DESIGN OF THE NEW DEVICE FOR THE MAGNETIC STRUCTURESCOPY USING FEATURES OF THE RESIDUAL MAGNETIZATION HYSTERESIS DURING ARTICLE PULSED REVERSAL MAGNETIZING

The hysteresis effect of the normal component of the residual magnetization field strength during local pulsed reversal magnetizing of ferromagnetic articles and using its features for quality testing of mediumcarbon steel articles hardening and tempering, articles surface-hardened layer thickness a...

Full description

Bibliographic Details
Main Authors: V. F. Matyuk, M. A. Melgui
Format: Article
Language:English
Published: Belarusian National Technical University 2015-04-01
Series:Pribory i Metody Izmerenij
Online Access:https://pimi.bntu.by/jour/article/view/159
Description
Summary:The hysteresis effect of the normal component of the residual magnetization field strength during local pulsed reversal magnetizing of ferromagnetic articles and using its features for quality testing of mediumcarbon steel articles hardening and tempering, articles surface-hardened layer thickness and hardness after induction hardening are presented. Design principles, structure, purposes and technical characteristics of the pulsed magnetic multiparameter analyzer IMA-M for set forth above problems of the non-destructive testing are given.
ISSN:2220-9506