Comparison of visual outcomes after bilateral implantation of a diffractive trifocal intraocular lens and blended implantation of an extended depth of focus intraocular lens with a diffractive bifocal intraocular lens

André Lins de Medeiros,1–4 André Gustavo de Araújo Rolim,1,2 Antonio Francisco Pimenta Motta,2,5 Bruna Vieira Ventura,3,6 César Vilar,1,2,7 Mário Augusto Pereira Dias Chaves,1–3,8 Pedro Carlos Carricondo,2,5 Wilson Takashi Hi...

Full description

Bibliographic Details
Main Authors: de Medeiros AL, de Araujo Rolim AG, Motta AFP, Ventura BV, Vilar C, Chaves MAPD, Carricondo PC, Hida WT
Format: Article
Language:English
Published: Dove Medical Press 2017-10-01
Series:Clinical Ophthalmology
Subjects:
Online Access:https://www.dovepress.com/comparison-of-visual-outcomes-after-bilateral-implantation-of-a-diffra-peer-reviewed-article-OPTH
id doaj-6344531b4c454ac29546435ce84fb6c9
record_format Article
spelling doaj-6344531b4c454ac29546435ce84fb6c92020-11-24T23:40:09ZengDove Medical PressClinical Ophthalmology1177-54832017-10-01Volume 111911191635340Comparison of visual outcomes after bilateral implantation of a diffractive trifocal intraocular lens and blended implantation of an extended depth of focus intraocular lens with a diffractive bifocal intraocular lensde Medeiros ALde Araujo Rolim AGMotta AFPVentura BVVilar CChaves MAPDCarricondo PCHida WTAndré Lins de Medeiros,1–4 André Gustavo de Araújo Rolim,1,2 Antonio Francisco Pimenta Motta,2,5 Bruna Vieira Ventura,3,6 César Vilar,1,2,7 Mário Augusto Pereira Dias Chaves,1–3,8 Pedro Carlos Carricondo,2,5 Wilson Takashi Hida1,2,5 1Cataract Department, Hospital Oftalmológico de Brasília, 2Cataract Department, Centro de Estudos Oftalmológicos Renato Ambrósio, Brasília, 3Cataract Department, Fundação Altino Ventura, Recife, Brazil; 4Cataract Department, University of Edinburgh, Edinburgh, UK; 5Cataract Department, Universidade de São Paulo, São Paulo, 6Cataract Department, Hospital de Olhos de Pernambuco, Recife, 7Cataract Department, Hospital de Olhos Francisco Vilar, Teresina, 8Cataract Department, ProVisão, João Pessoa, Brazil Purpose: The purpose of this study was to compare the visual outcomes and subjective visual quality between bilateral implantation of a diffractive trifocal intraocular lens, Alcon Acrysof IQ® PanOptix® TNFT00 (group A), and blended implantation of an extended depth of focus lens, J&J Tecnis Symfony® ZXR00 with a diffractive bifocal intraocular lens, J&J Vision Tecnis® ZMB00 (group B).Methods: This prospective, nonrandomized, consecutive, comparative study included the assessment of 40 eyes in 20 patients implanted with multifocal intraocular lens. Exclusion criteria were existence of any corneal, retina, or optic nerve disease, previous eye surgery, illiteracy, previous refractive surgery, high axial myopia, expected postoperative corneal astigmatism of >1.00 cylindrical diopter (D), and intraoperative or postoperative complications. Binocular visual acuity was tested in all cases. Ophthalmological evaluation included the measurement of uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected near visual acuity (UNVA), and uncorrected intermediate visual acuity (UIVA), with the analysis of contrast sensitivity (CS), and visual defocus curve.Results: Postoperative UDVA was 0.01 and −0.096 logMAR (p<0.01) in groups A and B, respectively; postoperative CDVA was −0.07 and −0.16 logMAR (p<0.01) in groups A and B, respectively; UIVA was 0.14 and 0.20 logMAR (p<0.01) in groups A and B, respectively; UNVA was −0.03 and 0.11 logMAR (p<0.01) in groups A and B, respectively. Under photopic conditions group B