On-line estimations of delivered radiation doses in three-dimensional conformal radiotherapy treatments of carcinoma uterine cervix patients in linear accelerator

Transmission of radiation fluence through patient′s body has a correlation to the planned target dose. A method to estimate the delivered dose to target volumes was standardized using a beam level 0.6 cc ionization chamber (IC) positioned at electronic portal imaging device (EPID) plane from the mea...

Full description

Bibliographic Details
Main Authors: Suman Kumar Putha, P U Saxena, S Banerjee, Challapalli Srinivas, B M Vadhiraja, Ramamoorthy Ravichandran, Mary Joan, K Dinesh Pai
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2016-01-01
Series:Journal of Medical Physics
Subjects:
Online Access:http://www.jmp.org.in/article.asp?issn=0971-6203;year=2016;volume=41;issue=4;spage=224;epage=233;aulast=Putha
id doaj-660c5cef86d54712a176085f3c426811
record_format Article
spelling doaj-660c5cef86d54712a176085f3c4268112020-11-24T22:37:39ZengWolters Kluwer Medknow PublicationsJournal of Medical Physics0971-62031998-39132016-01-0141422423310.4103/0971-6203.195186On-line estimations of delivered radiation doses in three-dimensional conformal radiotherapy treatments of carcinoma uterine cervix patients in linear acceleratorSuman Kumar PuthaP U SaxenaS BanerjeeChallapalli SrinivasB M VadhirajaRamamoorthy RavichandranMary JoanK Dinesh PaiTransmission of radiation fluence through patient′s body has a correlation to the planned target dose. A method to estimate the delivered dose to target volumes was standardized using a beam level 0.6 cc ionization chamber (IC) positioned at electronic portal imaging device (EPID) plane from the measured transit signal (S t ) in patients with cancer of uterine cervix treated with three-dimensional conformal radiotherapy (3DCRT). The IC with buildup cap was mounted on linear accelerator EPID frame with fixed source to chamber distance of 146.3 cm, using a locally fabricated mount. S t s were obtained for different water phantom thicknesses and radiation field sizes which were then used to generate a calibration table against calculated midplane doses at isocenter (D iso,TPS ), derived from the treatment planning system. A code was developed using MATLAB software which was used to estimate the in vivo dose at isocenter (D iso,Transit ) from the measured S t s. A locally fabricated pelvic phantom validated the estimations of D iso,Transit before implementing this method on actual patients. On-line dose estimations were made (3 times during treatment for each patient) in 24 patients. The D iso,Transit agreement with D iso,TPS in phantom was within 1.7% and the mean percentage deviation with standard deviation is −1.37% ±2.03% (n = 72) observed in patients. Estimated in vivo dose at isocenter with this method provides a good agreement with planned ones which can be implemented as part of quality assurance in pelvic sites treated with simple techniques, for example, 3DCRT where there is a need for documentation of planned dose delivery.http://www.jmp.org.in/article.asp?issn=0971-6203;year=2016;volume=41;issue=4;spage=224;epage=233;aulast=PuthaCervix cancer; clinical dosimetry; conformal radiotherapy; on-line dose verification
collection DOAJ
language English
format Article
sources DOAJ
author Suman Kumar Putha
P U Saxena
S Banerjee
Challapalli Srinivas
B M Vadhiraja
Ramamoorthy Ravichandran
Mary Joan
K Dinesh Pai
spellingShingle Suman Kumar Putha
P U Saxena
S Banerjee
Challapalli Srinivas
B M Vadhiraja
Ramamoorthy Ravichandran
Mary Joan
K Dinesh Pai
On-line estimations of delivered radiation doses in three-dimensional conformal radiotherapy treatments of carcinoma uterine cervix patients in linear accelerator
Journal of Medical Physics
Cervix cancer; clinical dosimetry; conformal radiotherapy; on-line dose verification
author_facet Suman Kumar Putha
P U Saxena
S Banerjee
Challapalli Srinivas
B M Vadhiraja
Ramamoorthy Ravichandran
Mary Joan
K Dinesh Pai
author_sort Suman Kumar Putha
title On-line estimations of delivered radiation doses in three-dimensional conformal radiotherapy treatments of carcinoma uterine cervix patients in linear accelerator
