Comparative visual performance with monofocal and multifocal intraocular lenses

Kjell Gunnar Gundersen,1,* Richard Potvin2,*1Privatsykehuset Haugesund, Haugesund, Norway; 2Science in Vision, Burleson, TX, USA *These authors contributed equally to this workBackground: To compare near, intermediate, and distance vision, and quality of vision using appropriate subjective questionn...

Full description

Bibliographic Details
Main Authors: Gundersen KG, Potvin R
Format: Article
Language:English
Published: Dove Medical Press 2013-10-01
Series:Clinical Ophthalmology
Online Access:http://www.dovepress.com/comparative-visual-performance-with-monofocal-and-multifocal-intraocul-a14593
id doaj-63f90d1695e940e5b195259fc62ab2a3
record_format Article
spelling doaj-63f90d1695e940e5b195259fc62ab2a32020-11-24T22:01:11ZengDove Medical PressClinical Ophthalmology1177-54671177-54832013-10-012013default19791985Comparative visual performance with monofocal and multifocal intraocular lensesGundersen KGPotvin RKjell Gunnar Gundersen,1,* Richard Potvin2,*1Privatsykehuset Haugesund, Haugesund, Norway; 2Science in Vision, Burleson, TX, USA *These authors contributed equally to this workBackground: To compare near, intermediate, and distance vision, and quality of vision using appropriate subjective questionnaires, when monofocal or apodized diffractive multifocal intraocular lenses (IOLs) are binocularly implanted.Methods: Patients with different binocular IOLs implanted were recruited after surgery and had their visual acuity tested, and quality of vision evaluated, at a single diagnostic visit between 3 and 8 months after second-eye surgery. Lenses tested included an aspheric monofocal and two apodized diffractive multifocal IOLs with slightly different design parameters. A total of 94 patients were evaluated.Results: Subjects with the ReSTOR® +2.5 D IOL had better near and intermediate vision than those subjects with a monofocal IOL. Intermediate vision was similar to, and near vision slightly lower than, that of subjects with a ReSTOR® +3.0 D IOL implanted. The preferred reading distance was slightly farther out for the +2.5 D relative to the +3.0 D lens, and farthest for the monofocal. Visual acuity at the preferred reading distance was equal with the two multifocal IOLs and significantly worse with the monofocal IOL. Quality of vision measures were highest with the monofocal IOL and similar between the two multifocal IOLs.Conclusion: The data indicate that the ReSTOR +2.5 D IOL provided good intermediate and functional near vision for patients who did not want to accept a higher potential for visual disturbances associated with the ReSTOR +3.0 D IOL, but wanted more near vision than a monofocal IOL generally provides. Quality of vision was not significantly different between the multifocal IOLs, but patient self-selection for each lens type may have been a factor.Keywords: multifocal IOL, near vision, cataract, presbyopiahttp://www.dovepress.com/comparative-visual-performance-with-monofocal-and-multifocal-intraocul-a14593
collection DOAJ
language English
format Article
sources DOAJ
author Gundersen KG
Potvin R
spellingShingle Gundersen KG
Potvin R
Comparative visual performance with monofocal and multifocal intraocular lenses
Clinical Ophthalmology
author_facet Gundersen KG
Potvin R
author_sort Gundersen KG
title Comparative visual performance with monofocal and multifocal intraocular lenses
title_short Comparative visual performance with monofocal and multifocal intraocular lenses
title_full Comparative visual performance with monofocal and multifocal intraocular lenses
title_fullStr Comparative visual performance with monofocal and multifocal intraocular lenses
title_full_unstemmed Comparative visual performance with monofocal and multifocal intraocular lenses
title_sort comparative visual performance with monofocal and multifocal intraocular lenses
publisher Dove Medical Press
series Clinical Ophthalmology
issn 1177-5467
1177-5483
publishDate 2013-10-01
description Kjell Gunnar Gundersen,1,* Richard Potvin2,*1Privatsykehuset Haugesund, Haugesund, Norway; 2Science in Vision, Burleson, TX, USA *These authors contributed equally to this workBackground: To compare near, intermediate, and distance vision, and quality of vision using appropriate subjective questionnaires, when monofocal or apodized diffractive multifocal intraocular lenses (IOLs) are binocularly implanted.Methods: Patients with different binocular IOLs implanted were recruited after surgery and had their visual acuity tested, and quality of vision evaluated, at a single diagnostic visit between 3 and 8 months after second-eye surgery. Lenses tested included an aspheric monofocal and two apodized diffractive multifocal IOLs with slightly different design parameters. A total of 94 patients were evaluated.Results: Subjects with the ReSTOR® +2.5 D IOL had better near and intermediate vision than those subjects with a monofocal IOL. Intermediate vision was similar to, and near vision slightly lower than, that of subjects with a ReSTOR® +3.0 D IOL implanted. The preferred reading distance was slightly farther out for the +2.5 D relative to the +3.0 D lens, and farthest for the monofocal. Visual acuity at the preferred reading distance was equal with the two multifocal IOLs and significantly worse with the monofocal IOL. Quality of vision measures were highest with the monofocal IOL and similar between the two multifocal IOLs.Conclusion: The data indicate that the ReSTOR +2.5 D IOL provided good intermediate and functional near vision for patients who did not want to accept a higher potential for visual disturbances associated with the ReSTOR +3.0 D IOL, but wanted more near vision than a monofocal IOL generally provides. Quality of vision was not significantly different between the multifocal IOLs, but patient self-selection for each lens type may have been a factor.Keywords: multifocal IOL, near vision, cataract, presbyopia
url http://www.dovepress.com/comparative-visual-performance-with-monofocal-and-multifocal-intraocul-a14593
work_keys_str_mv AT gundersenkg comparativevisualperformancewithmonofocalandmultifocalintraocularlenses
AT potvinr comparativevisualperformancewithmonofocalandmultifocalintraocularlenses
_version_ 1725841245902733312