Acute Urinary Obstruction in a Tetraplegic Patient from Misplacement of Catheter in Urethra
Main Authors: | Subramanian Vaidyanathan, Gurpreet Singh, Peter L. Hughes, Bakul M. Soni |
---|---|
Format: | Article |
Language: | English |
Published: |
SAGE Publishing
2016-01-01
|
Series: | Clinical Medicine Insights: Case Reports |
Online Access: | http://www.la-press.com/acute-urinary-obstruction-in-a-tetraplegic-patient-from-misplacement-o-article-a5310 |
Similar Items
-
Acute Urinary Obstruction in a Tetraplegic Patient from Misplacement of Catheter in Urethra
by: Subramanian Vaidyanathan, et al.
Published: (2016-09-01) -
Severe Ventral Erosion of Penis Caused by Indwelling Urethral Catheter and Inflation of Foley Balloon in Urethra—Need to Create List of “Never Events in Spinal Cord Injury” in order to Prevent These Complications from Happening in Paraplegic and Tetraplegic Patients
by: Subramanian Vaidyanathan, et al.
Published: (2010-01-01) -
Postoperative Complications Leading to Death after Coagulum Pyelolithotomy in a Tetraplegic Patient: Can We Prevent Prolonged Ileus, Recurrent Intestinal Obstruction due to Adhesions Requiring Laparotomies, Chest Infection Warranting Tracheostomy, and Mechanical Ventilation?
by: Subramanian Vaidyanathan, et al.
Published: (2013-01-01) -
Urinary retention and acute kidney injury in a tetraplegic patient using condom catheter after partying: a preventable complication
by: Vaidyanathan S, et al.
Published: (2015-10-01) -
A Simple Radiological Technique for Demonstration of Incorrect Positioning of a Foley Catheter with Balloon Inflated in the Urethra of a Male Spinal Cord Injury Patient
by: Subramanian Vaidyanathan, et al.