Slowing down the corrosion of metal structures using polymeric materials
This article examines the resistance of corrosion-resistant polymeric materials to chemical reagents and the degree of corrosion, taking into account the direction of corrosion processes. One of the main factors that determined the corrosion rate is air humidity and dust released into the atmosphere...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
EDP Sciences
2021-01-01
|
Series: | E3S Web of Conferences |
Online Access: | https://www.e3s-conferences.org/articles/e3sconf/pdf/2021/40/e3sconf_conmechydro2021_02055.pdf |
id |
doaj-614fbcc780834a82b35e4cf4d3cf78cc |
---|---|
record_format |
Article |
spelling |
doaj-614fbcc780834a82b35e4cf4d3cf78cc2021-06-11T07:16:51ZengEDP SciencesE3S Web of Conferences2267-12422021-01-012640205510.1051/e3sconf/202126402055e3sconf_conmechydro2021_02055Slowing down the corrosion of metal structures using polymeric materialsNurkulov Fayzulla0Ziyamukhamedova Umida1Rakhmatov Erkin2Nafasov Jasur3Tashkent Scientific Research Institute of Chemical TechnologyTashkent State Transport UniversityTashkent State Transport UniversityTashkent State Transport UniversityThis article examines the resistance of corrosion-resistant polymeric materials to chemical reagents and the degree of corrosion, taking into account the direction of corrosion processes. One of the main factors that determined the corrosion rate is air humidity and dust released into the atmosphere during industrial emissions. Mixtures based on polymer materials can be used to gum up chemical apparatus and equipment; for corrosion protection, expensive materials are required. The sample is conditioned for 30 months at (23 ± 2) 0С, relative humidity (50 ± 5) %, and the thickness of the sample is determined. Resistance to chemical reagents the change in mass of samples of polymeric materials at a temperature of 35 0C for 3 months was analyzed. It was also found that by determining the corrosion rate (grade St3) by storing steel plates in a different exposure environment for 50 days. As a result, the corrosion rate of steel anti-corrosion coatings is lower than the control sample. According to the data obtained, it was found that the chloro-sulfonated polyethylene compositions are resistant to various organic solvents, acids, alkalis, oxidizing agents, and others.https://www.e3s-conferences.org/articles/e3sconf/pdf/2021/40/e3sconf_conmechydro2021_02055.pdf |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Nurkulov Fayzulla Ziyamukhamedova Umida Rakhmatov Erkin Nafasov Jasur |
spellingShingle |
Nurkulov Fayzulla Ziyamukhamedova Umida Rakhmatov Erkin Nafasov Jasur Slowing down the corrosion of metal structures using polymeric materials E3S Web of Conferences |
author_facet |
Nurkulov Fayzulla Ziyamukhamedova Umida Rakhmatov Erkin Nafasov Jasur |
author_sort |
Nurkulov Fayzulla |
title |
Slowing down the corrosion of metal structures using polymeric materials |
title_short |
Slowing down the corrosion of metal structures using polymeric materials |
title_full |
Slowing down the corrosion of metal structures using polymeric materials |
title_fullStr |
Slowing down the corrosion of metal structures using polymeric materials |
title_full_unstemmed |
Slowing down the corrosion of metal structures using polymeric materials |
title_sort |
slowing down the corrosion of metal structures using polymeric materials |
publisher |
EDP Sciences |
series |
E3S Web of Conferences |
issn |
2267-1242 |
publishDate |
2021-01-01 |
description |
This article examines the resistance of corrosion-resistant polymeric materials to chemical reagents and the degree of corrosion, taking into account the direction of corrosion processes. One of the main factors that determined the corrosion rate is air humidity and dust released into the atmosphere during industrial emissions. Mixtures based on polymer materials can be used to gum up chemical apparatus and equipment; for corrosion protection, expensive materials are required. The sample is conditioned for 30 months at (23 ± 2) 0С, relative humidity (50 ± 5) %, and the thickness of the sample is determined. Resistance to chemical reagents the change in mass of samples of polymeric materials at a temperature of 35 0C for 3 months was analyzed. It was also found that by determining the corrosion rate (grade St3) by storing steel plates in a different exposure environment for 50 days. As a result, the corrosion rate of steel anti-corrosion coatings is lower than the control sample. According to the data obtained, it was found that the chloro-sulfonated polyethylene compositions are resistant to various organic solvents, acids, alkalis, oxidizing agents, and others. |
url |
https://www.e3s-conferences.org/articles/e3sconf/pdf/2021/40/e3sconf_conmechydro2021_02055.pdf |
work_keys_str_mv |
AT nurkulovfayzulla slowingdownthecorrosionofmetalstructuresusingpolymericmaterials AT ziyamukhamedovaumida slowingdownthecorrosionofmetalstructuresusingpolymericmaterials AT rakhmatoverkin slowingdownthecorrosionofmetalstructuresusingpolymericmaterials AT nafasovjasur slowingdownthecorrosionofmetalstructuresusingpolymericmaterials |
_version_ |
1721383123453739008 |