had better CS at low frequencies with and without glare.Conclusion: Both groups promoted good quality of vision for long, intermediate, and short distances. Group B exhibited a better performance for very short distances and for intermediate and long distances ≥−1.50 D of vergence. Group A exhibited a better performance for UIVA at 60 cm and for UNVA at 40 cm. Keywords: trifocal, multifocal, pseudophakia, cataracthttps://www.dovepress.com/comparison-of-visual-outcomes-after-bilateral-implantation-of-a-diffra-peer-reviewed-article-OPTHLensesIntraocularCataractPseudophakia
collection DOAJ
language English
format Article
sources DOAJ
author de Medeiros AL
de Araujo Rolim AG
Motta AFP
Ventura BV
Vilar C
Chaves MAPD
Carricondo PC
Hida WT
spellingShingle de Medeiros AL
de Araujo Rolim AG
Motta AFP
Ventura BV
Vilar C
Chaves MAPD
Carricondo PC
Hida WT
Comparison of visual outcomes after bilateral implantation of a diffractive trifocal intraocular lens and blended implantation of an extended depth of focus intraocular lens with a diffractive bifocal intraocular lens
Clinical Ophthalmology
Lenses
Intraocular
Cataract
Pseudophakia
author_facet de Medeiros AL
de Araujo Rolim AG
Motta AFP
Ventura BV
Vilar C
Chaves MAPD
Carricondo PC
Hida WT
author_sort de Medeiros AL
title Comparison of visual outcomes after bilateral implantation of a diffractive trifocal intraocular lens and blended implantation of an extended depth of focus intraocular lens with a diffractive bifocal intraocular lens
title_short Comparison of visual outcomes after bilateral implantation of a diffractive trifocal intraocular lens and blended implantation of an extended depth of focus intraocular lens with a diffractive bifocal intraocular lens
title_full Comparison of visual outcomes after bilateral implantation of a diffractive trifocal intraocular lens and blended implantation of an extended depth of focus intraocular lens with a diffractive bifocal intraocular lens
title_fullStr Comparison of visual outcomes after bilateral implantation of a diffractive trifocal intraocular lens and blended implantation of an extended depth of focus intraocular lens with a diffractive bifocal intraocular lens
title_full_unstemmed Comparison of visual outcomes after bilateral implantation of a diffractive trifocal intraocular lens and blended implantation of an extended depth of focus intraocular lens with a diffractive bifocal intraocular lens
title_sort comparison of visual outcomes after bilateral implantation of a diffractive trifocal intraocular lens and blended implantation of an extended depth of focus intraocular lens with a diffractive bifocal intraocular lens
publisher Dove Medical Press
series Clinical Ophthalmology
issn 1177-5483
publishDate 2017-10-01
description André Lins de Medeiros,1–4 André Gustavo de Araújo Rolim,1,2 Antonio Francisco Pimenta Motta,2,5 Bruna Vieira Ventura,3,6 César Vilar,1,2,7 Mário Augusto Pereira Dias Chaves,1–3,8 Pedro Carlos Carricondo,2,5 Wilson Takashi Hida1,2,5 1Cataract Department, Hospital Oftalmológico de Brasília, 2Cataract Department, Centro de Estudos Oftalmológicos Renato Ambrósio, Brasília, 3Cataract Department, Fundação Altino Ventura, Recife, Brazil; 4Cataract Department, University of Edinburgh, Edinburgh, UK; 5Cataract Department, Universidade de São Paulo, São Paulo, 6Cataract Department, Hospital de Olhos de Pernambuco, Recife, 7Cataract Department, Hospital de Olhos Francisco Vilar, Teresina, 8Cataract Department, ProVisão, João Pessoa, Brazil Purpose: The purpose of this study was to compare the visual outcomes and subjective visual quality between bilateral implantation of a