Subpicosecond beam length measurement study based on the TM_{010} mode
This article discusses a beam length measurement technique based on the TM_{010} modes of two cavities in frequency domain. Since the TM_{010} pickup monitor has a much better signal-to-noise ratio (SNR) than the other monitors, it can improve the measuring range and resolution limit of the beam len...
Main Authors: | Zhichu Chen, Weimin Zhou, Yongbin Leng, Luyang Yu, Renxian Yuan |
---|---|
Format: | Article |
Language: | English |
Published: |
American Physical Society
2013-07-01
|
Series: | Physical Review Special Topics. Accelerators and Beams |
Online Access: | http://doi.org/10.1103/PhysRevSTAB.16.072801 |
Similar Items
-
Beam position monitor design for a third generation light source
by: Zhichu Chen, et al.
Published: (2014-11-01) -
Measurement of subpicosecond bunch lengths using coherent Smith-Purcell radiation
by: S. E. Korbly, et al.
Published: (2006-02-01) -
Wakefield measurement using principal component analysis on bunch-by-bunch information during transient state of injection in a storage ring
by: Zhichu Chen, et al.
Published: (2014-11-01) -
Measurement of the high-field Q drop in the TM_{010} and TE_{011} modes in a niobium cavity
by: Gianluigi Ciovati, et al.
Published: (2006-04-01) -
Coherent Smith-Purcell radiation for minimally invasive bunch length measurement at the subpicosecond time scale
by: Philipp Heil, et al.