An algorithm for doble difference joint hypocenter determination: application to the 2002 Molise (Central Italy) earthquake sequence
We have developed an original computer code for double difference hypocenter determination including an independent routine for the cross-correlation estimate of the time difference between two waveform segments, relative to different events recorded by the same stations. This computer code has been...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Istituto Nazionale di Geofisica e Vulcanologia (INGV)
2006-06-01
|
Series: | Annals of Geophysics |
Subjects: | |
Online Access: | http://www.annalsofgeophysics.eu/index.php/annals/article/view/3134 |
id |
doaj-65a599e2b3c545149473f9c9e3daa50c |
---|---|
record_format |
Article |
spelling |
doaj-65a599e2b3c545149473f9c9e3daa50c2020-11-24T22:51:47ZengIstituto Nazionale di Geofisica e Vulcanologia (INGV)Annals of Geophysics1593-52132037-416X2006-06-01492-310.4401/ag-3134An algorithm for doble difference joint hypocenter determination: application to the 2002 Molise (Central Italy) earthquake sequenceA. GiuntiniR. ConsoleWe have developed an original computer code for double difference hypocenter determination including an independent routine for the cross-correlation estimate of the time difference between two waveform segments, relative to different events recorded by the same stations. This computer code has been tested relocating a set of 26 events recorded by the seismic stations of the telemetered Italian national network operated by the INGV. The hypocentral solutions so obtained are characterized by standard deviations typically of the order of magnitude of 50 m, in comparison with the errors of a few kilometers characterizing the performance of the INGV bulletins. The proximity of hypocenters in several groups of events closely separated in time shows that our relocations are the result of an accurate analysis, rather than that of random errors. The method developed in this study is suitable for rapid and accurate hypocentral determination carried out by a permanent sparsely distributed network of stations, even before that mobile equipment installed in the area affected by new seismic activity allows higher resolution locations.http://www.annalsofgeophysics.eu/index.php/annals/article/view/3134AftershocksForeshocksJoint Hypocenter DeterminationDouble Difference |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
A. Giuntini R. Console |
spellingShingle |
A. Giuntini R. Console An algorithm for doble difference joint hypocenter determination: application to the 2002 Molise (Central Italy) earthquake sequence Annals of Geophysics Aftershocks Foreshocks Joint Hypocenter Determination Double Difference |
author_facet |
A. Giuntini R. Console |
author_sort |
A. Giuntini |
title |
An algorithm for doble difference joint hypocenter determination: application to the 2002 Molise (Central Italy) earthquake sequence |
title_short |
An algorithm for doble difference joint hypocenter determination: application to the 2002 Molise (Central Italy) earthquake sequence |
title_full |
An algorithm for doble difference joint hypocenter determination: application to the 2002 Molise (Central Italy) earthquake sequence |
title_fullStr |
An algorithm for doble difference joint hypocenter determination: application to the 2002 Molise (Central Italy) earthquake sequence |
title_full_unstemmed |
An algorithm for doble difference joint hypocenter determination: application to the 2002 Molise (Central Italy) earthquake sequence |
title_sort |
algorithm for doble difference joint hypocenter determination: application to the 2002 molise (central italy) earthquake sequence |
publisher |
Istituto Nazionale di Geofisica e Vulcanologia (INGV) |
series |
Annals of Geophysics |
issn |
1593-5213 2037-416X |
publishDate |
2006-06-01 |
description |
We have developed an original computer code for double difference hypocenter determination including an independent routine for the cross-correlation estimate of the time difference between two waveform segments, relative to different events recorded by the same stations. This computer code has been tested relocating a set of 26 events recorded by the seismic stations of the telemetered Italian national network operated by the INGV. The hypocentral solutions so obtained are characterized by standard deviations typically of the order of magnitude of 50 m, in comparison with the errors of a few kilometers characterizing the performance of the INGV bulletins. The proximity of hypocenters in several groups of events closely separated in time shows that our relocations are the result of an accurate analysis, rather than that of random errors. The method developed in this study is suitable for rapid and accurate hypocentral determination carried out by a permanent sparsely distributed network of stations, even before that mobile equipment installed in the area affected by new seismic activity allows higher resolution locations. |
topic |
Aftershocks Foreshocks Joint Hypocenter Determination Double Difference |
url |
http://www.annalsofgeophysics.eu/index.php/annals/article/view/3134 |
work_keys_str_mv |
AT agiuntini analgorithmfordobledifferencejointhypocenterdeterminationapplicationtothe2002molisecentralitalyearthquakesequence AT rconsole analgorithmfordobledifferencejointhypocenterdeterminationapplicationtothe2002molisecentralitalyearthquakesequence AT agiuntini algorithmfordobledifferencejointhypocenterdeterminationapplicationtothe2002molisecentralitalyearthquakesequence AT rconsole algorithmfordobledifferencejointhypocenterdeterminationapplicationtothe2002molisecentralitalyearthquakesequence |
_version_ |
1725668703251464192 |