Rancang Bangun Kendali Sekuen untuk Sambungan Jala-Jala Listrik Menggunakan Cycloconverter

<p>This developed cycloconverter circuit simulates grid connector circuit using two function generators, which substitute AC power. The first function generator was used to represent input wave from PLN with 50 Hz frequency. The other function generator was used to represent input wave from ne...

Full description

Bibliographic Details
Main Authors: Yuliardi Erdani, Aris Eko Setiawan, Maulana Aria Pratama
Format: Article
Language:English
Published: Indonesian Institute of Sciences 2012-03-01
Series:Journal of Mechatronics, Electrical Power, and Vehicular Technology
Subjects:
Online Access:http://mevjournal.com/index.php/mev/article/view/12
id doaj-67c06fc675d14dbca3c4d65da6b8986a
record_format Article
spelling doaj-67c06fc675d14dbca3c4d65da6b8986a2020-11-25T03:44:48ZengIndonesian Institute of SciencesJournal of Mechatronics, Electrical Power, and Vehicular Technology2087-33792088-69852012-03-0112697410.14203/j.mev.2010.v1.69-7410Rancang Bangun Kendali Sekuen untuk Sambungan Jala-Jala Listrik Menggunakan CycloconverterYuliardi Erdani0Aris Eko Setiawan1Maulana Aria Pratama2Jurusan Teknik Otomasi Manufaktur dan Mekatronika - Politeknik Manufaktur Negeri Bandung, Jl. Kanayakan No. 21, Bandung, Jawa Barat 40275Jurusan Teknik Otomasi Manufaktur dan Mekatronika - Politeknik Manufaktur Negeri Bandung, Jl. Kanayakan No. 21, Bandung, Jawa Barat 40275Jurusan Teknik Otomasi Manufaktur dan Mekatronika - Politeknik Manufaktur Negeri Bandung, Jl. Kanayakan No. 21, Bandung, Jawa Barat 40275<p>This developed cycloconverter circuit simulates grid connector circuit using two function generators, which substitute AC power. The first function generator was used to represent input wave from PLN with 50 Hz frequency. The other function generator was used to represent input wave from new generator with 10-90 Hz frequency. Such initial condition enabled us to control the frequency increase from 10Hz – 40Hz to 50Hz and decrease from 60Hz – 90Hz to 50Hz. This cycloconverter used trigger circuit to activate its electrical components. The trigger circuit contains trigger parts such as thyristor and MOSFET. All hardware components in this circuit were controlled by microcontroller ATMega 8535. This controller manages all trigger circuits that were needed by cycloconverter. The experiment result shows that the cycloconverter wasable to modify frequency and phase angle, so that it enabled the connection to the electrical grid.</p>http://mevjournal.com/index.php/mev/article/view/12CycloconverterElectrical Grid ConnectionPower Electronic
collection DOAJ
language English
format Article
sources DOAJ
author Yuliardi Erdani
Aris Eko Setiawan
Maulana Aria Pratama
spellingShingle Yuliardi Erdani
Aris Eko Setiawan
Maulana Aria Pratama
Rancang Bangun Kendali Sekuen untuk Sambungan Jala-Jala Listrik Menggunakan Cycloconverter
Journal of Mechatronics, Electrical Power, and Vehicular Technology
Cycloconverter
Electrical Grid Connection
Power Electronic
author_facet Yuliardi Erdani
Aris Eko Setiawan
Maulana Aria Pratama
author_sort Yuliardi Erdani
title Rancang Bangun Kendali Sekuen untuk Sambungan Jala-Jala Listrik Menggunakan Cycloconverter
title_short Rancang Bangun Kendali Sekuen untuk Sambungan Jala-Jala Listrik Menggunakan Cycloconverter
title_full Rancang Bangun Kendali Sekuen untuk Sambungan Jala-Jala Listrik Menggunakan Cycloconverter
title_fullStr Rancang Bangun Kendali Sekuen untuk Sambungan Jala-Jala Listrik Menggunakan Cycloconverter
title_full_unstemmed Rancang Bangun Kendali Sekuen untuk Sambungan Jala-Jala Listrik Menggunakan Cycloconverter
title_sort rancang bangun kendali sekuen untuk sambungan jala-jala listrik menggunakan cycloconverter
publisher Indonesian Institute of Sciences
series Journal of Mechatronics, Electrical Power, and Vehicular Technology
issn 2087-3379
2088-6985
publishDate 2012-03-01
description <p>This developed cycloconverter circuit simulates grid connector circuit using two function generators, which substitute AC power. The first function generator was used to represent input wave from PLN with 50 Hz frequency. The other function generator was used to represent input wave from new generator with 10-90 Hz frequency. Such initial condition enabled us to control the frequency increase from 10Hz – 40Hz to 50Hz and decrease from 60Hz – 90Hz to 50Hz. This cycloconverter used trigger circuit to activate its electrical components. The trigger circuit contains trigger parts such as thyristor and MOSFET. All hardware components in this circuit were controlled by microcontroller ATMega 8535. This controller manages all trigger circuits that were needed by cycloconverter. The experiment result shows that the cycloconverter wasable to modify frequency and phase angle, so that it enabled the connection to the electrical grid.</p>
topic Cycloconverter
Electrical Grid Connection
Power Electronic
url http://mevjournal.com/index.php/mev/article/view/12
work_keys_str_mv AT yuliardierdani rancangbangunkendalisekuenuntuksambunganjalajalalistrikmenggunakancycloconverter
AT arisekosetiawan rancangbangunkendalisekuenuntuksambunganjalajalalistrikmenggunakancycloconverter
AT maulanaariapratama rancangbangunkendalisekuenuntuksambunganjalajalalistrikmenggunakancycloconverter
_version_ 1724512688792403968