A Comparison of Intra-Observer and Inter-Observer Reliability of Plain Radiographs, Standard Computed Tomography Scans and Mobile Computed Tomography Scans in the Assessment of Distal Radius Fractures: A Cadaveric Study

Objective: Diagnosis of a distal end radius fracture relies on various imaging studies. However, the relative usefulness of these studies is still a matter of some controversy. The aim of this study was to compare the intra-observer and inter-observer reliability of plain radiographs, standard compu...

Full description

Bibliographic Details
Main Authors: Sitthiphong Suwannaphisit, Saowapar Yoykaew, Chitchaya Suwanraksa, Varah Yuenyongviwat, Porames Suwanno, Sittichoke Anuntaseree
Format: Article
Language:English
Published: Prince of Songkla University 2020-01-01
Series:Journal of Health Science and Medical Research (JHSMR)
Subjects:
Online Access:https://www.jhsmr.org/index.php/jhsmr/article/view/78
id doaj-679e336c726846e289e606a2c941f38c
record_format Article
spelling doaj-679e336c726846e289e606a2c941f38c2020-11-25T01:44:29ZengPrince of Songkla UniversityJournal of Health Science and Medical Research (JHSMR)2586-99812630-05592020-01-01381535910.31584/jhsmr.20207891A Comparison of Intra-Observer and Inter-Observer Reliability of Plain Radiographs, Standard Computed Tomography Scans and Mobile Computed Tomography Scans in the Assessment of Distal Radius Fractures: A Cadaveric StudySitthiphong Suwannaphisit0Saowapar Yoykaew1Chitchaya Suwanraksa2Varah Yuenyongviwat3Porames Suwanno4Sittichoke Anuntaseree5Department of Orthopedics, Faculty of Medicine, Prince of Songkla University, Hat Yai, Songkhla 90110,Department of Orthopedics, Faculty of Medicine, Prince of Songkla University, Hat Yai, Songkhla 90110,Department of Orthopedics, Faculty of Medicine, Prince of Songkla University, Hat Yai, Songkhla 90110,Department of Orthopedics, Faculty of Medicine, Prince of Songkla University, Hat Yai, Songkhla 90110,Department of Orthopedics, Faculty of Medicine, Prince of Songkla University, Hat Yai, Songkhla 90110,Department of Orthopedics, Faculty of Medicine, Prince of Songkla University, Hat Yai, Songkhla 90110,Objective: Diagnosis of a distal end radius fracture relies on various imaging studies. However, the relative usefulness of these studies is still a matter of some controversy. The aim of this study was to compare the intra-observer and inter-observer reliability of plain radiographs, standard computed tomography (CT) scans and mobile CT scans in the assessment of distal radius fractures as categorized by the Fernandez classification method. The secondary objective was to compare the dosages of radiation between the different imaging modalities. Material and Methods: Sixteen fresh cadaveric wrist bones were used in this experimental study. The desired fractures were created in the bones to mimic Fernandez types I-V fractures and plain radiographs were taken in 4 views. Standard CT and mobile CT scans were also taken with the fractured bones in the same four positions. Interobserver reliability was assessed using Kappa statistics to determine the diagnostic consistency among the nine observers. Inter-observer agreement was assessed based on the Fernandez classification system diagnoses. Results: Overall, the inter-observer agreement was substantial for the Fernandez classifications (Kappa range 0.636 0.727) in all types of imaging. For intra-observer agreement, the analysis found higher agreement for both standard CT scans and mobile CT scans. The standard CT images imparted a higher average dose of radiation than both the mobile CT scans and the plain radiographs. Conclusion: The mobile CT scan can provide an alternative imaging method for precise diagnosis of distal end radius fractures, with the additional benefits of mobility and lower radiation exposure.https://www.jhsmr.org/index.php/jhsmr/article/view/78computed tomographydistal radius fracturesfernandez classificationimaging
collection DOAJ
language English
format Article
sources DOAJ
author Sitthiphong Suwannaphisit
Saowapar Yoykaew
Chitchaya Suwanraksa
Varah Yuenyongviwat
Porames Suwanno
Sittichoke Anuntaseree
spellingShingle Sitthiphong Suwannaphisit
Saowapar Yoykaew
Chitchaya Suwanraksa
Varah Yuenyongviwat
Porames Suwanno
Sittichoke Anuntaseree
A Comparison of Intra-Observer and Inter-Observer Reliability of Plain Radiographs, Standard Computed Tomography Scans and Mobile Computed Tomography Scans in the Assessment of Distal Radius Fractures: A Cadaveric Study
Journal of Health Science and Medical Research (JHSMR)
computed tomography
distal radius fractures
fernandez classification
imaging
author_facet Sitthiphong Suwannaphisit
Saowapar Yoykaew
Chitchaya Suwanraksa
Varah Yuenyongviwat
Porames Suwanno
Sittichoke Anuntaseree
author_sort Sitthiphong Suwannaphisit
title A Comparison of Intra-Observer and Inter-Observer Reliability of Plain Radiographs, Standard Computed Tomography Scans and Mobile Computed Tomography Scans in the Assessment of Distal Radius Fractures: A Cadaveric Study
title_short A Comparison of Intra-Observer and Inter-Observer Reliability of Plain Radiographs, Standard Computed Tomography Scans and Mobile Computed Tomography Scans in the Assessment of Distal Radius Fractures: A Cadaveric Study
