Development and Application of Live Replacement of Insulator Suspension Tool Components for Transmission Lines
Transmission line insulators will reduce the insulation level and become low-value insulators because of lightning flashover. Toughened glass insulators are used in 500kV Tongfeng 1 and 2 lines in Tonghua area. Most umbrella skirts will break and fall off after lightning flashover, which greatly red...
Main Authors: | , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
EDP Sciences
2019-01-01
|
Series: | E3S Web of Conferences |
Online Access: | https://www.e3s-conferences.org/articles/e3sconf/pdf/2019/62/e3sconf_icbte2019_04010.pdf |
id |
doaj-68a3d8f826a14e5fad7cef0054e95ab2 |
---|---|
record_format |
Article |
spelling |
doaj-68a3d8f826a14e5fad7cef0054e95ab22021-04-02T14:47:42ZengEDP SciencesE3S Web of Conferences2267-12422019-01-011360401010.1051/e3sconf/201913604010e3sconf_icbte2019_04010Development and Application of Live Replacement of Insulator Suspension Tool Components for Transmission LinesJun Ma0Liang Yu1Yonggang Shi2Gang Dong3Fuxing Gong4Kegang Wei5Xin Su6Yushuai Ren7State Grid Tonghua Power Supply CompanUniversity of Edinburgh, Architecture, Minto HouseState Grid Tonghua Power Supply CompanState Grid Tonghua Power Supply CompanState Grid Tonghua Power Supply CompanState Grid Tonghua Power Supply CompanState Grid Tonghua Power Supply CompanState Grid Tonghua Power Supply CompanTransmission line insulators will reduce the insulation level and become low-value insulators because of lightning flashover. Toughened glass insulators are used in 500kV Tongfeng 1 and 2 lines in Tonghua area. Most umbrella skirts will break and fall off after lightning flashover, which greatly reduces the insulation performance. It needs to be replaced in time, but frequent blackouts will bring great losses and reduce the reliability of power supply. Aiming at the frequent lightning hazards and lightning strikes on transmission lines in Tonghua area, a tool assembly for live replacement of insulators for transmission lines is developed. Through the application of this tool, the live operation mode is adopted to eliminate such defects. The operation time can be arranged and implemented in a very timely manner, which avoids the threat of long-term defects, effectively reduces the outage time of equipment, enhances the stability of power grid, and greatly improves the reliability of power supply of lines. Finally, taking the live line insulator suspension tool as an example, the economic benefit analysis is given, and the feasibility and correctness of the tool are verified..https://www.e3s-conferences.org/articles/e3sconf/pdf/2019/62/e3sconf_icbte2019_04010.pdf |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Jun Ma Liang Yu Yonggang Shi Gang Dong Fuxing Gong Kegang Wei Xin Su Yushuai Ren |
spellingShingle |
Jun Ma Liang Yu Yonggang Shi Gang Dong Fuxing Gong Kegang Wei Xin Su Yushuai Ren Development and Application of Live Replacement of Insulator Suspension Tool Components for Transmission Lines E3S Web of Conferences |
author_facet |
Jun Ma Liang Yu Yonggang Shi Gang Dong Fuxing Gong Kegang Wei Xin Su Yushuai Ren |
author_sort |
Jun Ma |
title |
Development and Application of Live Replacement of Insulator Suspension Tool Components for Transmission Lines |
title_short |
Development and Application of Live Replacement of Insulator Suspension Tool Components for Transmission Lines |
title_full |
Development and Application of Live Replacement of Insulator Suspension Tool Components for Transmission Lines |
title_fullStr |
Development and Application of Live Replacement of Insulator Suspension Tool Components for Transmission Lines |
title_full_unstemmed |
Development and Application of Live Replacement of Insulator Suspension Tool Components for Transmission Lines |
title_sort |
development and application of live replacement of insulator suspension tool components for transmission lines |
publisher |
EDP Sciences |
series |
E3S Web of Conferences |
issn |
2267-1242 |
publishDate |
2019-01-01 |
description |
Transmission line insulators will reduce the insulation level and become low-value insulators because of lightning flashover. Toughened glass insulators are used in 500kV Tongfeng 1 and 2 lines in Tonghua area. Most umbrella skirts will break and fall off after lightning flashover, which greatly reduces the insulation performance. It needs to be replaced in time, but frequent blackouts will bring great losses and reduce the reliability of power supply. Aiming at the frequent lightning hazards and lightning strikes on transmission lines in Tonghua area, a tool assembly for live replacement of insulators for transmission lines is developed. Through the application of this tool, the live operation mode is adopted to eliminate such defects. The operation time can be arranged and implemented in a very timely manner, which avoids the threat of long-term defects, effectively reduces the outage time of equipment, enhances the stability of power grid, and greatly improves the reliability of power supply of lines. Finally, taking the live line insulator suspension tool as an example, the economic benefit analysis is given, and the feasibility and correctness of the tool are verified.. |
url |
https://www.e3s-conferences.org/articles/e3sconf/pdf/2019/62/e3sconf_icbte2019_04010.pdf |
work_keys_str_mv |
AT junma developmentandapplicationoflivereplacementofinsulatorsuspensiontoolcomponentsfortransmissionlines AT liangyu developmentandapplicationoflivereplacementofinsulatorsuspensiontoolcomponentsfortransmissionlines AT yonggangshi developmentandapplicationoflivereplacementofinsulatorsuspensiontoolcomponentsfortransmissionlines AT gangdong developmentandapplicationoflivereplacementofinsulatorsuspensiontoolcomponentsfortransmissionlines AT fuxinggong developmentandapplicationoflivereplacementofinsulatorsuspensiontoolcomponentsfortransmissionlines AT kegangwei developmentandapplicationoflivereplacementofinsulatorsuspensiontoolcomponentsfortransmissionlines AT xinsu developmentandapplicationoflivereplacementofinsulatorsuspensiontoolcomponentsfortransmissionlines AT yushuairen developmentandapplicationoflivereplacementofinsulatorsuspensiontoolcomponentsfortransmissionlines |
_version_ |
1721561309506437120 |