An Inter-Laboratory Comparison for the Urinary Acrolein Biomarker 3-Hydroxypropyl-Mercapturic Acid (3-HPMA)
An inter-laboratory comparison study on the acrolein biomarker of exposure 3-hydroxypropyl-mercapturic acid (3-HPMA) with 12 laboratories from 7 globally distributed countries was performed. The laboratories received coded triplicates of 4 spiked and lyophilized urine samples (LU, 12 samples) as wel...
Main Authors: | , , , , , , , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Sciendo
2017-01-01
|
Series: | Beiträge zur Tabakforschung International |
Subjects: | |
Online Access: | http://www.degruyter.com/view/j/cttr.2017.27.issue-5/cttr-2016-0006/cttr-2016-0006.xml?format=INT |
id |
doaj-637f7edcf6e64cfa98bd902e99b28d26 |
---|---|
record_format |
Article |
spelling |
doaj-637f7edcf6e64cfa98bd902e99b28d262020-11-24T21:50:32ZengSciendoBeiträge zur Tabakforschung International1612-92372017-01-01275657610.1515/cttr-2016-0006cttr-2016-0006An Inter-Laboratory Comparison for the Urinary Acrolein Biomarker 3-Hydroxypropyl-Mercapturic Acid (3-HPMA)Scherer Gerhard0Heller Wolf-Dieter1McEwan Michael2Göen Thomas3Joza Peter4Liu Nan5Newland Kirk6Schettgen Thomas7Wang Sheng8Sohn Hyung-Ok9Troude Valerie10Yuki Dai11Zheng Saijing12Zhou Guojun13 ABF Analytisch-Biologisches Forschungslabor GmbH, Goethestr. 20, 80336 Munich, Germany IFT Institut für Tabakforschung GmbH, Chausseestr. 51A, 10115 Berlin, Germany BAT British American Tobacco, Regents Park Road, Millbrook, Southampton SO15, 8TL, United Kingdom of Great Britain and Northern Ireland Institute and Outpatient Clinic of Occupational, Social and Environmental Medicine, Friedrich-Alexander-Universität Erlangen-Nürnberg, Schillerstr. 25, 91054 Erlangen, Germany Labstat International ULC, 262 Manitou Drive, Kitchener, Ontario, N2C 1L3, Canada CNTQSC China National Tobacco Supervision and Test Centre, No.2 Fengyang Road, Hi-Tech Industry Development Zone Henan, 450001, P.R. China Celerion Inc., 621 Rose St., Lincoln, NE 68502, United States of America Institut für Arbeits- und Sozialmedizin, RWTH Aachen, Pauwelsstr. 30, 52074 Aachen, Germany ZTRI, Zhengzhou Tobacco Research Institute, No.2 Fengyang Street, Hi-Tech Zone, Zhengzhou, 450001, P.R. China KT&G Research Institute, 30 Gajeong-ro, Yuseong-gu, Daejeon, 34128 Korea (Republic of) SEITA-Imperial Tobacco Limited, 48 rue Danton, 45405 Fleury Les Aubrais, France Japan Tobacco Inc., 6-2, Umegaoka, Aoba-ku, Yokohama, Kanagawa 227-8512, Japan Shanghai Tobacco Group Co., Ltd., No. 717 Changyang Road Yangpu District, Shanghai, 200082, P.R. China China Tobacco Zhejiang Industrial Co. Ltd., Technology Center, 77 South Zhongshan Road, Hangzhou 310008, P.R. ChinaAn inter-laboratory comparison study on the acrolein biomarker of exposure 3-hydroxypropyl-mercapturic acid (3-HPMA) with 12 laboratories from 7 globally distributed countries was performed. The laboratories received coded triplicates of 4 spiked and lyophilized urine samples (LU, 12 samples) as well as 5 authentic urine pool samples (PU, 15 samples) covering the 3-HPMA concentration range from background (non-smoking) to heavy smoking levels for analysis by using their own (in-house) analytical method. All laboratories applied liquid chromatography with tandem mass spectrometry (LC-MS/MS), with most of them (10 of 12) using solid phase extraction (SPE) as sample work-up procedure. The intra-laboratory variation (indicating repeatability) was determined by calculating the standard deviation (sr) and the coefficient of variation (CVr) of the triplicates, whereas the inter-laboratory variation (indicating reproducibility) was determined by calculating the standard deviation between laboratories (sR) and the corresponding coefficient of variation (CVR). After removal of outlier samples or laboratories, the mean CVr values for LU and