An algorithm for doble difference joint hypocenter determination: application to the 2002 Molise (Central Italy) earthquake sequence

We have developed an original computer code for double difference hypocenter determination including an independent routine for the cross-correlation estimate of the time difference between two waveform segments, relative to different events recorded by the same stations. This computer code has been...

Full description

Bibliographic Details
Main Authors: A. Giuntini, R. Console
Format: Article
Language:English
Published: Istituto Nazionale di Geofisica e Vulcanologia (INGV) 2006-06-01
Series:Annals of Geophysics
Subjects:
Online Access:http://www.annalsofgeophysics.eu/index.php/annals/article/view/3134
id doaj-65a599e2b3c545149473f9c9e3daa50c
record_format Article
spelling doaj-65a599e2b3c545149473f9c9e3daa50c2020-11-24T22:51:47ZengIstituto Nazionale di Geofisica e Vulcanologia (INGV)Annals of Geophysics1593-52132037-416X2006-06-01492-310.4401/ag-3134An algorithm for doble difference joint hypocenter determination: application to the 2002 Molise (Central Italy) earthquake sequenceA. GiuntiniR. ConsoleWe have developed an original computer code for double difference hypocenter determination including an independent routine for the cross-correlation estimate of the time difference between two waveform segments, relative to different events recorded by the same stations. This computer code has been tested relocating a set of 26 events recorded by the seismic stations of the telemetered Italian national network operated by the INGV. The hypocentral solutions so obtained are characterized by standard deviations typically of the order of magnitude of 50 m, in comparison with the errors of a few kilometers characterizing the performance of the INGV bulletins. The proximity of hypocenters in several groups of events closely separated in time shows that our relocations are the result of an accurate analysis, rather than that of random errors. The method developed in this study is suitable for rapid and accurate hypocentral determination carried out by a permanent sparsely distributed network of stations, even before that mobile equipment installed in the area affected by new seismic activity allows higher resolution locations.http://www.annalsofgeophysics.eu/index.php/annals/article/view/3134AftershocksForeshocksJoint Hypocenter DeterminationDouble Difference
collection DOAJ
language English
format Article
sources DOAJ
author A. Giuntini
R. Console
spellingShingle A. Giuntini
R. Console
An algorithm for doble difference joint hypocenter determination: application to the 2002 Molise (Central Italy) earthquake sequence
Annals of Geophysics
Aftershocks
Foreshocks
Joint Hypocenter Determination
Double Difference
author_facet A. Giuntini
R. Console
author_sort A. Giuntini
title An algorithm for doble difference joint hypocenter determination: application to the 2002 Molise (Central Italy) earthquake sequence
title_short An algorithm for doble difference joint hypocenter determination: application to the 2002 Molise (Central Italy) earthquake sequence
title_full An algorithm for doble difference joint hypocenter determination: application to the 2002 Molise (Central Italy) earthquake sequence
title_fullStr An algorithm for doble difference joint hypocenter determination: application to the 2002 Molise (Central Italy) earthquake sequence
title_full_unstemmed An algorithm for doble difference joint hypocenter determination: application to the 2002 Molise (Central Italy) earthquake sequence
title_sort algorithm for doble difference joint hypocenter determination: application to the 2002 molise (central italy) earthquake sequence
publisher Istituto Nazionale di Geofisica e Vulcanologia (INGV)
series Annals of Geophysics
issn 1593-5213
2037-416X
publishDate 2006-06-01
description We have developed an original computer code for double difference hypocenter determination including an independent routine for the cross-correlation estimate of the time difference between two waveform segments, relative to different events recorded by the same stations. This computer code has been tested relocating a set of 26 events recorded by the seismic stations of the telemetered Italian national network operated by the INGV. The hypocentral solutions so obtained are characterized by standard deviations typically of the order of magnitude of 50 m, in comparison with the errors of a few kilometers characterizing the performance of the INGV bulletins. The proximity of hypocenters in several groups of events closely separated in time shows that our relocations are the result of an accurate analysis, rather than that of random errors. The method developed in this study is suitable for rapid and accurate hypocentral determination carried out by a permanent sparsely distributed network of stations, even before that mobile equipment installed in the area affected by new seismic activity allows higher resolution locations.
topic Aftershocks
Foreshocks
Joint Hypocenter Determination
Double Difference
url http://www.annalsofgeophysics.eu/index.php/annals/article/view/3134
work_keys_str_mv AT agiuntini analgorithmfordobledifferencejointhypocenterdeterminationapplicationtothe2002molisecentralitalyearthquakesequence
AT rconsole analgorithmfordobledifferencejointhypocenterdeterminationapplicationtothe2002molisecentralitalyearthquakesequence
AT agiuntini algorithmfordobledifferencejointhypocenterdeterminationapplicationtothe2002molisecentralitalyearthquakesequence
AT rconsole algorithmfordobledifferencejointhypocenterdeterminationapplicationtothe2002molisecentralitalyearthquakesequence
_version_ 1725668703251464192