Evaluation of two closed-system drug transfer device in the antineoplastic drug elaboration process

Objective: to assess the impact of two closed-system drug transfer device on the local and environmental contamination and preparation times in the process of preparation of parenteral chemotherapy compared to the standard system. Method: prospective observational study. Two different closed- system...

Full description

Bibliographic Details
Main Authors: Sandra Gómez-Álvarez, Begoña Porta-Oltra, Marta Hernandez-Griso, Francisca Pérez-Labaña, Mónica Climente-Martí
Format: Article
Language:English
Published: Grupo Aula Médica 2016-01-01
Series:Farmacia Hospitalaria
Subjects:
Online Access:http://www.aulamedica.es/fh/pdf/9059.pdf
id doaj-64eb34940e004766ac3ad522506f893b
record_format Article
spelling doaj-64eb34940e004766ac3ad522506f893b2020-11-24T23:09:10ZengGrupo Aula MédicaFarmacia Hospitalaria1130-63432171-86952016-01-01401364310.7399/fh.2016.40.1.9059Evaluation of two closed-system drug transfer device in the antineoplastic drug elaboration processSandra Gómez-Álvarez0Begoña Porta-Oltra1Marta Hernandez-Griso2Francisca Pérez-Labaña3Mónica Climente-Martí4Sevicio de Farmacia Hospital Universitario Doctor Peset, Valencia. EspañaSevicio de Farmacia Hospital Universitario Doctor Peset, Valencia. EspañaSevicio de Farmacia Hospital Universitario Doctor Peset, Valencia. España.Sevicio de Farmacia Hospital Universitario Doctor Peset, Valencia. EspañaSevicio de Farmacia Hospital Universitario Doctor Peset, Valencia. EspañaObjective: to assess the impact of two closed-system drug transfer device on the local and environmental contamination and preparation times in the process of preparation of parenteral chemotherapy compared to the standard system. Method: prospective observational study. Two different closed- systems providers, Care Fusion® and Icu Medical®, were compared to standard preparation. 15 nurses of Pharmacy Department prepared 5 preparations each one, one with the standard procedure and four using closed-systems. To evaluate the contamination, a fluorescein solution 0.5% was prepared. Two kind of contamination were evaluated, local (three points connection: closed-system connect vial, syringe and final infusion bags) and environmental (gloves and countertop). Percentage of contaminated preparations was obtained in each one. Time taken by each nurse in each preparation was recorded. Results: 75 preparations were prepared. Local contamination was reduced 21% and 75% in closed-system Icu Medical® and Care Fusion® respectively. Care Fusion® closed system, local contamination was significantly lower than the standard system to the vial, syringe and final package, while Icu Medical® closed-systems only was significantly lower in the connection to the vial. Time of preparation was increased significantly with the use of closed-system between 23.4 and 30.5 seconds. Conclusions: both closed-systems drug transfer device have shown an improvement in contamination than the use of the standard system. However, preparation time has been significantly increased with the use of both systemshttp://www.aulamedica.es/fh/pdf/9059.pdfCytotastic drugOccupational exposure; Closed system drug transfer device
collection DOAJ
language English
format Article
sources DOAJ
author Sandra Gómez-Álvarez
Begoña Porta-Oltra
Marta Hernandez-Griso
Francisca Pérez-Labaña
Mónica Climente-Martí
spellingShingle Sandra Gómez-Álvarez
Begoña Porta-Oltra
Marta Hernandez-Griso
Francisca Pérez-Labaña
Mónica Climente-Martí
Evaluation of two closed-system drug transfer device in the antineoplastic drug elaboration process
Farmacia Hospitalaria
Cytotastic drug
Occupational exposure
; Closed system drug transfer device
author_facet Sandra Gómez-Álvarez
Begoña Porta-Oltra
Marta Hernandez-Griso
Francisca Pérez-Labaña
Mónica Climente-Martí
author_sort Sandra Gómez-Álvarez
title Evaluation of two closed-system drug transfer device in the antineoplastic drug elaboration process
title_short Evaluation of two closed-system drug transfer device in the antineoplastic drug elaboration process
title_full Evaluation of two closed-system drug transfer device in the antineoplastic drug elaboration process
title_fullStr Evaluation of two closed-system drug transfer device in the antineoplastic drug elaboration process
title_full_unstemmed Evaluation of two closed-system drug transfer device in the antineoplastic drug elaboration process
title_sort evaluation of two closed-system drug transfer device in the antineoplastic drug elaboration process
publisher Grupo Aula Médica
series Farmacia Hospitalaria
issn 1130-6343
2171-8695
publishDate 2016-01-01
description Objective: to assess the impact of two closed-system drug transfer device on the local and environmental contamination and preparation times in the process of preparation of parenteral chemotherapy compared to the standard system. Method: prospective observational study. Two different closed- systems providers, Care Fusion® and Icu Medical®, were compared to standard preparation. 15 nurses of Pharmacy Department prepared 5 preparations each one, one with the standard procedure and four using closed-systems. To evaluate the contamination, a fluorescein solution 0.5% was prepared. Two kind of contamination were evaluated, local (three points connection: closed-system connect vial, syringe and final infusion bags) and environmental (gloves and countertop). Percentage of contaminated preparations was obtained in each one. Time taken by each nurse in each preparation was recorded. Results: 75 preparations were prepared. Local contamination was reduced 21% and 75% in closed-system Icu Medical® and Care Fusion® respectively. Care Fusion® closed system, local contamination was significantly lower than the standard system to the vial, syringe and final package, while Icu Medical® closed-systems only was significantly lower in the connection to the vial. Time of preparation was increased significantly with the use of closed-system between 23.4 and 30.5 seconds. Conclusions: both closed-systems drug transfer device have shown an improvement in contamination than the use of the standard system. However, preparation time has been significantly increased with the use of both systems
topic Cytotastic drug
Occupational exposure
; Closed system drug transfer device
url http://www.aulamedica.es/fh/pdf/9059.pdf
work_keys_str_mv AT sandragomezalvarez evaluationoftwoclosedsystemdrugtransferdeviceintheantineoplasticdrugelaborationprocess
AT begonaportaoltra evaluationoftwoclosedsystemdrugtransferdeviceintheantineoplasticdrugelaborationprocess
AT martahernandezgriso evaluationoftwoclosedsystemdrugtransferdeviceintheantineoplasticdrugelaborationprocess
AT franciscaperezlabana evaluationoftwoclosedsystemdrugtransferdeviceintheantineoplasticdrugelaborationprocess
AT monicaclimentemarti evaluationoftwoclosedsystemdrugtransferdeviceintheantineoplasticdrugelaborationprocess
_version_ 1725611164457500672