title_full A Comparison of Intra-Observer and Inter-Observer Reliability of Plain Radiographs, Standard Computed Tomography Scans and Mobile Computed Tomography Scans in the Assessment of Distal Radius Fractures: A Cadaveric Study
title_fullStr A Comparison of Intra-Observer and Inter-Observer Reliability of Plain Radiographs, Standard Computed Tomography Scans and Mobile Computed Tomography Scans in the Assessment of Distal Radius Fractures: A Cadaveric Study
title_full_unstemmed A Comparison of Intra-Observer and Inter-Observer Reliability of Plain Radiographs, Standard Computed Tomography Scans and Mobile Computed Tomography Scans in the Assessment of Distal Radius Fractures: A Cadaveric Study
title_sort comparison of intra-observer and inter-observer reliability of plain radiographs, standard computed tomography scans and mobile computed tomography scans in the assessment of distal radius fractures: a cadaveric study
publisher Prince of Songkla University
series Journal of Health Science and Medical Research (JHSMR)
issn 2586-9981
2630-0559
publishDate 2020-01-01
description Objective: Diagnosis of a distal end radius fracture relies on various imaging studies. However, the relative usefulness of these studies is still a matter of some controversy. The aim of this study was to compare the intra-observer and inter-observer reliability of plain radiographs, standard computed tomography (CT) scans and mobile CT scans in the assessment of distal radius fractures as categorized by the Fernandez classification method. The secondary objective was to compare the dosages of radiation between the different imaging modalities. Material and Methods: Sixteen fresh cadaveric wrist bones were used in this experimental study. The desired fractures were created in the bones to mimic Fernandez types I-V fractures and plain radiographs were taken in 4 views. Standard CT and mobile CT scans were also taken with the fractured bones in the same four positions. Interobserver reliability was assessed using Kappa statistics to determine the diagnostic consistency among the nine observers. Inter-observer agreement was assessed based on the Fernandez classification system diagnoses. Results: Overall, the inter-observer agreement was substantial for the Fernandez classifications (Kappa range 0.636 0.727) in all types of imaging. For intra-observer agreement, the analysis found higher agreement for both standard CT scans and mobile CT scans. The standard CT images imparted a higher average dose of radiation than both the mobile CT scans and the plain radiographs. Conclusion: The mobile CT scan can provide an alternative imaging method for precise diagnosis of distal end radius fractures, with the additional benefits of mobility and lower radiation exposure.
topic computed tomography
distal radius fractures
fernandez classification
imaging
url https://www.jhsmr.org/index.php/jhsmr/article/view/78
work_keys_str_mv AT sitthiphongsuwannaphisit acomparisonofintraobserverandinterobserverreliabilityofplainradiographsstandardcomputedtomographyscansandmobilecomputedtomographyscansintheassessmentofdistalradiusfracturesacadavericstudy
AT saowaparyoykaew acomparisonofintraobserverandinterobserverreliabilityofplainradiographsstandardcomputedtomographyscansandmobilecomputedtomographyscansintheassessmentofdistalradiusfracturesacadavericstudy
AT chitchayasuwanraksa acomparisonofintraobserverandinterobserverreliabilityofplainradiographsstandardcomputedtomographyscansandmobilecomputedtomographyscansintheassessmentofdistalradiusfracturesacadavericstudy
AT varahyuenyongviwat acomparisonofintraobserverandinterobserverreliabilityofplainradiographsstandardcomputedtomographyscansandmobilecomputedtomographyscansintheassessmentofdistalradiusfracturesacadavericstudy
AT poramessuwanno acomparisonofintraobserverandinterobserverreliabilityofplainradiographsstandardcomputedtomographyscansandmobilecomputedtomographyscansintheassessmentofdistalradiusfracturesacadavericstudy
AT sittichokeanuntaseree acomparisonofintraobserverandinterobserverreliabilityofplainradiographsstandardcomputedtomographyscansandmobilecomputedtomographyscansintheassessmentofdistalradiusfracturesacadavericstudy
AT sitthiphongsuwannaphisit comparisonofintraobserverandinterobserverreliabilityofplainradiographsstandardcomputedtomographyscansandmobilecomputedtomographyscansintheassessmentofdistalradiusfracturesacadavericstudy
AT saowaparyoykaew comparisonofintraobserverandinterobserverreliabilityofplainradiographsstandardcomputedtomographyscansandmobilecomputedtomographyscansintheassessmentofdistalradiusfracturesacadavericstudy
AT chitchayasuwanraksa comparisonofintraobserverandinterobserverreliabilityofplainradiographsstandardcomputedtomographyscansandmobilecomputedtomographyscansintheassessmentofdistalradiusfracturesacadavericstudy
AT varahyuenyongviwat comparisonofintraobserverandinterobserverreliabilityofplainradiographsstandardcomputedtomographyscansandmobilecomputedtomographyscansintheassessmentofdistalradiusfracturesacadavericstudy
AT poramessuwanno comparisonofintraobserverandinterobserverreliabilityofplainradiographsstandardcomputedtomographyscansandmobilecomputedtomographyscansintheassessmentofdistalradiusfracturesacadavericstudy
AT sittichokeanuntaseree comparisonofintraobserverandinterobserverreliabilityofplainradiographsstandardcomputedtomographyscansandmobilecomputedtomographyscansintheassessmentofdistalradiusfracturesacadavericstudy
_version_ 1725028307590709248