PU test samples ranged from 2.1–3.6% (mean: 2.8%) and 2.4–3.7% (mean: 3.3%), respectively, indicating good repeatability for the determination of 3-HPMA in both sample types. CVR for LU and PU test samples ranged from 9.1–31.9% (mean: 18.8%) and 13.9–27.0% (mean: 18.5%), respectively, indicating limited reproducibility in 3-HPMA analysis for both sample types. Re-calculation of the PU results by applying an embedded calibration (EC), derived from the reported peak areas for the LU test samples, somewhat improved the CVR values (range: 9.6–28.8%, mean: 16.7%).http://www.degruyter.com/view/j/cttr.2017.27.issue-5/cttr-2016-0006/cttr-2016-0006.xml?format=INTInter-laboratory comparison3-hydroxypropyl-mercapturic acid (3-HPMA)intra-laboratory variationinter-laboratory variationrepeatabilityreproducibility |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Scherer Gerhard Heller Wolf-Dieter McEwan Michael Göen Thomas Joza Peter Liu Nan Newland Kirk Schettgen Thomas Wang Sheng Sohn Hyung-Ok Troude Valerie Yuki Dai Zheng Saijing Zhou Guojun |
spellingShingle |
Scherer Gerhard Heller Wolf-Dieter McEwan Michael Göen Thomas Joza Peter Liu Nan Newland Kirk Schettgen Thomas Wang Sheng Sohn Hyung-Ok Troude Valerie Yuki Dai Zheng Saijing Zhou Guojun An Inter-Laboratory Comparison for the Urinary Acrolein Biomarker 3-Hydroxypropyl-Mercapturic Acid (3-HPMA) Beiträge zur Tabakforschung International Inter-laboratory comparison 3-hydroxypropyl-mercapturic acid (3-HPMA) intra-laboratory variation inter-laboratory variation repeatability reproducibility |
author_facet |
Scherer Gerhard Heller Wolf-Dieter McEwan Michael Göen Thomas Joza Peter Liu Nan Newland Kirk Schettgen Thomas Wang Sheng Sohn Hyung-Ok Troude Valerie Yuki Dai Zheng Saijing Zhou Guojun |
author_sort |
Scherer Gerhard |
title |
An Inter-Laboratory Comparison for the Urinary Acrolein Biomarker 3-Hydroxypropyl-Mercapturic Acid (3-HPMA) |
title_short |
An Inter-Laboratory Comparison for the Urinary Acrolein Biomarker 3-Hydroxypropyl-Mercapturic Acid (3-HPMA) |
title_full |
An Inter-Laboratory Comparison for the Urinary Acrolein Biomarker 3-Hydroxypropyl-Mercapturic Acid (3-HPMA) |
title_fullStr |
An Inter-Laboratory Comparison for the Urinary Acrolein Biomarker 3-Hydroxypropyl-Mercapturic Acid (3-HPMA) |
title_full_unstemmed |
An Inter-Laboratory Comparison for the Urinary Acrolein Biomarker 3-Hydroxypropyl-Mercapturic Acid (3-HPMA) |
title_sort |
inter-laboratory comparison for the urinary acrolein biomarker 3-hydroxypropyl-mercapturic acid (3-hpma) |
publisher |
Sciendo |
series |
Beiträge zur Tabakforschung International |
issn |
1612-9237 |
publishDate |
2017-01-01 |
description |
An inter-laboratory comparison study on the acrolein biomarker of exposure 3-hydroxypropyl-mercapturic acid (3-HPMA) with 12 laboratories from 7 globally distributed countries was performed. The laboratories received coded triplicates of 4 spiked and lyophilized urine samples (LU, 12 samples) as well as 5 authentic urine pool samples (PU, 15 samples) covering the 3-HPMA concentration range from background (non-smoking) to heavy smoking levels for analysis by using their own (in-house) analytical method. All laboratories applied liquid chromatography with tandem mass spectrometry (LC-MS/MS), with most of them (10 of 12) using solid phase extraction (SPE) as sample work-up procedure. The intra-laboratory variation (indicating repeatability) was determined by calculating the standard deviation (sr) and the coefficient of variation (CVr) of the triplicates, whereas the inter-laboratory variation (indicating reproducibility) was determined by calculating the standard deviation between laboratories (sR) and the corresponding coefficient of variation (CVR). After removal of outlier samples or laboratories, the mean CVr values for LU and PU test samples ranged from 2.1–3.6% (mean: 2.8%) and 2.4–3.7% (mean: 3.3%), respectively, indicating good repeatability for the determination of 3-HPMA in both sample types. CVR for LU and PU test samples ranged from 9.1–31.9% (mean: 18.8%) and 13.9–27.0% (mean: 18.5%), respectively, indicating limited reproducibility in 3-HPMA analysis for both sample types. Re-calculation of the PU results by applying an embedded calibration (EC), derived from the reported peak areas for the LU test samples, somewhat improved the CVR values (range: 9.6–28.8%, mean: 16.7%). |
