Hypofractionated radiotherapy for lung tumors with online cone beam CT guidance and active breathing control
<p>Abstract</p> <p>Background</p> <p>To study the set-up errors, PTV margin and toxicity of cone beam CT (CBCT) guided hypofractionated radiotherapy with active breathing control (ABC) for patients with non-small cell lung cancer (NSCLC) or metastatic tumors in lung.<...
Main Authors: | , , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
BMC
2010-02-01
|
Series: | Radiation Oncology |
Online Access: | http://www.ro-journal.com/content/5/1/19 |
id |
doaj-657d086d57664bbea405508999f9b275 |
---|---|
record_format |
Article |
spelling |
doaj-657d086d57664bbea405508999f9b2752020-11-24T20:47:26ZengBMCRadiation Oncology1748-717X2010-02-01511910.1186/1748-717X-5-19Hypofractionated radiotherapy for lung tumors with online cone beam CT guidance and active breathing controlWang XinXu QinfengJiang XiaoqingZhong RenmingWang JinZhang HongShen YaliBai SenXu Feng<p>Abstract</p> <p>Background</p> <p>To study the set-up errors, PTV margin and toxicity of cone beam CT (CBCT) guided hypofractionated radiotherapy with active breathing control (ABC) for patients with non-small cell lung cancer (NSCLC) or metastatic tumors in lung.</p> <p>Methods</p> <p>32 tumors in 20 patients were treated. Based on the location of tumor, dose per fraction given to tumor was divided into three groups: 12 Gy, 8 Gy and 6 Gy. ABC is applied for every patient. During each treatment, patients receive CBCT scan for online set-up correction. The pre- and post-correction setup errors between fractions, the interfractional and intrafractional, set-up errors, PTV margin as well as toxicity are analyzed.</p> <p>Results</p> <p>The pre-correction systematic and random errors in the left-right (LR), superior-inferior (SI), anterior-posterior (AP) directions were 3.7 mm and 5.3 mm, 3.1 mm and 2.1 mm, 3.7 mm and 2.8 mm, respectively, while the post-correction residual errors were 0.6 mm and 0.8 mm, 0.8 mm and 0.8 mm, 1.2 mm and 1.3 mm, respectively. There was an obvious intrafractional shift of tumor position. The pre-correction PTV margin was 9.5 mm in LR, 14.1 mm in SI and 8.2 mm in AP direction. After CBCT guided online correction, the PTV margin was markedly reduced in all three directions. The post-correction margins ranged 1.5 to 2.1 mm. The treatment was well tolerated by patients, of whom there were 4 (20%) grade1-2 acute pneumonitis, 3 (15%) grade1 acute esophagitis, 2 (10%) grade1 late pneumonitis and 1 (5%) grade 1 late esophagitis.</p> <p>Conclusion</p> <p>The positioning errors for lung SBRT using ABC were significant. Online correction with CBCT image guidance should be applied to reduce setup errors and PTV margin, which may reduce radiotherapy toxicity of tissues when ABC was used.</p> http://www.ro-journal.com/content/5/1/19 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Wang Xin Xu Qinfeng Jiang Xiaoqing Zhong Renming Wang Jin Zhang Hong Shen Yali Bai Sen Xu Feng |
spellingShingle |
Wang Xin Xu Qinfeng Jiang Xiaoqing Zhong Renming Wang Jin Zhang Hong Shen Yali Bai Sen Xu Feng Hypofractionated radiotherapy for lung tumors with online cone beam CT guidance and active breathing control Radiation Oncology |
author_facet |
Wang Xin Xu Qinfeng Jiang Xiaoqing Zhong Renming Wang Jin Zhang Hong Shen Yali Bai Sen Xu Feng |
author_sort |
Wang Xin |
title |
Hypofractionated radiotherapy for lung tumors with online cone beam CT guidance and active breathing control |
title_short |
Hypofractionated radiotherapy for lung tumors with online cone beam CT guidance and active breathing control |