diffractive trifocal intraocular lens, Alcon Acrysof IQ® PanOptix® TNFT00 (group A), and blended implantation of an extended depth of focus lens, J&J Tecnis Symfony® ZXR00 with a diffractive bifocal intraocular lens, J&J Vision Tecnis® ZMB00 (group B).Methods: This prospective, nonrandomized, consecutive, comparative study included the assessment of 40 eyes in 20 patients implanted with multifocal intraocular lens. Exclusion criteria were existence of any corneal, retina, or optic nerve disease, previous eye surgery, illiteracy, previous refractive surgery, high axial myopia, expected postoperative corneal astigmatism of >1.00 cylindrical diopter (D), and intraoperative or postoperative complications. Binocular visual acuity was tested in all cases. Ophthalmological evaluation included the measurement of uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected near visual acuity (UNVA), and uncorrected intermediate visual acuity (UIVA), with the analysis of contrast sensitivity (CS), and visual defocus curve.Results: Postoperative UDVA was 0.01 and −0.096 logMAR (p<0.01) in groups A and B, respectively; postoperative CDVA was −0.07 and −0.16 logMAR (p<0.01) in groups A and B, respectively; UIVA was 0.14 and 0.20 logMAR (p<0.01) in groups A and B, respectively; UNVA was −0.03 and 0.11 logMAR (p<0.01) in groups A and B, respectively. Under photopic conditions group B had better CS at low frequencies with and without glare.Conclusion: Both groups promoted good quality of vision for long, intermediate, and short distances. Group B exhibited a better performance for very short distances and for intermediate and long distances ≥−1.50 D of vergence. Group A exhibited a better performance for UIVA at 60 cm and for UNVA at 40 cm. Keywords: trifocal, multifocal, pseudophakia, cataract
topic Lenses
Intraocular
Cataract
Pseudophakia
url https://www.dovepress.com/comparison-of-visual-outcomes-after-bilateral-implantation-of-a-diffra-peer-reviewed-article-OPTH
work_keys_str_mv AT demedeirosal comparisonofvisualoutcomesafterbilateralimplantationofadiffractivetrifocalintraocularlensandblendedimplantationofanextendeddepthoffocusintraocularlenswithadiffractivebifocalintraocularlens
AT dearaujorolimag comparisonofvisualoutcomesafterbilateralimplantationofadiffractivetrifocalintraocularlensandblendedimplantationofanextendeddepthoffocusintraocularlenswithadiffractivebifocalintraocularlens
AT mottaafp comparisonofvisualoutcomesafterbilateralimplantationofadiffractivetrifocalintraocularlensandblendedimplantationofanextendeddepthoffocusintraocularlenswithadiffractivebifocalintraocularlens
AT venturabv comparisonofvisualoutcomesafterbilateralimplantationofadiffractivetrifocalintraocularlensandblendedimplantationofanextendeddepthoffocusintraocularlenswithadiffractivebifocalintraocularlens
AT vilarc comparisonofvisualoutcomesafterbilateralimplantationofadiffractivetrifocalintraocularlensandblendedimplantationofanextendeddepthoffocusintraocularlenswithadiffractivebifocalintraocularlens
AT chavesmapd comparisonofvisualoutcomesafterbilateralimplantationofadiffractivetrifocalintraocularlensandblendedimplantationofanextendeddepthoffocusintraocularlenswithadiffractivebifocalintraocularlens
AT carricondopc comparisonofvisualoutcomesafterbilateralimplantationofadiffractivetrifocalintraocularlensandblendedimplantationofanextendeddepthoffocusintraocularlenswithadiffractivebifocalintraocularlens
AT hidawt comparisonofvisualoutcomesafterbilateralimplantationofadiffractivetrifocalintraocularlensandblendedimplantationofanextendeddepthoffocusintraocularlenswithadiffractivebifocalintraocularlens
_version_ 1725510790554845184