title_short On-line estimations of delivered radiation doses in three-dimensional conformal radiotherapy treatments of carcinoma uterine cervix patients in linear accelerator
title_full On-line estimations of delivered radiation doses in three-dimensional conformal radiotherapy treatments of carcinoma uterine cervix patients in linear accelerator
title_fullStr On-line estimations of delivered radiation doses in three-dimensional conformal radiotherapy treatments of carcinoma uterine cervix patients in linear accelerator
title_full_unstemmed On-line estimations of delivered radiation doses in three-dimensional conformal radiotherapy treatments of carcinoma uterine cervix patients in linear accelerator
title_sort on-line estimations of delivered radiation doses in three-dimensional conformal radiotherapy treatments of carcinoma uterine cervix patients in linear accelerator
publisher Wolters Kluwer Medknow Publications
series Journal of Medical Physics
issn 0971-6203
1998-3913
publishDate 2016-01-01
description Transmission of radiation fluence through patient′s body has a correlation to the planned target dose. A method to estimate the delivered dose to target volumes was standardized using a beam level 0.6 cc ionization chamber (IC) positioned at electronic portal imaging device (EPID) plane from the measured transit signal (S t ) in patients with cancer of uterine cervix treated with three-dimensional conformal radiotherapy (3DCRT). The IC with buildup cap was mounted on linear accelerator EPID frame with fixed source to chamber distance of 146.3 cm, using a locally fabricated mount. S t s were obtained for different water phantom thicknesses and radiation field sizes which were then used to generate a calibration table against calculated midplane doses at isocenter (D iso,TPS ), derived from the treatment planning system. A code was developed using MATLAB software which was used to estimate the in vivo dose at isocenter (D iso,Transit ) from the measured S t s. A locally fabricated pelvic phantom validated the estimations of D iso,Transit before implementing this method on actual patients. On-line dose estimations were made (3 times during treatment for each patient) in 24 patients. The D iso,Transit agreement with D iso,TPS in phantom was within 1.7% and the mean percentage deviation with standard deviation is −1.37% ±2.03% (n = 72) observed in patients. Estimated in vivo dose at isocenter with this method provides a good agreement with planned ones which can be implemented as part of quality assurance in pelvic sites treated with simple techniques, for example, 3DCRT where there is a need for documentation of planned dose delivery.
topic Cervix cancer; clinical dosimetry; conformal radiotherapy; on-line dose verification
url http://www.jmp.org.in/article.asp?issn=0971-6203;year=2016;volume=41;issue=4;spage=224;epage=233;aulast=Putha
work_keys_str_mv AT sumankumarputha onlineestimationsofdeliveredradiationdosesinthreedimensionalconformalradiotherapytreatmentsofcarcinomauterinecervixpatientsinlinearaccelerator
AT pusaxena onlineestimationsofdeliveredradiationdosesinthreedimensionalconformalradiotherapytreatmentsofcarcinomauterinecervixpatientsinlinearaccelerator
AT sbanerjee onlineestimationsofdeliveredradiationdosesinthreedimensionalconformalradiotherapytreatmentsofcarcinomauterinecervixpatientsinlinearaccelerator
AT challapallisrinivas onlineestimationsofdeliveredradiationdosesinthreedimensionalconformalradiotherapytreatmentsofcarcinomauterinecervixpatientsinlinearaccelerator
AT bmvadhiraja onlineestimationsofdeliveredradiationdosesinthreedimensionalconformalradiotherapytreatmentsofcarcinomauterinecervixpatientsinlinearaccelerator
AT ramamoorthyravichandran onlineestimationsofdeliveredradiationdosesinthreedimensionalconformalradiotherapytreatmentsofcarcinomauterinecervixpatientsinlinearaccelerator
AT maryjoan onlineestimationsofdeliveredradiationdosesinthreedimensionalconformalradiotherapytreatmentsofcarcinomauterinecervixpatientsinlinearaccelerator
AT kdineshpai onlineestimationsofdeliveredradiationdosesinthreedimensionalconformalradiotherapytreatmentsofcarcinomauterinecervixpatientsinlinearaccelerator
_version_ 1725716133530566656