Studying Maximum Plantar Stress per Insole Design Using Foot CT-Scan Images of Hyperelastic Soft Tissues

The insole shape and the resulting plantar stress distribution have a pivotal impact on overall health. In this paper, by Finite Element Method, maximum stress value and stress distribution of plantar were studied for different insoles designs, which are the flat surface and the custom-molded (confo...

Full description

Bibliographic Details
Main Authors: Ali Sarikhani, Abbas Motalebizadeh, Sasan Asiaei, Babak Kamali Doost Azad
Format: Article
Language:English
Published: Hindawi Limited 2016-01-01
Series:Applied Bionics and Biomechanics
Online Access:http://dx.doi.org/10.1155/2016/8985690
id doaj-65daabb4fbf04eb698b922c6521b935a
record_format Article
spelling doaj-65daabb4fbf04eb698b922c6521b935a2021-07-02T09:19:30ZengHindawi LimitedApplied Bionics and Biomechanics1176-23221754-21032016-01-01201610.1155/2016/89856908985690Studying Maximum Plantar Stress per Insole Design Using Foot CT-Scan Images of Hyperelastic Soft TissuesAli Sarikhani0Abbas Motalebizadeh1Sasan Asiaei2Babak Kamali Doost Azad3School of Mechanical Engineering, Iran University of Science and Technology, Tehran 1684613114, IranSchool of Mechanical Engineering, Iran University of Science and Technology, Tehran 1684613114, IranSensors and Integrated Biomicrofluidics, Mems Laboratory, School of Mechanical Engineering, Iran University of Science and Technology, Tehran 1684613114, IranSchool of Mechanical Engineering, Iran University of Science and Technology, Tehran 1684613114, IranThe insole shape and the resulting plantar stress distribution have a pivotal impact on overall health. In this paper, by Finite Element Method, maximum stress value and stress distribution of plantar were studied for different insoles designs, which are the flat surface and the custom-molded (conformal) surface. Moreover, insole thickness, heel’s height, and different materials were used to minimize the maximum stress and achieve the most uniform stress distribution. The foot shape and its details used in this paper were imported from online CT-Scan images. Results show that the custom-molded insole reduced maximum stress 40% more than the flat surface insole. Upon increase of thickness in both insole types, stress distribution becomes more uniform and maximum stress value decreases up to 10%; however, increase of thickness becomes ineffective above a threshold of 1 cm. By increasing heel height (degree of insole), maximum stress moves from heel to toes and becomes more uniform. Therefore, this scenario is very helpful for control of stress in 0.2° to 0.4° degrees for custom-molded insole and over 1° for flat insole. By changing the material of the insole, the value of maximum stress remains nearly constant. The custom-molded (conformal) insole which has 0.5 to 1 cm thickness and 0.2° to 0.4° degrees is found to be the most compatible form for foot.http://dx.doi.org/10.1155/2016/8985690
collection DOAJ
language English
format Article
sources DOAJ
author Ali Sarikhani
Abbas Motalebizadeh
Sasan Asiaei
Babak Kamali Doost Azad
spellingShingle Ali Sarikhani
Abbas Motalebizadeh
Sasan Asiaei
Babak Kamali Doost Azad
Studying Maximum Plantar Stress per Insole Design Using Foot CT-Scan Images of Hyperelastic Soft Tissues
Applied Bionics and Biomechanics
author_facet Ali Sarikhani
Abbas Motalebizadeh
Sasan Asiaei
Babak Kamali Doost Azad
author_sort Ali Sarikhani
title Studying Maximum Plantar Stress per Insole Design Using Foot CT-Scan Images of Hyperelastic Soft Tissues
title_short Studying Maximum Plantar Stress per Insole Design Using Foot CT-Scan Images of Hyperelastic Soft Tissues
title_full Studying Maximum Plantar Stress per Insole Design Using Foot CT-Scan Images of Hyperelastic Soft Tissues
title_fullStr Studying Maximum Plantar Stress per Insole Design Using Foot CT-Scan Images of Hyperelastic Soft Tissues
title_full_unstemmed Studying Maximum Plantar Stress per Insole Design Using Foot CT-Scan Images of Hyperelastic Soft Tissues
title_sort studying maximum plantar stress per insole design using foot ct-scan images of hyperelastic soft tissues
publisher Hindawi Limited
series Applied Bionics and Biomechanics
issn 1176-2322
1754-2103
publishDate 2016-01-01
description The insole shape and the resulting plantar stress distribution have a pivotal impact on overall health. In this paper, by Finite Element Method, maximum stress value and stress distribution of plantar were studied for different insoles designs, which are the flat surface and the custom-molded (conformal) surface. Moreover, insole thickness, heel’s height, and different materials were used to minimize the maximum stress and achieve the most uniform stress distribution. The foot shape and its details used in this paper were imported from online CT-Scan images. Results show that the custom-molded insole reduced maximum stress 40% more than the flat surface insole. Upon increase of thickness in both insole types, stress distribution becomes more uniform and maximum stress value decreases up to 10%; however, increase of thickness becomes ineffective above a threshold of 1 cm. By increasing heel height (degree of insole), maximum stress moves from heel to toes and becomes more uniform. Therefore, this scenario is very helpful for control of stress in 0.2° to 0.4° degrees for custom-molded insole and over 1° for flat insole. By changing the material of the insole, the value of maximum stress remains nearly constant. The custom-molded (conformal) insole which has 0.5 to 1 cm thickness and 0.2° to 0.4° degrees is found to be the most compatible form for foot.
url http://dx.doi.org/10.1155/2016/8985690
work_keys_str_mv AT alisarikhani studyingmaximumplantarstressperinsoledesignusingfootctscanimagesofhyperelasticsofttissues
AT abbasmotalebizadeh studyingmaximumplantarstressperinsoledesignusingfootctscanimagesofhyperelasticsofttissues
AT sasanasiaei studyingmaximumplantarstressperinsoledesignusingfootctscanimagesofhyperelasticsofttissues
AT babakkamalidoostazad studyingmaximumplantarstressperinsoledesignusingfootctscanimagesofhyperelasticsofttissues
_version_ 1721333266315739136