Optimization Design of Industrial Water Supply Pump Station Considering the Influence of Atmospheric Temperature on Operation Cost
Pump type selection at a pump station affects not only the hardware investment but also the operating efficiency. The influence of atmospheric temperature on water consumption was not considered in existing studies. This article considers the uncertainty of water consumption caused by temperature as...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
IEEE
2020-01-01
|
Series: | IEEE Access |
Subjects: | |
Online Access: | https://ieeexplore.ieee.org/document/9184878/ |
id |
doaj-67df20c606684c88b5b832b5358cfe7d |
---|---|
record_format |
Article |
spelling |
doaj-67df20c606684c88b5b832b5358cfe7d2021-03-30T03:31:40ZengIEEEIEEE Access2169-35362020-01-01816170216171210.1109/ACCESS.2020.30213049184878Optimization Design of Industrial Water Supply Pump Station Considering the Influence of Atmospheric Temperature on Operation CostMingxing Jia0https://orcid.org/0000-0002-3876-1804Jialun Zhang1https://orcid.org/0000-0002-6048-5711Yuemei Xu2https://orcid.org/0000-0003-3305-0357College of Information Science and Engineering, Northeastern University, Shenyang, ChinaCollege of Information Science and Engineering, Northeastern University, Shenyang, ChinaCollege of Information Science and Engineering, Northeastern University, Shenyang, ChinaPump type selection at a pump station affects not only the hardware investment but also the operating efficiency. The influence of atmospheric temperature on water consumption was not considered in existing studies. This article considers the uncertainty of water consumption caused by temperature as well as the configuration and operation schedule of the pump station under various working conditions. The purpose of the present paper is to achieve the minimum annual investment and operation cost of the pump station. Taking a steel plant as an example, this article analyzes the possible working conditions of cooling water in the plant, establishes the annual minimum cost objective function of the optimal design, and sets the constraint conditions. The decision variables include the selection of overall pump type and optimal operation of the pump station under different working conditions. Finally, the mathematical model of the optimal design of a water supply pump station is given. The results show that when considering the influence of temperature on water consumption, the annual comprehensive cost is reduced, the optimization effect is obvious, and a good practical effect is achieved.https://ieeexplore.ieee.org/document/9184878/Water supply pump stationtemperatureuncertain conditionsoptimization design |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Mingxing Jia Jialun Zhang Yuemei Xu |
spellingShingle |
Mingxing Jia Jialun Zhang Yuemei Xu Optimization Design of Industrial Water Supply Pump Station Considering the Influence of Atmospheric Temperature on Operation Cost IEEE Access Water supply pump station temperature uncertain conditions optimization design |
author_facet |
Mingxing Jia Jialun Zhang Yuemei Xu |
author_sort |
Mingxing Jia |
title |
Optimization Design of Industrial Water Supply Pump Station Considering the Influence of Atmospheric Temperature on Operation Cost |
title_short |
Optimization Design of Industrial Water Supply Pump Station Considering the Influence of Atmospheric Temperature on Operation Cost |
title_full |
Optimization Design of Industrial Water Supply Pump Station Considering the Influence of Atmospheric Temperature on Operation Cost |
title_fullStr |
Optimization Design of Industrial Water Supply Pump Station Considering the Influence of Atmospheric Temperature on Operation Cost |
title_full_unstemmed |
Optimization Design of Industrial Water Supply Pump Station Considering the Influence of Atmospheric Temperature on Operation Cost |
title_sort |
optimization design of industrial water supply pump station considering the influence of atmospheric temperature on operation cost |
publisher |
IEEE |
series |
IEEE Access |
issn |
2169-3536 |
publishDate |
2020-01-01 |
description |
Pump type selection at a pump station affects not only the hardware investment but also the operating efficiency. The influence of atmospheric temperature on water consumption was not considered in existing studies. This article considers the uncertainty of water consumption caused by temperature as well as the configuration and operation schedule of the pump station under various working conditions. The purpose of the present paper is to achieve the minimum annual investment and operation cost of the pump station. Taking a steel plant as an example, this article analyzes the possible working conditions of cooling water in the plant, establishes the annual minimum cost objective function of the optimal design, and sets the constraint conditions. The decision variables include the selection of overall pump type and optimal operation of the pump station under different working conditions. Finally, the mathematical model of the optimal design of a water supply pump station is given. The results show that when considering the influence of temperature on water consumption, the annual comprehensive cost is reduced, the optimization effect is obvious, and a good practical effect is achieved. |
topic |
Water supply pump station temperature uncertain conditions optimization design |
url |
https://ieeexplore.ieee.org/document/9184878/ |
work_keys_str_mv |
AT mingxingjia optimizationdesignofindustrialwatersupplypumpstationconsideringtheinfluenceofatmospherictemperatureonoperationcost AT jialunzhang optimizationdesignofindustrialwatersupplypumpstationconsideringtheinfluenceofatmospherictemperatureonoperationcost AT yuemeixu optimizationdesignofindustrialwatersupplypumpstationconsideringtheinfluenceofatmospherictemperatureonoperationcost |
_version_ |
1724183292049096704 |