Evaluation of dried blood spots collected on filter papers from three manufacturers stored at ambient temperature for application in HIV-1 drug resistance monitoring.

As more HIV-infected people gain access to antiretroviral therapy (ART), monitoring HIV drug resistance (HIVDR) becomes essential to combat both acquired and transmitted HIVDR. Studies have demonstrated dried blood spots (DBS) are a suitable alternative in HIVDR monitoring using DBS collected on Wha...

Full description

Bibliographic Details
Main Authors: Erin K Rottinghaus, R Suzanne Beard, Ebi Bile, Mosetsanagape Modukanele, Maruping Maruping, Madisa Mine, John Nkengasong, Chunfu Yang
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2014-01-01
Series:PLoS ONE
Online Access:http://europepmc.org/articles/PMC4193826?pdf=render
id doaj-6320a848b79b40ddaa664d3cfe7dcf61
record_format Article
spelling doaj-6320a848b79b40ddaa664d3cfe7dcf612020-11-24T21:34:05ZengPublic Library of Science (PLoS)PLoS ONE1932-62032014-01-01910e10906010.1371/journal.pone.0109060Evaluation of dried blood spots collected on filter papers from three manufacturers stored at ambient temperature for application in HIV-1 drug resistance monitoring.Erin K RottinghausR Suzanne BeardEbi BileMosetsanagape ModukaneleMaruping MarupingMadisa MineJohn NkengasongChunfu YangAs more HIV-infected people gain access to antiretroviral therapy (ART), monitoring HIV drug resistance (HIVDR) becomes essential to combat both acquired and transmitted HIVDR. Studies have demonstrated dried blood spots (DBS) are a suitable alternative in HIVDR monitoring using DBS collected on Whatman 903 (W-903). In this study, we sought to evaluate two other commercially available filter papers, Ahlstrom 226 (A-226) and Munktell TFN (M-TFN), for HIVDR genotyping following ambient temperature storage. DBS were prepared from remnant blood specimens collected from 334 ART patients and stored at ambient temperature for a median time of 30 days. HIV-1 viral load was determined using NucliSENS EasyQ® HIV-1 v2.0 RUO test kits prior to genotyping of the protease and reverse transcriptase regions of the HIV-1 pol gene using an in-house assay. Among the DBS tested, 26 specimens had a viral load ≥ 1000 copies/mL in all three types of filter paper and were included in the genotyping analysis. Genotyping efficiencies were similar between DBS collected on W-903 (92.3%), A-226 (88.5%), and M-TFN (92.3%) filter papers (P = 1.00). We identified 50 DR-associated mutations in DBS collected on W-903, 33 in DBS collected on A-226, and 48 in DBS collected on M-TFN, resulting in mutation detection sensitivities of 66.0% for A-226 and 88.0% for M-TFN when compared to W-903. Our data indicate that differences among filter papers may exist at this storage condition and warrant further studies evaluating filter paper type for HIVDR monitoring.http://europepmc.org/articles/PMC4193826?pdf=render
collection DOAJ
language English
format Article
sources DOAJ
author Erin K Rottinghaus
R Suzanne Beard
Ebi Bile
Mosetsanagape Modukanele
Maruping Maruping
Madisa Mine
John Nkengasong
Chunfu Yang
spellingShingle Erin K Rottinghaus
R Suzanne Beard
Ebi Bile
Mosetsanagape Modukanele
Maruping Maruping
Madisa Mine
John Nkengasong
Chunfu Yang
Evaluation of dried blood spots collected on filter papers from three manufacturers stored at ambient temperature for application in HIV-1 drug resistance monitoring.
PLoS ONE
author_facet Erin K Rottinghaus
R Suzanne Beard
Ebi Bile
Mosetsanagape Modukanele
Maruping Maruping
Madisa Mine
John Nkengasong
Chunfu Yang
author_sort Erin K Rottinghaus
title Evaluation of dried blood spots collected on filter papers from three manufacturers stored at ambient temperature for application in HIV-1 drug resistance monitoring.
