Normal Values of Standard Full Field Electroretinography in Healthy Subjects in Northern Iran

Background: Electroretinography (ERG) is known as a diagnostic test for evaluating the performance of different layers of the retina. Its normal values maybe different in different populations. Objectives: Determining the normal values of ERG parameters in patients presenting to an ophthalmologic ce...

Full description

Bibliographic Details
Main Authors: Mansoureh Shokouhian, Yousef Alizadeh, Bahram Khosravi, Ebramim Jafarzadehpour, Hamid Souri
Format: Article
Language:English
Published: Guilan University of Medical Sciences 2017-08-01
Series:Caspian Journal of Neurological Sciences
Subjects:
Online Access:http://cjns.gums.ac.ir/browse.php?a_code=A-10-32-79&slc_lang=en&sid=1
id doaj-6395751a720d40da83bfdd43a323c3f2
record_format Article
spelling doaj-6395751a720d40da83bfdd43a323c3f22020-11-24T21:59:54ZengGuilan University of Medical SciencesCaspian Journal of Neurological Sciences2383-43072423-48182017-08-01310135142Normal Values of Standard Full Field Electroretinography in Healthy Subjects in Northern IranMansoureh Shokouhian0Yousef Alizadeh1Bahram Khosravi2Ebramim Jafarzadehpour3Hamid Souri4 Optometrist, Amiralmomenin Hospital, Rasht, Iran Eye Research Center, Amiralmomenin Hospital, Guilan University of Medical Sciences, Rasht, Iran Assistant Professor of Optometry, Optometry Department, Shahid Beheshti University of Medical Sciences, Tehran, Iran Professor of Optometry, Optometry Department, Iran University of Medical Sciences, Tehran, Iran; jafarzadehpour.e@iums.ac.ir Professor of Epidemiology, Epidemiology Department, Shahid Beheshti University of Medical Sciences, Tehran, Iran Background: Electroretinography (ERG) is known as a diagnostic test for evaluating the performance of different layers of the retina. Its normal values maybe different in different populations. Objectives: Determining the normal values of ERG parameters in patients presenting to an ophthalmologic center in Guilan in northern Iran. Materials and Methods: Fifty-five people presenting to a teaching hospital affiliated to Guilan University of Medical Sciences were studied in autumn and winter 2013.The subjects were diagnosed as healthy in the eye examinations and were examined in terms of the values of amplitude and latency time of ERG waves in accordance with international guidelines for clinical electrophysiology of vision. Results: In this study, 55 patients with a mean age of 35±14 years were studied (40% males with a mean age of 36.00±15.4 years; 60% females, with a mean age of 34.5±14 years). The following results were obtained: amplitude of scotopic 0.01=149±144 µV, scotopic 3=317±157µV, photopic=129±86 µV, 30-Hz flicker=134±38 µV, OS2=25.6±13.9 µV, Latency time scotopic 0.01=53.5±29 sec, Latency Time Scotopic 3=34.3±15.2 sec, N1=13.59±2 sec, P1=18.63±1 sec, N2=21.3±1 sec, P2=26.1±2.7 ms, N3=31.1±4 sec, P3=33.8±4.7 sec, N4=40.9±6.4 sec, P4=44.3±6.4 sec, Latency Time photopic=22.9±7.7 ms, and flicker=54.3±7.5 ms. Men and women were not significantly different in terms of the variables. Left and right eyes, as well as age groups were not significantly different (p=0.05). Conclusion: The results of the current study differed from other studies in terms of the values of amplitude and latency times. Therefore, it is necessary to standardize ERG for each center.http://cjns.gums.ac.ir/browse.php?a_code=A-10-32-79&slc_lang=en&sid=1ElectroretinographyReference Values
collection DOAJ
language English
format Article
sources DOAJ
author Mansoureh Shokouhian
Yousef Alizadeh
Bahram Khosravi
Ebramim Jafarzadehpour
Hamid Souri
spellingShingle Mansoureh Shokouhian
Yousef Alizadeh
Bahram Khosravi
Ebramim Jafarzadehpour
Hamid Souri
Normal Values of Standard Full Field Electroretinography in Healthy Subjects in Northern Iran
Caspian Journal of Neurological Sciences
Electroretinography
Reference Values
author_facet Mansoureh Shokouhian
Yousef Alizadeh
Bahram Khosravi
Ebramim Jafarzadehpour
Hamid Souri
author_sort Mansoureh Shokouhian
title Normal Values of Standard Full Field Electroretinography in Healthy Subjects in Northern Iran
title_short Normal Values of Standard Full Field Electroretinography in Healthy Subjects in Northern Iran
title_full Normal Values of Standard Full Field Electroretinography in Healthy Subjects in Northern Iran
title_fullStr Normal Values of Standard Full Field Electroretinography in Healthy Subjects in Northern Iran
title_full_unstemmed Normal Values of Standard Full Field Electroretinography in Healthy Subjects in Northern Iran
title_sort normal values of standard full field electroretinography in healthy subjects in northern iran
publisher Guilan University of Medical Sciences
series Caspian Journal of Neurological Sciences
issn 2383-4307
2423-4818
publishDate 2017-08-01
description Background: Electroretinography (ERG) is known as a diagnostic test for evaluating the performance of different layers of the retina. Its normal values maybe different in different populations. Objectives: Determining the normal values of ERG parameters in patients presenting to an ophthalmologic center in Guilan in northern Iran. Materials and Methods: Fifty-five people presenting to a teaching hospital affiliated to Guilan University of Medical Sciences were studied in autumn and winter 2013.The subjects were diagnosed as healthy in the eye examinations and were examined in terms of the values of amplitude and latency time of ERG waves in accordance with international guidelines for clinical electrophysiology of vision. Results: In this study, 55 patients with a mean age of 35±14 years were studied (40% males with a mean age of 36.00±15.4 years; 60% females, with a mean age of 34.5±14 years). The following results were obtained: amplitude of scotopic 0.01=149±144 µV, scotopic 3=317±157µV, photopic=129±86 µV, 30-Hz flicker=134±38 µV, OS2=25.6±13.9 µV, Latency time scotopic 0.01=53.5±29 sec, Latency Time Scotopic 3=34.3±15.2 sec, N1=13.59±2 sec, P1=18.63±1 sec, N2=21.3±1 sec, P2=26.1±2.7 ms, N3=31.1±4 sec, P3=33.8±4.7 sec, N4=40.9±6.4 sec, P4=44.3±6.4 sec, Latency Time photopic=22.9±7.7 ms, and flicker=54.3±7.5 ms. Men and women were not significantly different in terms of the variables. Left and right eyes, as well as age groups were not significantly different (p=0.05). Conclusion: The results of the current study differed from other studies in terms of the values of amplitude and latency times. Therefore, it is necessary to standardize ERG for each center.
topic Electroretinography
Reference Values
url http://cjns.gums.ac.ir/browse.php?a_code=A-10-32-79&slc_lang=en&sid=1
work_keys_str_mv AT mansourehshokouhian normalvaluesofstandardfullfieldelectroretinographyinhealthysubjectsinnortherniran
AT yousefalizadeh normalvaluesofstandardfullfieldelectroretinographyinhealthysubjectsinnortherniran
AT bahramkhosravi normalvaluesofstandardfullfieldelectroretinographyinhealthysubjectsinnortherniran
AT ebramimjafarzadehpour normalvaluesofstandardfullfieldelectroretinographyinhealthysubjectsinnortherniran
AT hamidsouri normalvaluesofstandardfullfieldelectroretinographyinhealthysubjectsinnortherniran
_version_ 1725846623838273536