Simultaneous measurement of kidney function by dynamic contrast enhanced MRI and FITC-sinistrin clearance in rats at 3 tesla: initial results.

Glomerular filtration rate (GFR) is an essential parameter of kidney function which can be measured by dynamic contrast enhanced magnetic resonance imaging (MRI-GFR) and transcutaneous approaches based on fluorescent tracer molecules (optical-GFR). In an initial study comparing both techniques in se...

Full description

Bibliographic Details
Main Authors: Frank G Zöllner, Daniel Schock-Kusch, Sandra Bäcker, Sabine Neudecker, Norbert Gretz, Lothar R Schad
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2013-01-01
Series:PLoS ONE
Online Access:https://www.ncbi.nlm.nih.gov/pmc/articles/pmid/24260332/?tool=EBI
id doaj-61a6db549bdd4fbaab3c86ce60dc6c87
record_format Article
spelling doaj-61a6db549bdd4fbaab3c86ce60dc6c872021-03-03T20:18:57ZengPublic Library of Science (PLoS)PLoS ONE1932-62032013-01-01811e7999210.1371/journal.pone.0079992Simultaneous measurement of kidney function by dynamic contrast enhanced MRI and FITC-sinistrin clearance in rats at 3 tesla: initial results.Frank G ZöllnerDaniel Schock-KuschSandra BäckerSabine NeudeckerNorbert GretzLothar R SchadGlomerular filtration rate (GFR) is an essential parameter of kidney function which can be measured by dynamic contrast enhanced magnetic resonance imaging (MRI-GFR) and transcutaneous approaches based on fluorescent tracer molecules (optical-GFR). In an initial study comparing both techniques in separate measurements on the same animal, the correlation of the obtained GFR was poor. The goal of this study was to investigate if a simultaneous measurement was feasible and if thereby, the discrepancies in MRI-GFR and optical-GFR could be reduced. For the experiments healthy and unilateral nephrectomised (UNX) Sprague Dawley (SD) rats were used. The miniaturized fluorescent sensor was fixed on the depilated back of an anesthetized rat. A bolus of 5 mg/100 g b.w. of FITC-sinistrin was intravenously injected. For dynamic contrast enhanced perfusion imaging (DCE-MRI) a 3D time-resolved angiography with stochastic trajectories (TWIST) sequence was used. By means of a one compartment model the excretion half-life (t1/2) of FITC-sinistrin was calculated and converted into GFR. GFR from DCE-MRI was calculated by fitting pixel-wise a two compartment renal filtration model. Mean cortical GFR and GFR by FITC-sinistrin were compared by Bland-Altman plots and pair-wise t-test. Results show that a simultaneous GFR measurement using both techniques is feasible. Mean optical-GFR was 4.34 ± 2.22 ml/min (healthy SD rats) and 2.34 ± 0.90 ml/min (UNX rats) whereas MRI-GFR was 2.10 ± 0.64 ml/min (SD rats) and 1.17 ± 0.38 ml/min (UNX rats). Differences between healthy and UNX rats were significant (p<0.05) and almost equal percentage difference (46.1% and 44.3%) in mean GFR were assessed with both techniques. Overall mean optical-GFR values were approximately twice as high compared to MRI-GFR values. However, compared to a previous study, our results showed a higher agreement. In conclusion, the possibility to use the transcutaneous method in MRI may have a huge impact in improving and validating MRI methods for GFR assessment in animal models.https://www.ncbi.nlm.nih.gov/pmc/articles/pmid/24260332/?tool=EBI
collection DOAJ
language English
format Article
sources DOAJ
author Frank G Zöllner
Daniel Schock-Kusch
Sandra Bäcker
Sabine Neudecker
Norbert Gretz
Lothar R Schad
spellingShingle Frank G Zöllner
Daniel Schock-Kusch
Sandra Bäcker
Sabine Neudecker
Norbert Gretz
Lothar R Schad
Simultaneous measurement of kidney function by dynamic contrast enhanced MRI and FITC-sinistrin clearance in rats at 3 tesla: initial results.
PLoS ONE
author_facet Frank G Zöllner
Daniel Schock-Kusch
Sandra Bäcker
Sabine Neudecker
Norbert Gretz
Lothar R Schad
author_sort Frank G Zöllner
