Evaluation of transmitral pressure gradients in the intraoperative echocardiographic diagnosis of mitral stenosis after mitral valve repair.
OBJECTIVE: Acute mitral stenosis (MS) following mitral valve (MV) repair is a rare but severe complication. We hypothesize that intraoperative echocardiography can be utilized to diagnose iatrogenic MS immediately after MV repair. METHODS: The medical records of 552 consecutive patients undergoing M...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Public Library of Science (PLoS)
2011-01-01
|
Series: | PLoS ONE |
Online Access: | http://europepmc.org/articles/PMC3210749?pdf=render |
id |
doaj-6824e4fa1cbe4dc58b1d8102bab87092 |
---|---|
record_format |
Article |
spelling |
doaj-6824e4fa1cbe4dc58b1d8102bab870922020-11-25T00:11:44ZengPublic Library of Science (PLoS)PLoS ONE1932-62032011-01-01611e2655910.1371/journal.pone.0026559Evaluation of transmitral pressure gradients in the intraoperative echocardiographic diagnosis of mitral stenosis after mitral valve repair.Ann K RiegelRaila BuschScott SegalJohn A FoxHolger K EltzschigStanton K ShernanOBJECTIVE: Acute mitral stenosis (MS) following mitral valve (MV) repair is a rare but severe complication. We hypothesize that intraoperative echocardiography can be utilized to diagnose iatrogenic MS immediately after MV repair. METHODS: The medical records of 552 consecutive patients undergoing MV repair at a single institution were reviewed. Post-cardiopulmonary bypass peak and mean transmitral pressure gradients (TMPG), and pressure half time (PHT) were obtained from intraoperative transesophageal echocardiographic (TEE) examinations in each patient. RESULTS: Nine patients (9/552 = 1.6%) received a reoperation for primary MS, prior to hospital discharge. Interestingly, all of these patients already showed intraoperative post-CPB mean and peak TMPGs that were significantly higher compared to values for those who did not: 10.7±4.8 mmHg vs 2.9±1.6 mmHg; p<0.0001 and 22.9±7.9 mmHg vs 7.6±3.7 mmHg; p<0.0001, respectively. However, PHT varied considerably (87±37 ms; range: 20-439 ms) within the entire population, and only weakly predicted the requirement for reoperation (113±56 vs. 87±37 ms, p = 0.034). Receiver operating characteristic curves showed strong discriminating ability for mean gradients (AUC = 0.993) and peak gradients (area under the curve, AUC = 0.996), but poor performance for PHT (AUC = 0.640). A value of ≥7 mmHg for mean, and ≥17 mmHg for peak TMPG, best separated patients who required reoperation for MS from those who did not. CONCLUSIONS: Intraoperative TEE diagnosis of a peak TMPG ≥17 mmHg or mean TMPG ≥7 mmHg immediately following CPB are suggestive of clinically relevant MS after MV repair.http://europepmc.org/articles/PMC3210749?pdf=render |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Ann K Riegel Raila Busch Scott Segal John A Fox Holger K Eltzschig Stanton K Shernan |
spellingShingle |
Ann K Riegel Raila Busch Scott Segal John A Fox Holger K Eltzschig Stanton K Shernan Evaluation of transmitral pressure gradients in the intraoperative echocardiographic diagnosis of mitral stenosis after mitral valve repair. PLoS ONE |
author_facet |
Ann K Riegel Raila Busch Scott Segal John A Fox Holger K Eltzschig Stanton K Shernan |
author_sort |
Ann K Riegel |
title |
Evaluation of transmitral pressure gradients in the intraoperative echocardiographic diagnosis of mitral stenosis after mitral valve repair. |
title_short |
Evaluation of transmitral pressure gradients in the intraoperative echocardiographic diagnosis of mitral stenosis after mitral valve repair. |
title_full |
Evaluation of transmitral pressure gradients in the intraoperative echocardiographic diagnosis of mitral stenosis after mitral valve repair. |
title_fullStr |
Evaluation of transmitral pressure gradients in the intraoperative echocardiographic diagnosis of mitral stenosis after mitral valve repair. |
title_full_unstemmed |
Evaluation of transmitral pressure gradients in the intraoperative echocardiographic diagnosis of mitral stenosis after mitral valve repair. |
title_sort |
evaluation of transmitral pressure gradients in the intraoperative echocardiographic diagnosis of mitral stenosis after mitral valve repair. |
publisher |
Public Library of Science (PLoS) |
series |
PLoS ONE |
issn |
1932-6203 |
publishDate |
2011-01-01 |
description |
OBJECTIVE: Acute mitral stenosis (MS) following mitral valve (MV) repair is a rare but severe complication. We hypothesize that intraoperative echocardiography can be utilized to diagnose iatrogenic MS immediately after MV repair. METHODS: The medical records of 552 consecutive patients undergoing MV repair at a single institution were reviewed. Post-cardiopulmonary bypass peak and mean transmitral pressure gradients (TMPG), and pressure half time (PHT) were obtained from intraoperative transesophageal echocardiographic (TEE) examinations in each patient. RESULTS: Nine patients (9/552 = 1.6%) received a reoperation for primary MS, prior to hospital discharge. Interestingly, all of these patients already showed intraoperative post-CPB mean and peak TMPGs that were significantly higher compared to values for those who did not: 10.7±4.8 mmHg vs 2.9±1.6 mmHg; p<0.0001 and 22.9±7.9 mmHg vs 7.6±3.7 mmHg; p<0.0001, respectively. However, PHT varied considerably (87±37 ms; range: 20-439 ms) within the entire population, and only weakly predicted the requirement for reoperation (113±56 vs. 87±37 ms, p = 0.034). Receiver operating characteristic curves showed strong discriminating ability for mean gradients (AUC = 0.993) and peak gradients (area under the curve, AUC = 0.996), but poor performance for PHT (AUC = 0.640). A value of ≥7 mmHg for mean, and ≥17 mmHg for peak TMPG, best separated patients who required reoperation for MS from those who did not. CONCLUSIONS: Intraoperative TEE diagnosis of a peak TMPG ≥17 mmHg or mean TMPG ≥7 mmHg immediately following CPB are suggestive of clinically relevant MS after MV repair. |
url |
http://europepmc.org/articles/PMC3210749?pdf=render |
work_keys_str_mv |
AT annkriegel evaluationoftransmitralpressuregradientsintheintraoperativeechocardiographicdiagnosisofmitralstenosisaftermitralvalverepair AT railabusch evaluationoftransmitralpressuregradientsintheintraoperativeechocardiographicdiagnosisofmitralstenosisaftermitralvalverepair AT scottsegal evaluationoftransmitralpressuregradientsintheintraoperativeechocardiographicdiagnosisofmitralstenosisaftermitralvalverepair AT johnafox evaluationoftransmitralpressuregradientsintheintraoperativeechocardiographicdiagnosisofmitralstenosisaftermitralvalverepair AT holgerkeltzschig evaluationoftransmitralpressuregradientsintheintraoperativeechocardiographicdiagnosisofmitralstenosisaftermitralvalverepair AT stantonkshernan evaluationoftransmitralpressuregradientsintheintraoperativeechocardiographicdiagnosisofmitralstenosisaftermitralvalverepair |
_version_ |
1725402569321218048 |