Accuracy and precision of cap thickness in small incision lenticule extraction
Engin Bilge Ozgurhan,1 Alper Agca,1 Ercument Bozkurt,1 Baran Gencer,2 Ugur Celik,1 Kadir İlker Cankaya,1 Ahmet Demirok,1,3 Omer Faruk Yilmaz41Beyoglu Eye Training and Research Hospital, Istanbul, Turkey; 2Ophthalmology Department, Faculty of Medicine, Çanakkale Onsekiz Mart University, &a...
Main Authors: | , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Dove Medical Press
2013-05-01
|
Series: | Clinical Ophthalmology |
Online Access: | http://www.dovepress.com/accuracy-and-precision-of-cap-thickness-in-small-incision-lenticule-ex-a13104 |
id |
doaj-60c2e40dbf974b0889336541821ecdf0 |
---|---|
record_format |
Article |
spelling |
doaj-60c2e40dbf974b0889336541821ecdf02020-11-24T22:17:15ZengDove Medical PressClinical Ophthalmology1177-54671177-54832013-05-012013default923926Accuracy and precision of cap thickness in small incision lenticule extractionOzgurhan EBAgca ABozkurt EGencer BCelik UCankaya KIDemirok AYilmaz OFEngin Bilge Ozgurhan,1 Alper Agca,1 Ercument Bozkurt,1 Baran Gencer,2 Ugur Celik,1 Kadir İlker Cankaya,1 Ahmet Demirok,1,3 Omer Faruk Yilmaz41Beyoglu Eye Training and Research Hospital, Istanbul, Turkey; 2Ophthalmology Department, Faculty of Medicine, Çanakkale Onsekiz Mart University, Çanakkale, Turkey; 3Department of Ophthalmology, Medeniyet University, Istanbul, Turkey; 4Private practice, Istanbul, TurkeyAims: To report and compare the cap thickness predictability of small incision lenticule extraction (SMILE) and flap thickness of femtosecond laser-assisted in situ keratomileusis (femto-LASIK).Settings and design: Beyoglu Eye Training and Research Hospital, Refractive Surgery Department, Istanbul, Turkey. Retrospective pilot study.Materials and methods: Medical records of patients who had SMILE in one eye and femto-LASIK in the other eye were reviewed. Visante corneal Optical Coherence Tomography (OCT) images at 1 week and 1 month post-surgery were analyzed. Both cap and flap thickness at the temporal edge and the nasal edge were measured and compared to each other.Statistical analyses used: PAWS Statistics 18 and unpaired student t-test were used to compare the groups.Results: The study included 66 eyes of 33 patients (24.7 ± 3.8 years, 20 females and 13 males). Mean flap thickness was 114.88 µm ± 4.96 µm, and mean cap thickness was 114.63 µm ± 5.18 µm. In group 1 (SMILE), cap thickness values were 115.84 µm ± 6.84 µm, 114.75 µm ± 7.36 µm, 113.66 µm ± 6.88 µm, and 114.27 µm ± 6.90 µm in measurement zones 1, 2, 3, and 4, respectively. In group 2 (FemtoLASIK), flap corneal thickness values were 115.96 mmHg ± 7.01 mmHg, 114.72 mmHg ± 7.17 mmHg, 113.54 mmHg ± 6.45 mmHg, and 115.30 mmHg ± 6.64 mmHg in measurement zones 1, 2, 3, and 4, respectively. In both groups, no statistically significant change within the measurement zones was observed.Conclusion: The predictability of cap thickness in SMILE surgery does not differ from the femto-LASIK flaps created using the same femtosecond laser platform.Keywords: SMILE, small incision lenticule extractionhttp://www.dovepress.com/accuracy-and-precision-of-cap-thickness-in-small-incision-lenticule-ex-a13104 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Ozgurhan EB Agca A Bozkurt E Gencer B Celik U Cankaya KI Demirok A Yilmaz OF |
spellingShingle |
Ozgurhan EB Agca A Bozkurt E Gencer B Celik U Cankaya KI Demirok A Yilmaz OF Accuracy and precision of cap thickness in small incision lenticule extraction Clinical Ophthalmology |
author_facet |
Ozgurhan EB Agca A Bozkurt E Gencer B Celik U Cankaya KI Demirok A Yilmaz OF |
