Numerical Simulation Study Of Squeezed Branch Piles Based On Post-grouting Technology

The squeezed branch pile has strong resistance to pressure, pullout and horizontal force, and it also has excellent stability, which makes it widely used in the field of electrical engineering. Based on the ABAQUS, the paper simulates the vertical bearing situation of post-grouting squeezed branch p...

Full description

Bibliographic Details
Main Authors: Ma LiXing, Shi ZhuoPeng, Han Kai, Chang PengFei, He XiaoDong
Format: Article
Language:English
Published: EDP Sciences 2021-01-01
Series:E3S Web of Conferences
Online Access:https://www.e3s-conferences.org/articles/e3sconf/pdf/2021/68/e3sconf_netid21_01038.pdf
Description
Summary:The squeezed branch pile has strong resistance to pressure, pullout and horizontal force, and it also has excellent stability, which makes it widely used in the field of electrical engineering. Based on the ABAQUS, the paper simulates the vertical bearing situation of post-grouting squeezed branch piles, by setting up Set two comparisons of single pile and squeezed branch pile, the bearing capacity, load transfer mechanism and failure mode of post-grouting squeezed branch piles were comprehensively analyzed and compared. Studies have shown that the bearing capacity of the squeezed branch piles with post-grouting technology has increased by 68.1% compared with the traditional squeezed branch piles, and the bearing characteristics of the branches have changed greatly. In this process, the end-bearing function of the branch plate is fully exerted, and the high load-bearing capacity of the grouted strata soil is used to reduce the settlement.
ISSN:2267-1242