CONTACT INTERACTION INVESTIGATION OF TARGET END FACE OF ULTRASONIC CONVERTER INSTALLED ON PENDULUM SUSPENSION WITH RIGID BASIS
An investigation pertaining to contact interaction process of a target end face of the ultrasonic converter installed on pendulum suspension with a rigid basis is presented in the paper. The paper shows that substitution of traditionally applied precision rolling guides by a pendulum suspension of t...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | Russian |
Published: |
Belarusian National Technical University
2010-10-01
|
Series: | Nauka i Tehnika |
Online Access: | https://sat.bntu.by/jour/article/view/502 |
id |
doaj-6783b7716f9b412ebbca1becf6e2d505 |
---|---|
record_format |
Article |
spelling |
doaj-6783b7716f9b412ebbca1becf6e2d5052021-07-29T08:29:29ZrusBelarusian National Technical UniversityNauka i Tehnika2227-10312414-03922010-10-01052731495CONTACT INTERACTION INVESTIGATION OF TARGET END FACE OF ULTRASONIC CONVERTER INSTALLED ON PENDULUM SUSPENSION WITH RIGID BASISM. G. Kiselev0A. V. Drozdov1А. A. Novikov2A. A. Neskina3A. A. Stolarov4Belarusian National Technical UniversityBelarusian National Technical UniversityBelarusian National Technical UniversityBelarusian National Technical UniversityBelarusian National Technical UniversityAn investigation pertaining to contact interaction process of a target end face of the ultrasonic converter installed on pendulum suspension with a rigid basis is presented in the paper. The paper shows that substitution of traditionally applied precision rolling guides by a pendulum suspension of the ultrasonic converter allows significantly to simplify a process equipment design. A calculative model for contact interaction of an end face of the ultrasonic converter installed on a pendulum suspension with a rigid basis and scheme of a mathematical pendulum that corresponds are proposed in the paper and they permit to investigate an influence of pendulum suspension parameters and its loading conditions on the operational mode of an acoustic oscillatory system. The paper contains analytical dependences that make it possible to calculate time and power parameters in contact interaction of a target end face of the ultrasonic converter installed on a pendulum suspension with a rigid basis. These dependences take into account an amplitude of ultrasonic oscillations, converter weight, pendulum length and an angle of its deviation. The paper reveals that the application of the pendulum suspension of the ultrasonic converter allows to ensure a vibrating impact (operational) mode of interaction of a converter target end face with a rigid basis surface. Design variants of the pendulum suspension of the ultrasonic converter while using various elastic elements are proposed and analyzed in the paper and with due account of concrete processing conditions these variants allow to provide the required value of own oscillation frequency of an acoustic system and also to create necessary value of a preliminary tightness in it.https://sat.bntu.by/jour/article/view/502 |
collection |
DOAJ |
language |
Russian |
format |
Article |
sources |
DOAJ |
author |
M. G. Kiselev A. V. Drozdov А. A. Novikov A. A. Neskina A. A. Stolarov |
spellingShingle |
M. G. Kiselev A. V. Drozdov А. A. Novikov A. A. Neskina A. A. Stolarov CONTACT INTERACTION INVESTIGATION OF TARGET END FACE OF ULTRASONIC CONVERTER INSTALLED ON PENDULUM SUSPENSION WITH RIGID BASIS Nauka i Tehnika |
author_facet |
M. G. Kiselev A. V. Drozdov А. A. Novikov A. A. Neskina A. A. Stolarov |
author_sort |
M. G. Kiselev |
title |
CONTACT INTERACTION INVESTIGATION OF TARGET END FACE OF ULTRASONIC CONVERTER INSTALLED ON PENDULUM SUSPENSION WITH RIGID BASIS |
title_short |
CONTACT INTERACTION INVESTIGATION OF TARGET END FACE OF ULTRASONIC CONVERTER INSTALLED ON PENDULUM SUSPENSION WITH RIGID BASIS |
title_full |
CONTACT INTERACTION INVESTIGATION OF TARGET END FACE OF ULTRASONIC CONVERTER INSTALLED ON PENDULUM SUSPENSION WITH RIGID BASIS |
title_fullStr |
CONTACT INTERACTION INVESTIGATION OF TARGET END FACE OF ULTRASONIC CONVERTER INSTALLED ON PENDULUM SUSPENSION WITH RIGID BASIS |
title_full_unstemmed |
CONTACT INTERACTION INVESTIGATION OF TARGET END FACE OF ULTRASONIC CONVERTER INSTALLED ON PENDULUM SUSPENSION WITH RIGID BASIS |
title_sort |
contact interaction investigation of target end face of ultrasonic converter installed on pendulum suspension with rigid basis |
publisher |
Belarusian National Technical University |
series |
Nauka i Tehnika |
issn |
2227-1031 2414-0392 |
publishDate |
2010-10-01 |
description |
An investigation pertaining to contact interaction process of a target end face of the ultrasonic converter installed on pendulum suspension with a rigid basis is presented in the paper. The paper shows that substitution of traditionally applied precision rolling guides by a pendulum suspension of the ultrasonic converter allows significantly to simplify a process equipment design. A calculative model for contact interaction of an end face of the ultrasonic converter installed on a pendulum suspension with a rigid basis and scheme of a mathematical pendulum that corresponds are proposed in the paper and they permit to investigate an influence of pendulum suspension parameters and its loading conditions on the operational mode of an acoustic oscillatory system. The paper contains analytical dependences that make it possible to calculate time and power parameters in contact interaction of a target end face of the ultrasonic converter installed on a pendulum suspension with a rigid basis. These dependences take into account an amplitude of ultrasonic oscillations, converter weight, pendulum length and an angle of its deviation. The paper reveals that the application of the pendulum suspension of the ultrasonic converter allows to ensure a vibrating impact (operational) mode of interaction of a converter target end face with a rigid basis surface. Design variants of the pendulum suspension of the ultrasonic converter while using various elastic elements are proposed and analyzed in the paper and with due account of concrete processing conditions these variants allow to provide the required value of own oscillation frequency of an acoustic system and also to create necessary value of a preliminary tightness in it. |
url |
https://sat.bntu.by/jour/article/view/502 |
work_keys_str_mv |
AT mgkiselev contactinteractioninvestigationoftargetendfaceofultrasonicconverterinstalledonpendulumsuspensionwithrigidbasis AT avdrozdov contactinteractioninvestigationoftargetendfaceofultrasonicconverterinstalledonpendulumsuspensionwithrigidbasis AT aanovikov contactinteractioninvestigationoftargetendfaceofultrasonicconverterinstalledonpendulumsuspensionwithrigidbasis AT aaneskina contactinteractioninvestigationoftargetendfaceofultrasonicconverterinstalledonpendulumsuspensionwithrigidbasis AT aastolarov contactinteractioninvestigationoftargetendfaceofultrasonicconverterinstalledonpendulumsuspensionwithrigidbasis |
_version_ |
1721255652480778240 |