author_sort |
Ozgurhan EB |
title |
Accuracy and precision of cap thickness in small incision lenticule extraction |
title_short |
Accuracy and precision of cap thickness in small incision lenticule extraction |
title_full |
Accuracy and precision of cap thickness in small incision lenticule extraction |
title_fullStr |
Accuracy and precision of cap thickness in small incision lenticule extraction |
title_full_unstemmed |
Accuracy and precision of cap thickness in small incision lenticule extraction |
title_sort |
accuracy and precision of cap thickness in small incision lenticule extraction |
publisher |
Dove Medical Press |
series |
Clinical Ophthalmology |
issn |
1177-5467 1177-5483 |
publishDate |
2013-05-01 |
description |
Engin Bilge Ozgurhan,1 Alper Agca,1 Ercument Bozkurt,1 Baran Gencer,2 Ugur Celik,1 Kadir İlker Cankaya,1 Ahmet Demirok,1,3 Omer Faruk Yilmaz41Beyoglu Eye Training and Research Hospital, Istanbul, Turkey; 2Ophthalmology Department, Faculty of Medicine, Çanakkale Onsekiz Mart University, Çanakkale, Turkey; 3Department of Ophthalmology, Medeniyet University, Istanbul, Turkey; 4Private practice, Istanbul, TurkeyAims: To report and compare the cap thickness predictability of small incision lenticule extraction (SMILE) and flap thickness of femtosecond laser-assisted in situ keratomileusis (femto-LASIK).Settings and design: Beyoglu Eye Training and Research Hospital, Refractive Surgery Department, Istanbul, Turkey. Retrospective pilot study.Materials and methods: Medical records of patients who had SMILE in one eye and femto-LASIK in the other eye were reviewed. Visante corneal Optical Coherence Tomography (OCT) images at 1 week and 1 month post-surgery were analyzed. Both cap and flap thickness at the temporal edge and the nasal edge were measured and compared to each other.Statistical analyses used: PAWS Statistics 18 and unpaired student t-test were used to compare the groups.Results: The study included 66 eyes of 33 patients (24.7 ± 3.8 years, 20 females and 13 males). Mean flap thickness was 114.88 µm ± 4.96 µm, and mean cap thickness was 114.63 µm ± 5.18 µm. In group 1 (SMILE), cap thickness values were 115.84 µm ± 6.84 µm, 114.75 µm ± 7.36 µm, 113.66 µm ± 6.88 µm, and 114.27 µm ± 6.90 µm in measurement zones 1, 2, 3, and 4, respectively. In group 2 (FemtoLASIK), flap corneal thickness values were 115.96 mmHg ± 7.01 mmHg, 114.72 mmHg ± 7.17 mmHg, 113.54 mmHg ± 6.45 mmHg, and 115.30 mmHg ± 6.64 mmHg in measurement zones 1, 2, 3, and 4, respectively. In both groups, no statistically significant change within the measurement zones was observed.Conclusion: The predictability of cap thickness in SMILE surgery does not differ from the femto-LASIK flaps created using the same femtosecond laser platform.Keywords: SMILE, small incision lenticule extraction |
url |
http://www.dovepress.com/accuracy-and-precision-of-cap-thickness-in-small-incision-lenticule-ex-a13104 |
work_keys_str_mv |
AT ozgurhaneb accuracyandprecisionofcapthicknessinsmallincisionlenticuleextraction AT agcaa accuracyandprecisionofcapthicknessinsmallincisionlenticuleextraction AT bozkurte accuracyandprecisionofcapthicknessinsmallincisionlenticuleextraction AT gencerb accuracyandprecisionofcapthicknessinsmallincisionlenticuleextraction AT celiku accuracyandprecisionofcapthicknessinsmallincisionlenticuleextraction AT cankayaki accuracyandprecisionofcapthicknessinsmallincisionlenticuleextraction AT demiroka accuracyandprecisionofcapthicknessinsmallincisionlenticuleextraction AT yilmazof accuracyandprecisionofcapthicknessinsmallincisionlenticuleextraction |
_version_ |
1725785732240375808 |