topic |
Inter-laboratory comparison 3-hydroxypropyl-mercapturic acid (3-HPMA) intra-laboratory variation inter-laboratory variation repeatability reproducibility |
url |
http://www.degruyter.com/view/j/cttr.2017.27.issue-5/cttr-2016-0006/cttr-2016-0006.xml?format=INT |
work_keys_str_mv |
AT scherergerhard aninterlaboratorycomparisonfortheurinaryacroleinbiomarker3hydroxypropylmercapturicacid3hpma AT hellerwolfdieter aninterlaboratorycomparisonfortheurinaryacroleinbiomarker3hydroxypropylmercapturicacid3hpma AT mcewanmichael aninterlaboratorycomparisonfortheurinaryacroleinbiomarker3hydroxypropylmercapturicacid3hpma AT goenthomas aninterlaboratorycomparisonfortheurinaryacroleinbiomarker3hydroxypropylmercapturicacid3hpma AT jozapeter aninterlaboratorycomparisonfortheurinaryacroleinbiomarker3hydroxypropylmercapturicacid3hpma AT liunan aninterlaboratorycomparisonfortheurinaryacroleinbiomarker3hydroxypropylmercapturicacid3hpma AT newlandkirk aninterlaboratorycomparisonfortheurinaryacroleinbiomarker3hydroxypropylmercapturicacid3hpma AT schettgenthomas aninterlaboratorycomparisonfortheurinaryacroleinbiomarker3hydroxypropylmercapturicacid3hpma AT wangsheng aninterlaboratorycomparisonfortheurinaryacroleinbiomarker3hydroxypropylmercapturicacid3hpma AT sohnhyungok aninterlaboratorycomparisonfortheurinaryacroleinbiomarker3hydroxypropylmercapturicacid3hpma AT troudevalerie aninterlaboratorycomparisonfortheurinaryacroleinbiomarker3hydroxypropylmercapturicacid3hpma AT yukidai aninterlaboratorycomparisonfortheurinaryacroleinbiomarker3hydroxypropylmercapturicacid3hpma AT zhengsaijing aninterlaboratorycomparisonfortheurinaryacroleinbiomarker3hydroxypropylmercapturicacid3hpma AT zhouguojun aninterlaboratorycomparisonfortheurinaryacroleinbiomarker3hydroxypropylmercapturicacid3hpma AT scherergerhard interlaboratorycomparisonfortheurinaryacroleinbiomarker3hydroxypropylmercapturicacid3hpma AT hellerwolfdieter interlaboratorycomparisonfortheurinaryacroleinbiomarker3hydroxypropylmercapturicacid3hpma AT mcewanmichael interlaboratorycomparisonfortheurinaryacroleinbiomarker3hydroxypropylmercapturicacid3hpma AT goenthomas interlaboratorycomparisonfortheurinaryacroleinbiomarker3hydroxypropylmercapturicacid3hpma AT jozapeter interlaboratorycomparisonfortheurinaryacroleinbiomarker3hydroxypropylmercapturicacid3hpma AT liunan interlaboratorycomparisonfortheurinaryacroleinbiomarker3hydroxypropylmercapturicacid3hpma AT newlandkirk interlaboratorycomparisonfortheurinaryacroleinbiomarker3hydroxypropylmercapturicacid3hpma AT schettgenthomas interlaboratorycomparisonfortheurinaryacroleinbiomarker3hydroxypropylmercapturicacid3hpma AT wangsheng interlaboratorycomparisonfortheurinaryacroleinbiomarker3hydroxypropylmercapturicacid3hpma AT sohnhyungok interlaboratorycomparisonfortheurinaryacroleinbiomarker3hydroxypropylmercapturicacid3hpma AT troudevalerie interlaboratorycomparisonfortheurinaryacroleinbiomarker3hydroxypropylmercapturicacid3hpma AT yukidai interlaboratorycomparisonfortheurinaryacroleinbiomarker3hydroxypropylmercapturicacid3hpma AT zhengsaijing interlaboratorycomparisonfortheurinaryacroleinbiomarker3hydroxypropylmercapturicacid3hpma AT zhouguojun interlaboratorycomparisonfortheurinaryacroleinbiomarker3hydroxypropylmercapturicacid3hpma |
_version_ |
1725883346947407872 |