Differences in Power Distribution and Health Risk for the Tool Operator Predicted by Human Physical Models in the ISO 10068:2012 Standard
W pracy przedstawiono sposób oceny modeli fizycznych człowieka z normy ISO 10068:2012. Modele porównano metodą energetyczną, która w prezentowanym przypadku została zrealizowana w dziedzinie rozdziału mocy. Badane modele posiadają w pełni określoną strukturę wewnętrzną, dlatego zwrócono uwagę na roz...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Polish Academy of Sciences
2015-09-01
|
Series: | Archive of Mechanical Engineering |
Subjects: | |
Online Access: | http://www.degruyter.com/view/j/meceng.2015.62.issue-3/meceng-2015-0019/meceng-2015-0019.xml?format=INT |
id |
doaj-61ddab2428164cc2b1e1dd955b97d877 |
---|---|
record_format |
Article |
spelling |
doaj-61ddab2428164cc2b1e1dd955b97d8772020-11-25T03:22:58ZengPolish Academy of SciencesArchive of Mechanical Engineering 2300-18952015-09-0162333334610.1515/meceng-2015-0019meceng-2015-0019Differences in Power Distribution and Health Risk for the Tool Operator Predicted by Human Physical Models in the ISO 10068:2012 StandardDobry Marian W.0Hermann Tomasz1Institute of Applied Mechanics, Faculty of Mechanical Engineering and Management, Poznan University of Technology, PolandInstitute of Applied Mechanics, Faculty of Mechanical Engineering and Management, Poznan University of Technology, PolandW pracy przedstawiono sposób oceny modeli fizycznych człowieka z normy ISO 10068:2012. Modele porównano metodą energetyczną, która w prezentowanym przypadku została zrealizowana w dziedzinie rozdziału mocy. Badane modele posiadają w pełni określoną strukturę wewnętrzną, dlatego zwrócono uwagę na rozdział mocy w tych modelach oraz moc globalną w całym systemie. Przedstawiono proces budowy i modelowania energetycznego systemów Człowiek - Narzędzie. Zaprezentowano również wyniki symulacji oraz powiązano otrzymane wartości z zagrożeniami dla zdrowia człowieka.http://www.degruyter.com/view/j/meceng.2015.62.issue-3/meceng-2015-0019/meceng-2015-0019.xml?format=INThand-arm vibrationsbiomechanical systemenergy method |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Dobry Marian W. Hermann Tomasz |
spellingShingle |
Dobry Marian W. Hermann Tomasz Differences in Power Distribution and Health Risk for the Tool Operator Predicted by Human Physical Models in the ISO 10068:2012 Standard Archive of Mechanical Engineering hand-arm vibrations biomechanical system energy method |
author_facet |
Dobry Marian W. Hermann Tomasz |
author_sort |
Dobry Marian W. |
title |
Differences in Power Distribution and Health Risk for the Tool Operator Predicted by Human Physical Models in the ISO 10068:2012 Standard |
title_short |
Differences in Power Distribution and Health Risk for the Tool Operator Predicted by Human Physical Models in the ISO 10068:2012 Standard |
title_full |
Differences in Power Distribution and Health Risk for the Tool Operator Predicted by Human Physical Models in the ISO 10068:2012 Standard |
title_fullStr |
Differences in Power Distribution and Health Risk for the Tool Operator Predicted by Human Physical Models in the ISO 10068:2012 Standard |
title_full_unstemmed |
Differences in Power Distribution and Health Risk for the Tool Operator Predicted by Human Physical Models in the ISO 10068:2012 Standard |
title_sort |
differences in power distribution and health risk for the tool operator predicted by human physical models in the iso 10068:2012 standard |
publisher |
Polish Academy of Sciences |
series |
Archive of Mechanical Engineering |
issn |
2300-1895 |
publishDate |
2015-09-01 |
description |
W pracy przedstawiono sposób oceny modeli fizycznych człowieka z normy ISO 10068:2012. Modele porównano metodą energetyczną, która w prezentowanym przypadku została zrealizowana w dziedzinie rozdziału mocy. Badane modele posiadają w pełni określoną strukturę wewnętrzną, dlatego zwrócono uwagę na rozdział mocy w tych modelach oraz moc globalną w całym systemie. Przedstawiono proces budowy i modelowania energetycznego systemów Człowiek - Narzędzie. Zaprezentowano również wyniki symulacji oraz powiązano otrzymane wartości z zagrożeniami dla zdrowia człowieka. |
topic |
hand-arm vibrations biomechanical system energy method |
url |
http://www.degruyter.com/view/j/meceng.2015.62.issue-3/meceng-2015-0019/meceng-2015-0019.xml?format=INT |
work_keys_str_mv |
AT dobrymarianw differencesinpowerdistributionandhealthriskforthetooloperatorpredictedbyhumanphysicalmodelsintheiso100682012standard AT hermanntomasz differencesinpowerdistributionandhealthriskforthetooloperatorpredictedbyhumanphysicalmodelsintheiso100682012standard |
_version_ |
1724608562879004672 |