title Simultaneous measurement of kidney function by dynamic contrast enhanced MRI and FITC-sinistrin clearance in rats at 3 tesla: initial results.
title_short Simultaneous measurement of kidney function by dynamic contrast enhanced MRI and FITC-sinistrin clearance in rats at 3 tesla: initial results.
title_full Simultaneous measurement of kidney function by dynamic contrast enhanced MRI and FITC-sinistrin clearance in rats at 3 tesla: initial results.
title_fullStr Simultaneous measurement of kidney function by dynamic contrast enhanced MRI and FITC-sinistrin clearance in rats at 3 tesla: initial results.
title_full_unstemmed Simultaneous measurement of kidney function by dynamic contrast enhanced MRI and FITC-sinistrin clearance in rats at 3 tesla: initial results.
title_sort simultaneous measurement of kidney function by dynamic contrast enhanced mri and fitc-sinistrin clearance in rats at 3 tesla: initial results.
publisher Public Library of Science (PLoS)
series PLoS ONE
issn 1932-6203
publishDate 2013-01-01
description Glomerular filtration rate (GFR) is an essential parameter of kidney function which can be measured by dynamic contrast enhanced magnetic resonance imaging (MRI-GFR) and transcutaneous approaches based on fluorescent tracer molecules (optical-GFR). In an initial study comparing both techniques in separate measurements on the same animal, the correlation of the obtained GFR was poor. The goal of this study was to investigate if a simultaneous measurement was feasible and if thereby, the discrepancies in MRI-GFR and optical-GFR could be reduced. For the experiments healthy and unilateral nephrectomised (UNX) Sprague Dawley (SD) rats were used. The miniaturized fluorescent sensor was fixed on the depilated back of an anesthetized rat. A bolus of 5 mg/100 g b.w. of FITC-sinistrin was intravenously injected. For dynamic contrast enhanced perfusion imaging (DCE-MRI) a 3D time-resolved angiography with stochastic trajectories (TWIST) sequence was used. By means of a one compartment model the excretion half-life (t1/2) of FITC-sinistrin was calculated and converted into GFR. GFR from DCE-MRI was calculated by fitting pixel-wise a two compartment renal filtration model. Mean cortical GFR and GFR by FITC-sinistrin were compared by Bland-Altman plots and pair-wise t-test. Results show that a simultaneous GFR measurement using both techniques is feasible. Mean optical-GFR was 4.34 ± 2.22 ml/min (healthy SD rats) and 2.34 ± 0.90 ml/min (UNX rats) whereas MRI-GFR was 2.10 ± 0.64 ml/min (SD rats) and 1.17 ± 0.38 ml/min (UNX rats). Differences between healthy and UNX rats were significant (p<0.05) and almost equal percentage difference (46.1% and 44.3%) in mean GFR were assessed with both techniques. Overall mean optical-GFR values were approximately twice as high compared to MRI-GFR values. However, compared to a previous study, our results showed a higher agreement. In conclusion, the possibility to use the transcutaneous method in MRI may have a huge impact in improving and validating MRI methods for GFR assessment in animal models.
url https://www.ncbi.nlm.nih.gov/pmc/articles/pmid/24260332/?tool=EBI
work_keys_str_mv AT frankgzollner simultaneousmeasurementofkidneyfunctionbydynamiccontrastenhancedmriandfitcsinistrinclearanceinratsat3teslainitialresults
AT danielschockkusch simultaneousmeasurementofkidneyfunctionbydynamiccontrastenhancedmriandfitcsinistrinclearanceinratsat3teslainitialresults
AT sandrabacker simultaneousmeasurementofkidneyfunctionbydynamiccontrastenhancedmriandfitcsinistrinclearanceinratsat3teslainitialresults
AT sabineneudecker simultaneousmeasurementofkidneyfunctionbydynamiccontrastenhancedmriandfitcsinistrinclearanceinratsat3teslainitialresults
AT norbertgretz simultaneousmeasurementofkidneyfunctionbydynamiccontrastenhancedmriandfitcsinistrinclearanceinratsat3teslainitialresults
AT lotharrschad simultaneousmeasurementofkidneyfunctionbydynamiccontrastenhancedmriandfitcsinistrinclearanceinratsat3teslainitialresults
_version_ 1714822982974570496