title_full |
Hypofractionated radiotherapy for lung tumors with online cone beam CT guidance and active breathing control |
title_fullStr |
Hypofractionated radiotherapy for lung tumors with online cone beam CT guidance and active breathing control |
title_full_unstemmed |
Hypofractionated radiotherapy for lung tumors with online cone beam CT guidance and active breathing control |
title_sort |
hypofractionated radiotherapy for lung tumors with online cone beam ct guidance and active breathing control |
publisher |
BMC |
series |
Radiation Oncology |
issn |
1748-717X |
publishDate |
2010-02-01 |
description |
<p>Abstract</p> <p>Background</p> <p>To study the set-up errors, PTV margin and toxicity of cone beam CT (CBCT) guided hypofractionated radiotherapy with active breathing control (ABC) for patients with non-small cell lung cancer (NSCLC) or metastatic tumors in lung.</p> <p>Methods</p> <p>32 tumors in 20 patients were treated. Based on the location of tumor, dose per fraction given to tumor was divided into three groups: 12 Gy, 8 Gy and 6 Gy. ABC is applied for every patient. During each treatment, patients receive CBCT scan for online set-up correction. The pre- and post-correction setup errors between fractions, the interfractional and intrafractional, set-up errors, PTV margin as well as toxicity are analyzed.</p> <p>Results</p> <p>The pre-correction systematic and random errors in the left-right (LR), superior-inferior (SI), anterior-posterior (AP) directions were 3.7 mm and 5.3 mm, 3.1 mm and 2.1 mm, 3.7 mm and 2.8 mm, respectively, while the post-correction residual errors were 0.6 mm and 0.8 mm, 0.8 mm and 0.8 mm, 1.2 mm and 1.3 mm, respectively. There was an obvious intrafractional shift of tumor position. The pre-correction PTV margin was 9.5 mm in LR, 14.1 mm in SI and 8.2 mm in AP direction. After CBCT guided online correction, the PTV margin was markedly reduced in all three directions. The post-correction margins ranged 1.5 to 2.1 mm. The treatment was well tolerated by patients, of whom there were 4 (20%) grade1-2 acute pneumonitis, 3 (15%) grade1 acute esophagitis, 2 (10%) grade1 late pneumonitis and 1 (5%) grade 1 late esophagitis.</p> <p>Conclusion</p> <p>The positioning errors for lung SBRT using ABC were significant. Online correction with CBCT image guidance should be applied to reduce setup errors and PTV margin, which may reduce radiotherapy toxicity of tissues when ABC was used.</p> |
url |
http://www.ro-journal.com/content/5/1/19 |
work_keys_str_mv |
AT wangxin hypofractionatedradiotherapyforlungtumorswithonlineconebeamctguidanceandactivebreathingcontrol AT xuqinfeng hypofractionatedradiotherapyforlungtumorswithonlineconebeamctguidanceandactivebreathingcontrol AT jiangxiaoqing hypofractionatedradiotherapyforlungtumorswithonlineconebeamctguidanceandactivebreathingcontrol AT zhongrenming hypofractionatedradiotherapyforlungtumorswithonlineconebeamctguidanceandactivebreathingcontrol AT wangjin hypofractionatedradiotherapyforlungtumorswithonlineconebeamctguidanceandactivebreathingcontrol AT zhanghong hypofractionatedradiotherapyforlungtumorswithonlineconebeamctguidanceandactivebreathingcontrol AT shenyali hypofractionatedradiotherapyforlungtumorswithonlineconebeamctguidanceandactivebreathingcontrol AT baisen hypofractionatedradiotherapyforlungtumorswithonlineconebeamctguidanceandactivebreathingcontrol AT xufeng hypofractionatedradiotherapyforlungtumorswithonlineconebeamctguidanceandactivebreathingcontrol |
_version_ |
1716810069488697344 |