CONTACT INTERACTION INVESTIGATION OF TARGET END FACE OF ULTRASONIC CONVERTER INSTALLED ON PENDULUM SUSPENSION WITH RIGID BASIS

An investigation pertaining to contact interaction process of a target end face of the ultrasonic converter installed on pendulum suspension with a rigid basis is presented in the paper. The paper shows that substitution of traditionally applied precision rolling guides by a pendulum suspension of t...

Full description

Bibliographic Details
Main Authors: M. G. Kiselev, A. V. Drozdov, А. A. Novikov, A. A. Neskina, A. A. Stolarov
Format: Article
Language:Russian
Published: Belarusian National Technical University 2010-10-01
Series:Nauka i Tehnika
Online Access:https://sat.bntu.by/jour/article/view/502
id doaj-6783b7716f9b412ebbca1becf6e2d505
record_format Article
spelling doaj-6783b7716f9b412ebbca1becf6e2d5052021-07-29T08:29:29ZrusBelarusian National Technical UniversityNauka i Tehnika2227-10312414-03922010-10-01052731495CONTACT INTERACTION INVESTIGATION OF TARGET END FACE OF ULTRASONIC CONVERTER INSTALLED ON PENDULUM SUSPENSION WITH RIGID BASISM. G. Kiselev0A. V. Drozdov1А. A. Novikov2A. A. Neskina3A. A. Stolarov4Belarusian National Technical UniversityBelarusian National Technical UniversityBelarusian National Technical UniversityBelarusian National Technical UniversityBelarusian National Technical UniversityAn investigation pertaining to contact interaction process of a target end face of the ultrasonic converter installed on pendulum suspension with a rigid basis is presented in the paper. The paper shows that substitution of traditionally applied precision rolling guides by a pendulum suspension of the ultrasonic converter allows significantly to simplify a process equipment design. A calculative model for contact interaction of an end face of the ultrasonic converter installed on a pendulum suspension  with a rigid basis and scheme of a mathematical  pendulum  that  corresponds are proposed in the paper and they permit to investigate an influence of pendulum suspension parameters and its loading conditions on the operational mode of an acoustic oscillatory system. The paper contains analytical dependences that make it possible to calculate time and power parameters in contact interaction of a target end face of the ultrasonic converter installed on a pendulum suspension with a rigid basis. These dependences take into account an amplitude of ultrasonic oscillations, converter weight, pendulum length and an angle of its deviation. The paper reveals that the applica­tion of the pendulum suspension of the ultrasonic converter allows to ensure a vibrating impact (operational) mode of interaction of a converter target end face with a rigid basis surface. Design variants of the pendulum suspension of the ultra­sonic converter while using various elastic elements are proposed and analyzed in the paper and with due account of concrete processing conditions these variants allow to provide the required value of own oscillation frequency of an acoustic system and also to create necessary value of a preliminary tightness in it.https://sat.bntu.by/jour/article/view/502
collection DOAJ
language Russian
format Article
sources DOAJ
author M. G. Kiselev
A. V. Drozdov
А. A. Novikov
A. A. Neskina
A. A. Stolarov
spellingShingle M. G. Kiselev
A. V. Drozdov
А. A. Novikov
A. A. Neskina
A. A. Stolarov
CONTACT INTERACTION INVESTIGATION OF TARGET END FACE OF ULTRASONIC CONVERTER INSTALLED ON PENDULUM SUSPENSION WITH RIGID BASIS
Nauka i Tehnika
author_facet M. G. Kiselev
A. V. Drozdov
А. A. Novikov
A. A. Neskina
A. A. Stolarov
author_sort M. G. Kiselev
title CONTACT INTERACTION INVESTIGATION OF TARGET END FACE OF ULTRASONIC CONVERTER INSTALLED ON PENDULUM SUSPENSION WITH RIGID BASIS
title_short CONTACT INTERACTION INVESTIGATION OF TARGET END FACE OF ULTRASONIC CONVERTER INSTALLED ON PENDULUM SUSPENSION WITH RIGID BASIS
title_full CONTACT INTERACTION INVESTIGATION OF TARGET END FACE OF ULTRASONIC CONVERTER INSTALLED ON PENDULUM SUSPENSION WITH RIGID BASIS
title_fullStr CONTACT INTERACTION INVESTIGATION OF TARGET END FACE OF ULTRASONIC CONVERTER INSTALLED ON PENDULUM SUSPENSION WITH RIGID BASIS
title_full_unstemmed CONTACT INTERACTION INVESTIGATION OF TARGET END FACE OF ULTRASONIC CONVERTER INSTALLED ON PENDULUM SUSPENSION WITH RIGID BASIS
title_sort contact interaction investigation of target end face of ultrasonic converter installed on pendulum suspension with rigid basis
publisher Belarusian National Technical University
series Nauka i Tehnika
issn 2227-1031
2414-0392
publishDate 2010-10-01
description An investigation pertaining to contact interaction process of a target end face of the ultrasonic converter installed on pendulum suspension with a rigid basis is presented in the paper. The paper shows that substitution of traditionally applied precision rolling guides by a pendulum suspension of the ultrasonic converter allows significantly to simplify a process equipment design. A calculative model for contact interaction of an end face of the ultrasonic converter installed on a pendulum suspension  with a rigid basis and scheme of a mathematical  pendulum  that  corresponds are proposed in the paper and they permit to investigate an influence of pendulum suspension parameters and its loading conditions on the operational mode of an acoustic oscillatory system. The paper contains analytical dependences that make it possible to calculate time and power parameters in contact interaction of a target end face of the ultrasonic converter installed on a pendulum suspension with a rigid basis. These dependences take into account an amplitude of ultrasonic oscillations, converter weight, pendulum length and an angle of its deviation. The paper reveals that the applica­tion of the pendulum suspension of the ultrasonic converter allows to ensure a vibrating impact (operational) mode of interaction of a converter target end face with a rigid basis surface. Design variants of the pendulum suspension of the ultra­sonic converter while using various elastic elements are proposed and analyzed in the paper and with due account of concrete processing conditions these variants allow to provide the required value of own oscillation frequency of an acoustic system and also to create necessary value of a preliminary tightness in it.
url https://sat.bntu.by/jour/article/view/502
work_keys_str_mv AT mgkiselev contactinteractioninvestigationoftargetendfaceofultrasonicconverterinstalledonpendulumsuspensionwithrigidbasis
AT avdrozdov contactinteractioninvestigationoftargetendfaceofultrasonicconverterinstalledonpendulumsuspensionwithrigidbasis
AT aanovikov contactinteractioninvestigationoftargetendfaceofultrasonicconverterinstalledonpendulumsuspensionwithrigidbasis
AT aaneskina contactinteractioninvestigationoftargetendfaceofultrasonicconverterinstalledonpendulumsuspensionwithrigidbasis
AT aastolarov contactinteractioninvestigationoftargetendfaceofultrasonicconverterinstalledonpendulumsuspensionwithrigidbasis
_version_ 1721255652480778240