodesElasticity imaging techniquesShear wave imagingAnisotropyElasticity imaging techniques |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Ha Young Lee Jeong Hyun Lee Ji Hoon Shin So Yeon Kim Hee Jung Shin Jeong Seon Park Young Jun Choi Jung Hwan Baek |
spellingShingle |
Ha Young Lee Jeong Hyun Lee Ji Hoon Shin So Yeon Kim Hee Jung Shin Jeong Seon Park Young Jun Choi Jung Hwan Baek Shear wave elastography using ultrasound: effects of anisotropy and stretch stress on a tissue phantom and reactive lymph nodes in the neck Ultrasonography Neck Lymph nodes Elasticity imaging techniques Shear wave imaging Anisotropy Elasticity imaging techniques |
author_facet |
Ha Young Lee Jeong Hyun Lee Ji Hoon Shin So Yeon Kim Hee Jung Shin Jeong Seon Park Young Jun Choi Jung Hwan Baek |
author_sort |
Ha Young Lee |
title |
Shear wave elastography using ultrasound: effects of anisotropy and stretch stress on a tissue phantom and reactive lymph nodes in the neck |
title_short |
Shear wave elastography using ultrasound: effects of anisotropy and stretch stress on a tissue phantom and reactive lymph nodes in the neck |
title_full |
Shear wave elastography using ultrasound: effects of anisotropy and stretch stress on a tissue phantom and reactive lymph nodes in the neck |
title_fullStr |
Shear wave elastography using ultrasound: effects of anisotropy and stretch stress on a tissue phantom and reactive lymph nodes in the neck |
title_full_unstemmed |
Shear wave elastography using ultrasound: effects of anisotropy and stretch stress on a tissue phantom and reactive lymph nodes in the neck |
title_sort |
shear wave elastography using ultrasound: effects of anisotropy and stretch stress on a tissue phantom and reactive lymph nodes in the neck |
publisher |
Korean Society of Ultrasound in Medicine |
series |
Ultrasonography |
issn |
2288-5919 2288-5943 |
publishDate |
2017-01-01 |
description |
Purpose The purpose of this study was to evaluate how the anisotropy and the static stretch stress of the cervical musculature influence the measured shear modulus in a tissue-mimicking phantom and in cervical lymph nodes in vivo by using shear wave elastography (SWE). Methods SWE was performed on a phantom using a pig muscle and on the middle jugular cervical lymph nodes in six volunteers. Tissue elasticity was quantified using the shear modulus and a supersonic shear wave imaging technique. For the phantom study, first, the optimal depth for measurement was determined, and then, SWE was performed in parallel and perpendicular to the muscle fiber orientation with and without strain stress. For the in vivo study, SWE was performed on the cervical lymph nodes in parallel and perpendicular to the sternocleidomastoid muscle fiber direction with and without neck stretching. The mean values of the shear modulus (meanSM) were then analyzed. Results In the phantom study, the measured depth significantly influenced the meanSM with a sharp decrease at the depth of 1.5 cm (P<0.001). Strain stress increased the meanSM, irrespective of the muscle fiber orientation (P<0.001). In the in vivo study, the meanSM values obtained in parallel to the muscle fiber orientation were greater than those obtained perpendicular to the fiber orientation, irrespective of the stretch stress (P<0.001). However, meanSM was affected significantly by the stretch stress parallel to the muscle fiber orientation (P<0.001). Conclusion The anisotropic nature of the cervical musculature and the applied stretch stress explain the variability of the SWE measurements and should be identified before applying SWE for the interpretation of the measured shear modulus values. |
topic |
Neck Lymph nodes Elasticity imaging techniques Shear wave imaging Anisotropy Elasticity imaging techniques |
url |
http://e-ultrasonography.org/upload/usg-16003.pdf |
work_keys_str_mv |
AT hayounglee shearwaveelastographyusingultrasoundeffectsofanisotropyandstretchstressonatissuephantomandreactivelymphnodesintheneck AT jeonghyunlee shearwaveelastographyusingultrasoundeffectsofanisotropyandstretchstressonatissuephantomandreactivelymphnodesintheneck AT jihoonshin shearwaveelastographyusingultrasoundeffectsofanisotropyandstretchstressonatissuephantomandreactivelymphnodesintheneck AT soyeonkim shearwaveelastographyusingultrasoundeffectsofanisotropyandstretchstressonatissuephantomandreactivelymphnodesintheneck AT heejungshin shearwaveelastographyusingultrasoundeffectsofanisotropyandstretchstressonatissuephantomandreactivelymphnodesintheneck AT jeongseonpark shearwaveelastographyusingultrasoundeffectsofanisotropyandstretchstressonatissuephantomandreactivelymphnodesintheneck AT youngjunchoi shearwaveelastographyusingultrasoundeffectsofanisotropyandstretchstressonatissuephantomandreactivelymphnodesintheneck AT junghwanbaek shearwaveelastographyusingultrasoundeffectsofanisotropyandstretchstressonatissuephantomandreactivelymphnodesintheneck |
_version_ |
1725972707855564800 |