The effect of off-center placement of twisted tape on flow and heat transfer characteristics in a circular tube

Abstract This study is conducted to investigate the effect of off-center placement of twisted tape on flow distribution and heat transfer in a circular tube. The effect of tape width of 20, 18, 16, 14 and 12 mm on the heat transfer performance is discussed under the same twist ratio of 2.0. The nume...

Full description

Bibliographic Details
Main Authors: Li Wang, Peiyong Ni, Guannan Xi
Format: Article
Language:English
Published: Nature Publishing Group 2021-03-01
Series:Scientific Reports
Online Access:https://doi.org/10.1038/s41598-021-86285-0
id doaj-6825a7a932644c778e218578ed6a4654
record_format Article
spelling doaj-6825a7a932644c778e218578ed6a46542021-03-28T11:30:35ZengNature Publishing GroupScientific Reports2045-23222021-03-0111111110.1038/s41598-021-86285-0The effect of off-center placement of twisted tape on flow and heat transfer characteristics in a circular tubeLi Wang0Peiyong Ni1Guannan Xi2School of Mechanical Engineering, Nantong UniversitySchool of Mechanical Engineering, Nantong UniversitySchool of Mechanical Engineering, Nantong UniversityAbstract This study is conducted to investigate the effect of off-center placement of twisted tape on flow distribution and heat transfer in a circular tube. The effect of tape width of 20, 18, 16, 14 and 12 mm on the heat transfer performance is discussed under the same twist ratio of 2.0. The numerical analysis of the flow field, average Nusselt number, friction factor and thermo-hydraulic performance parameter of the tube are discussed with Reynolds number ranged from 2600 to 8760. The results indicate that the Nusselt number of the tube fitted with center-placed twisted tapes at various width is 7–51% higher than the plain tube, and performance in low Reynolds region was found more effective than that in high Reynolds region. The heat transfer for circular tube with twisted tape attached to the wall shows better performance than that for the tube with center-placed twisted tape. With a smaller tape width, a higher increasing ratio of Nu-wall/Nu-center is obtained. The increasing ratio for Nusselt number ranged from 3 to 18%. However, the use of twisted tape inserts is not beneficial for energy saving. The thermo-hydraulic performance parameters for convective heat transfer of helium gas flowing in a circular tube are below unity for the calculated Reynolds region.https://doi.org/10.1038/s41598-021-86285-0
collection DOAJ
language English
format Article
sources DOAJ
author Li Wang
Peiyong Ni
Guannan Xi
spellingShingle Li Wang
Peiyong Ni
Guannan Xi
The effect of off-center placement of twisted tape on flow and heat transfer characteristics in a circular tube
Scientific Reports
author_facet Li Wang
Peiyong Ni
Guannan Xi
author_sort Li Wang
title The effect of off-center placement of twisted tape on flow and heat transfer characteristics in a circular tube
title_short The effect of off-center placement of twisted tape on flow and heat transfer characteristics in a circular tube
title_full The effect of off-center placement of twisted tape on flow and heat transfer characteristics in a circular tube
title_fullStr The effect of off-center placement of twisted tape on flow and heat transfer characteristics in a circular tube
title_full_unstemmed The effect of off-center placement of twisted tape on flow and heat transfer characteristics in a circular tube
title_sort effect of off-center placement of twisted tape on flow and heat transfer characteristics in a circular tube
publisher Nature Publishing Group
series Scientific Reports
issn 2045-2322
publishDate 2021-03-01
description Abstract This study is conducted to investigate the effect of off-center placement of twisted tape on flow distribution and heat transfer in a circular tube. The effect of tape width of 20, 18, 16, 14 and 12 mm on the heat transfer performance is discussed under the same twist ratio of 2.0. The numerical analysis of the flow field, average Nusselt number, friction factor and thermo-hydraulic performance parameter of the tube are discussed with Reynolds number ranged from 2600 to 8760. The results indicate that the Nusselt number of the tube fitted with center-placed twisted tapes at various width is 7–51% higher than the plain tube, and performance in low Reynolds region was found more effective than that in high Reynolds region. The heat transfer for circular tube with twisted tape attached to the wall shows better performance than that for the tube with center-placed twisted tape. With a smaller tape width, a higher increasing ratio of Nu-wall/Nu-center is obtained. The increasing ratio for Nusselt number ranged from 3 to 18%. However, the use of twisted tape inserts is not beneficial for energy saving. The thermo-hydraulic performance parameters for convective heat transfer of helium gas flowing in a circular tube are below unity for the calculated Reynolds region.
url https://doi.org/10.1038/s41598-021-86285-0
work_keys_str_mv AT liwang theeffectofoffcenterplacementoftwistedtapeonflowandheattransfercharacteristicsinacirculartube
AT peiyongni theeffectofoffcenterplacementoftwistedtapeonflowandheattransfercharacteristicsinacirculartube
AT guannanxi theeffectofoffcenterplacementoftwistedtapeonflowandheattransfercharacteristicsinacirculartube
AT liwang effectofoffcenterplacementoftwistedtapeonflowandheattransfercharacteristicsinacirculartube
AT peiyongni effectofoffcenterplacementoftwistedtapeonflowandheattransfercharacteristicsinacirculartube
AT guannanxi effectofoffcenterplacementoftwistedtapeonflowandheattransfercharacteristicsinacirculartube
_version_ 1724199851922554880