Placement of a double-lumen tube using LMA C Trach and an exchanger catheter in difficult airway intubation -A case report-

During insertion of the double lumen tube in patients with cervical vertebral fixation, the cervical neutral position should be maintained. Although flexible fiberoptic bronchoscopic intubation is the gold standard, novel techniques are needed to facilitate intubation of patients with cervical verte...

Full description

Bibliographic Details
Main Author: Lale Karabiyik
Format: Article
Language:English
Published: Korean Society of Anesthesiologists 2012-06-01
Series:Korean Journal of Anesthesiology
Subjects:
Online Access:http://ekja.org/upload/pdf/kjae-62-565.pdf
id doaj-620faec5119c4b6bacb059c6032c51a7
record_format Article
spelling doaj-620faec5119c4b6bacb059c6032c51a72020-11-25T03:39:15ZengKorean Society of AnesthesiologistsKorean Journal of Anesthesiology2005-64192005-75632012-06-0162656556710.4097/kjae.2012.62.6.5657362Placement of a double-lumen tube using LMA C Trach and an exchanger catheter in difficult airway intubation -A case report-Lale Karabiyik0Department of Anesthesiology and Intensive Care, Gazi University School of Medicine, Ankara, Turkey.During insertion of the double lumen tube in patients with cervical vertebral fixation, the cervical neutral position should be maintained. Although flexible fiberoptic bronchoscopic intubation is the gold standard, novel techniques are needed to facilitate intubation of patients with cervical vertebral fixation in neutral position according to institutional capabilities. In this case report, insertion of the double lumen tube in the neutral position using LMA CTrach and an airway exchanger catheter in a thoracotomy patient with extremely limited head and neck motion due to fixation of the cervical vertebrae is presented.http://ekja.org/upload/pdf/kjae-62-565.pdfairway managementdifficult airwayequipmentlaryngeal maskslung separation
collection DOAJ
language English
format Article
sources DOAJ
author Lale Karabiyik
spellingShingle Lale Karabiyik
Placement of a double-lumen tube using LMA C Trach and an exchanger catheter in difficult airway intubation -A case report-
Korean Journal of Anesthesiology
airway management
difficult airway
equipment
laryngeal masks
lung separation
author_facet Lale Karabiyik
author_sort Lale Karabiyik
title Placement of a double-lumen tube using LMA C Trach and an exchanger catheter in difficult airway intubation -A case report-
title_short Placement of a double-lumen tube using LMA C Trach and an exchanger catheter in difficult airway intubation -A case report-
title_full Placement of a double-lumen tube using LMA C Trach and an exchanger catheter in difficult airway intubation -A case report-
title_fullStr Placement of a double-lumen tube using LMA C Trach and an exchanger catheter in difficult airway intubation -A case report-
title_full_unstemmed Placement of a double-lumen tube using LMA C Trach and an exchanger catheter in difficult airway intubation -A case report-
title_sort placement of a double-lumen tube using lma c trach and an exchanger catheter in difficult airway intubation -a case report-
publisher Korean Society of Anesthesiologists
series Korean Journal of Anesthesiology
issn 2005-6419
2005-7563
publishDate 2012-06-01
description During insertion of the double lumen tube in patients with cervical vertebral fixation, the cervical neutral position should be maintained. Although flexible fiberoptic bronchoscopic intubation is the gold standard, novel techniques are needed to facilitate intubation of patients with cervical vertebral fixation in neutral position according to institutional capabilities. In this case report, insertion of the double lumen tube in the neutral position using LMA CTrach and an airway exchanger catheter in a thoracotomy patient with extremely limited head and neck motion due to fixation of the cervical vertebrae is presented.
topic airway management
difficult airway
equipment
laryngeal masks
lung separation
url http://ekja.org/upload/pdf/kjae-62-565.pdf
work_keys_str_mv AT lalekarabiyik placementofadoublelumentubeusinglmactrachandanexchangercatheterindifficultairwayintubationacasereport
_version_ 1724540060030730240