Rancang Bangun Kendali Sekuen untuk Sambungan Jala-Jala Listrik Menggunakan Cycloconverter
<p>This developed cycloconverter circuit simulates grid connector circuit using two function generators, which substitute AC power. The first function generator was used to represent input wave from PLN with 50 Hz frequency. The other function generator was used to represent input wave from ne...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Indonesian Institute of Sciences
2012-03-01
|
Series: | Journal of Mechatronics, Electrical Power, and Vehicular Technology |
Subjects: | |
Online Access: | http://mevjournal.com/index.php/mev/article/view/12 |
id |
doaj-67c06fc675d14dbca3c4d65da6b8986a |
---|---|
record_format |
Article |
spelling |
doaj-67c06fc675d14dbca3c4d65da6b8986a2020-11-25T03:44:48ZengIndonesian Institute of SciencesJournal of Mechatronics, Electrical Power, and Vehicular Technology2087-33792088-69852012-03-0112697410.14203/j.mev.2010.v1.69-7410Rancang Bangun Kendali Sekuen untuk Sambungan Jala-Jala Listrik Menggunakan CycloconverterYuliardi Erdani0Aris Eko Setiawan1Maulana Aria Pratama2Jurusan Teknik Otomasi Manufaktur dan Mekatronika - Politeknik Manufaktur Negeri Bandung, Jl. Kanayakan No. 21, Bandung, Jawa Barat 40275Jurusan Teknik Otomasi Manufaktur dan Mekatronika - Politeknik Manufaktur Negeri Bandung, Jl. Kanayakan No. 21, Bandung, Jawa Barat 40275Jurusan Teknik Otomasi Manufaktur dan Mekatronika - Politeknik Manufaktur Negeri Bandung, Jl. Kanayakan No. 21, Bandung, Jawa Barat 40275<p>This developed cycloconverter circuit simulates grid connector circuit using two function generators, which substitute AC power. The first function generator was used to represent input wave from PLN with 50 Hz frequency. The other function generator was used to represent input wave from new generator with 10-90 Hz frequency. Such initial condition enabled us to control the frequency increase from 10Hz – 40Hz to 50Hz and decrease from 60Hz – 90Hz to 50Hz. This cycloconverter used trigger circuit to activate its electrical components. The trigger circuit contains trigger parts such as thyristor and MOSFET. All hardware components in this circuit were controlled by microcontroller ATMega 8535. This controller manages all trigger circuits that were needed by cycloconverter. The experiment result shows that the cycloconverter wasable to modify frequency and phase angle, so that it enabled the connection to the electrical grid.</p>http://mevjournal.com/index.php/mev/article/view/12CycloconverterElectrical Grid ConnectionPower Electronic |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Yuliardi Erdani Aris Eko Setiawan Maulana Aria Pratama |
spellingShingle |
Yuliardi Erdani Aris Eko Setiawan Maulana Aria Pratama Rancang Bangun Kendali Sekuen untuk Sambungan Jala-Jala Listrik Menggunakan Cycloconverter Journal of Mechatronics, Electrical Power, and Vehicular Technology Cycloconverter Electrical Grid Connection Power Electronic |
author_facet |
Yuliardi Erdani Aris Eko Setiawan Maulana Aria Pratama |
author_sort |
Yuliardi Erdani |
title |
Rancang Bangun Kendali Sekuen untuk Sambungan Jala-Jala Listrik Menggunakan Cycloconverter |
title_short |
Rancang Bangun Kendali Sekuen untuk Sambungan Jala-Jala Listrik Menggunakan Cycloconverter |
title_full |
Rancang Bangun Kendali Sekuen untuk Sambungan Jala-Jala Listrik Menggunakan Cycloconverter |
title_fullStr |
Rancang Bangun Kendali Sekuen untuk Sambungan Jala-Jala Listrik Menggunakan Cycloconverter |
title_full_unstemmed |
Rancang Bangun Kendali Sekuen untuk Sambungan Jala-Jala Listrik Menggunakan Cycloconverter |
title_sort |
rancang bangun kendali sekuen untuk sambungan jala-jala listrik menggunakan cycloconverter |
publisher |
Indonesian Institute of Sciences |
series |
Journal of Mechatronics, Electrical Power, and Vehicular Technology |
issn |
2087-3379 2088-6985 |
publishDate |
2012-03-01 |
description |
<p>This developed cycloconverter circuit simulates grid connector circuit using two function generators, which substitute AC power. The first function generator was used to represent input wave from PLN with 50 Hz frequency. The other function generator was used to represent input wave from new generator with 10-90 Hz frequency. Such initial condition enabled us to control the frequency increase from 10Hz – 40Hz to 50Hz and decrease from 60Hz – 90Hz to 50Hz. This cycloconverter used trigger circuit to activate its electrical components. The trigger circuit contains trigger parts such as thyristor and MOSFET. All hardware components in this circuit were controlled by microcontroller ATMega 8535. This controller manages all trigger circuits that were needed by cycloconverter. The experiment result shows that the cycloconverter wasable to modify frequency and phase angle, so that it enabled the connection to the electrical grid.</p> |
topic |
Cycloconverter Electrical Grid Connection Power Electronic |
url |
http://mevjournal.com/index.php/mev/article/view/12 |
work_keys_str_mv |
AT yuliardierdani rancangbangunkendalisekuenuntuksambunganjalajalalistrikmenggunakancycloconverter AT arisekosetiawan rancangbangunkendalisekuenuntuksambunganjalajalalistrikmenggunakancycloconverter AT maulanaariapratama rancangbangunkendalisekuenuntuksambunganjalajalalistrikmenggunakancycloconverter |
_version_ |
1724512688792403968 |