Evaluation of transmitral pressure gradients in the intraoperative echocardiographic diagnosis of mitral stenosis after mitral valve repair.

OBJECTIVE: Acute mitral stenosis (MS) following mitral valve (MV) repair is a rare but severe complication. We hypothesize that intraoperative echocardiography can be utilized to diagnose iatrogenic MS immediately after MV repair. METHODS: The medical records of 552 consecutive patients undergoing M...

Full description

Bibliographic Details
Main Authors: Ann K Riegel, Raila Busch, Scott Segal, John A Fox, Holger K Eltzschig, Stanton K Shernan
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2011-01-01
Series:PLoS ONE
Online Access:http://europepmc.org/articles/PMC3210749?pdf=render
Description
Summary:OBJECTIVE: Acute mitral stenosis (MS) following mitral valve (MV) repair is a rare but severe complication. We hypothesize that intraoperative echocardiography can be utilized to diagnose iatrogenic MS immediately after MV repair. METHODS: The medical records of 552 consecutive patients undergoing MV repair at a single institution were reviewed. Post-cardiopulmonary bypass peak and mean transmitral pressure gradients (TMPG), and pressure half time (PHT) were obtained from intraoperative transesophageal echocardiographic (TEE) examinations in each patient. RESULTS: Nine patients (9/552 = 1.6%) received a reoperation for primary MS, prior to hospital discharge. Interestingly, all of these patients already showed intraoperative post-CPB mean and peak TMPGs that were significantly higher compared to values for those who did not: 10.7±4.8 mmHg vs 2.9±1.6 mmHg; p<0.0001 and 22.9±7.9 mmHg vs 7.6±3.7 mmHg; p<0.0001, respectively. However, PHT varied considerably (87±37 ms; range: 20-439 ms) within the entire population, and only weakly predicted the requirement for reoperation (113±56 vs. 87±37 ms, p = 0.034). Receiver operating characteristic curves showed strong discriminating ability for mean gradients (AUC = 0.993) and peak gradients (area under the curve, AUC = 0.996), but poor performance for PHT (AUC = 0.640). A value of ≥7 mmHg for mean, and ≥17 mmHg for peak TMPG, best separated patients who required reoperation for MS from those who did not. CONCLUSIONS: Intraoperative TEE diagnosis of a peak TMPG ≥17 mmHg or mean TMPG ≥7 mmHg immediately following CPB are suggestive of clinically relevant MS after MV repair.
ISSN:1932-6203