X-Ray Layered Refocusing Imaging Based on Linear Scanning

In the process of X-ray digital imaging, due to the mutual occlusion of object structures of different depth layers, the image projection information is overlapped. X-CT(Computed-Tomography) and X-CL(Computed-Laminography) are usually used to obtain structural information of objects at different dep...

Full description

Bibliographic Details
Main Authors: Bin Liu, Yue Luo, Ke Li, Xia Zhao
Format: Article
Language:English
Published: IEEE 2020-01-01
Series:IEEE Photonics Journal
Subjects:
Online Access:https://ieeexplore.ieee.org/document/9104904/
id doaj-6409ac6a4d5d46f7a48ce226d04b0acd
record_format Article
spelling doaj-6409ac6a4d5d46f7a48ce226d04b0acd2021-03-29T18:02:05ZengIEEEIEEE Photonics Journal1943-06552020-01-0112311210.1109/JPHOT.2020.29989169104904X-Ray Layered Refocusing Imaging Based on Linear ScanningBin Liu0Yue Luo1https://orcid.org/0000-0002-2691-5511Ke Li2Xia Zhao3School of Information and Communication Engineering, North University of China, Taiyuan, ChinaSchool of Information and Communication Engineering, North University of China, Taiyuan, ChinaSchool of Information and Communication Engineering, North University of China, Taiyuan, ChinaSchool of Information and Communication Engineering, North University of China, Taiyuan, ChinaIn the process of X-ray digital imaging, due to the mutual occlusion of object structures of different depth layers, the image projection information is overlapped. X-CT(Computed-Tomography) and X-CL(Computed-Laminography) are usually used to obtain structural information of objects at different depths, but they are limited by accurate multi-dimensional motion control systems, complex scanning methods and poor real-time computing performance.To solve the problems, this paper proposed a method of X-ray layered imaging based on linear scanning. This method only needs the object to pass through the detection area along a straight line to realize the multi-view imaging, extracts the effective multi-view images information for refocusing imaging, and realizes the reconstruction of different depth layers of the object. Meanwhile, the automatic marking matting algorithm is employed to remove the non-focused interference in the refocused images. Experiments of X-ray layered imaging were conducted, which demonstrated the proposed method can achieve objects reconstruction with different depths, and effectively remove the non-focused interference.https://ieeexplore.ieee.org/document/9104904/X-raylinear scanningrefocusing imagingautomatic marking matting algorithm
collection DOAJ
language English
format Article
sources DOAJ
author Bin Liu
Yue Luo
Ke Li
Xia Zhao
spellingShingle Bin Liu
Yue Luo
Ke Li
Xia Zhao
X-Ray Layered Refocusing Imaging Based on Linear Scanning
IEEE Photonics Journal
X-ray
linear scanning
refocusing imaging
automatic marking matting algorithm
author_facet Bin Liu
Yue Luo
Ke Li
Xia Zhao
author_sort Bin Liu
title X-Ray Layered Refocusing Imaging Based on Linear Scanning
title_short X-Ray Layered Refocusing Imaging Based on Linear Scanning
title_full X-Ray Layered Refocusing Imaging Based on Linear Scanning
title_fullStr X-Ray Layered Refocusing Imaging Based on Linear Scanning
title_full_unstemmed X-Ray Layered Refocusing Imaging Based on Linear Scanning
title_sort x-ray layered refocusing imaging based on linear scanning
publisher IEEE
series IEEE Photonics Journal
issn 1943-0655
publishDate 2020-01-01
description In the process of X-ray digital imaging, due to the mutual occlusion of object structures of different depth layers, the image projection information is overlapped. X-CT(Computed-Tomography) and X-CL(Computed-Laminography) are usually used to obtain structural information of objects at different depths, but they are limited by accurate multi-dimensional motion control systems, complex scanning methods and poor real-time computing performance.To solve the problems, this paper proposed a method of X-ray layered imaging based on linear scanning. This method only needs the object to pass through the detection area along a straight line to realize the multi-view imaging, extracts the effective multi-view images information for refocusing imaging, and realizes the reconstruction of different depth layers of the object. Meanwhile, the automatic marking matting algorithm is employed to remove the non-focused interference in the refocused images. Experiments of X-ray layered imaging were conducted, which demonstrated the proposed method can achieve objects reconstruction with different depths, and effectively remove the non-focused interference.
topic X-ray
linear scanning
refocusing imaging
automatic marking matting algorithm
url https://ieeexplore.ieee.org/document/9104904/
work_keys_str_mv AT binliu xraylayeredrefocusingimagingbasedonlinearscanning
AT yueluo xraylayeredrefocusingimagingbasedonlinearscanning
AT keli xraylayeredrefocusingimagingbasedonlinearscanning
AT xiazhao xraylayeredrefocusingimagingbasedonlinearscanning
_version_ 1724196940507250688