title_short Evaluation of dried blood spots collected on filter papers from three manufacturers stored at ambient temperature for application in HIV-1 drug resistance monitoring.
title_full Evaluation of dried blood spots collected on filter papers from three manufacturers stored at ambient temperature for application in HIV-1 drug resistance monitoring.
title_fullStr Evaluation of dried blood spots collected on filter papers from three manufacturers stored at ambient temperature for application in HIV-1 drug resistance monitoring.
title_full_unstemmed Evaluation of dried blood spots collected on filter papers from three manufacturers stored at ambient temperature for application in HIV-1 drug resistance monitoring.
title_sort evaluation of dried blood spots collected on filter papers from three manufacturers stored at ambient temperature for application in hiv-1 drug resistance monitoring.
publisher Public Library of Science (PLoS)
series PLoS ONE
issn 1932-6203
publishDate 2014-01-01
description As more HIV-infected people gain access to antiretroviral therapy (ART), monitoring HIV drug resistance (HIVDR) becomes essential to combat both acquired and transmitted HIVDR. Studies have demonstrated dried blood spots (DBS) are a suitable alternative in HIVDR monitoring using DBS collected on Whatman 903 (W-903). In this study, we sought to evaluate two other commercially available filter papers, Ahlstrom 226 (A-226) and Munktell TFN (M-TFN), for HIVDR genotyping following ambient temperature storage. DBS were prepared from remnant blood specimens collected from 334 ART patients and stored at ambient temperature for a median time of 30 days. HIV-1 viral load was determined using NucliSENS EasyQ® HIV-1 v2.0 RUO test kits prior to genotyping of the protease and reverse transcriptase regions of the HIV-1 pol gene using an in-house assay. Among the DBS tested, 26 specimens had a viral load ≥ 1000 copies/mL in all three types of filter paper and were included in the genotyping analysis. Genotyping efficiencies were similar between DBS collected on W-903 (92.3%), A-226 (88.5%), and M-TFN (92.3%) filter papers (P = 1.00). We identified 50 DR-associated mutations in DBS collected on W-903, 33 in DBS collected on A-226, and 48 in DBS collected on M-TFN, resulting in mutation detection sensitivities of 66.0% for A-226 and 88.0% for M-TFN when compared to W-903. Our data indicate that differences among filter papers may exist at this storage condition and warrant further studies evaluating filter paper type for HIVDR monitoring.
url http://europepmc.org/articles/PMC4193826?pdf=render
work_keys_str_mv AT erinkrottinghaus evaluationofdriedbloodspotscollectedonfilterpapersfromthreemanufacturersstoredatambienttemperatureforapplicationinhiv1drugresistancemonitoring
AT rsuzannebeard evaluationofdriedbloodspotscollectedonfilterpapersfromthreemanufacturersstoredatambienttemperatureforapplicationinhiv1drugresistancemonitoring
AT ebibile evaluationofdriedbloodspotscollectedonfilterpapersfromthreemanufacturersstoredatambienttemperatureforapplicationinhiv1drugresistancemonitoring
AT mosetsanagapemodukanele evaluationofdriedbloodspotscollectedonfilterpapersfromthreemanufacturersstoredatambienttemperatureforapplicationinhiv1drugresistancemonitoring
AT marupingmaruping evaluationofdriedbloodspotscollectedonfilterpapersfromthreemanufacturersstoredatambienttemperatureforapplicationinhiv1drugresistancemonitoring
AT madisamine evaluationofdriedbloodspotscollectedonfilterpapersfromthreemanufacturersstoredatambienttemperatureforapplicationinhiv1drugresistancemonitoring
AT johnnkengasong evaluationofdriedbloodspotscollectedonfilterpapersfromthreemanufacturersstoredatambienttemperatureforapplicationinhiv1drugresistancemonitoring
AT chunfuyang evaluationofdriedbloodspotscollectedonfilterpapersfromthreemanufacturersstoredatambienttemperatureforapplicationinhiv1drugresistancemonitoring
_version_ 1725950555665203200