Sequential Injection Analysis for Automation and Evaluation of Drug Liberation Profiles: Clotrimazole Liberation Monitoring
A fully automated sequential injection system was tested in terms of its application in liberation testing, and capabilities and limitations were discussed for clotrimazole liberation from three semisolid formulations. An evaluation based on kinetic profiles obtained in short and longer sampling int...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2021-09-01
|
Series: | Molecules |
Subjects: | |
Online Access: | https://www.mdpi.com/1420-3049/26/18/5538 |
id |
doaj-606137dafe85497b8af9c417013000ff |
---|---|
record_format |
Article |
spelling |
doaj-606137dafe85497b8af9c417013000ff2021-09-26T00:46:17ZengMDPI AGMolecules1420-30492021-09-01265538553810.3390/molecules26185538Sequential Injection Analysis for Automation and Evaluation of Drug Liberation Profiles: Clotrimazole Liberation MonitoringHana Sklenářová0Marek Beran1Lucie Novosvětská2Daniela Šmejkalová3Petr Solich4Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, 500 05 Hradec Králové, Czech RepublicDepartment of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, 500 05 Hradec Králové, Czech RepublicDepartment of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, 500 05 Hradec Králové, Czech RepublicContipro a.s., 561 02 Dolní Dobrouč, Czech RepublicDepartment of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, 500 05 Hradec Králové, Czech RepublicA fully automated sequential injection system was tested in terms of its application in liberation testing, and capabilities and limitations were discussed for clotrimazole liberation from three semisolid formulations. An evaluation based on kinetic profiles obtained in short and longer sampling intervals and steady-state flux values were applied as traditional methods. The obtained clotrimazole liberation profile was faster in the case of Delcore and slower for Clotrimazol AL and Canesten cream commercial formulations. The steady-state flux values for the tested formulations were 52 µg cm<sup>−2</sup> h<sup>−1</sup> for Canesten, 35 µg cm<sup>−2</sup> h<sup>−1</sup> for Clotrimazol AL, and 7.2 µg cm<sup>−2</sup> h<sup>−1</sup> for Delcore measured in 4 min sampling intervals. A simplified approach for the evaluation of the initial rate based on the gradient between the second and third sampling points was used for the first time and was found to correspond well with the results of the conventional methods. A comparison based on the ratio of the steady-state flux and the initial rate values for Canesten and Clotrimazol AL proved the similarity of the obtained results. The proposed alternative was successfully implemented for the comparison of short-term kinetic profiles. Consequently, a faster and simpler approach for dissolution/liberation testing can be used.https://www.mdpi.com/1420-3049/26/18/5538clotrimazoleFranz cellkinetic profileliberation studysequential injection analysis |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Hana Sklenářová Marek Beran Lucie Novosvětská Daniela Šmejkalová Petr Solich |
spellingShingle |
Hana Sklenářová Marek Beran Lucie Novosvětská Daniela Šmejkalová Petr Solich Sequential Injection Analysis for Automation and Evaluation of Drug Liberation Profiles: Clotrimazole Liberation Monitoring Molecules clotrimazole Franz cell kinetic profile liberation study sequential injection analysis |
author_facet |
Hana Sklenářová Marek Beran Lucie Novosvětská Daniela Šmejkalová Petr Solich |
author_sort |
Hana Sklenářová |
title |
Sequential Injection Analysis for Automation and Evaluation of Drug Liberation Profiles: Clotrimazole Liberation Monitoring |
title_short |
Sequential Injection Analysis for Automation and Evaluation of Drug Liberation Profiles: Clotrimazole Liberation Monitoring |
title_full |
Sequential Injection Analysis for Automation and Evaluation of Drug Liberation Profiles: Clotrimazole Liberation Monitoring |
title_fullStr |
Sequential Injection Analysis for Automation and Evaluation of Drug Liberation Profiles: Clotrimazole Liberation Monitoring |
title_full_unstemmed |
Sequential Injection Analysis for Automation and Evaluation of Drug Liberation Profiles: Clotrimazole Liberation Monitoring |
title_sort |
sequential injection analysis for automation and evaluation of drug liberation profiles: clotrimazole liberation monitoring |
publisher |
MDPI AG |
series |
Molecules |
issn |
1420-3049 |
publishDate |
2021-09-01 |
description |
A fully automated sequential injection system was tested in terms of its application in liberation testing, and capabilities and limitations were discussed for clotrimazole liberation from three semisolid formulations. An evaluation based on kinetic profiles obtained in short and longer sampling intervals and steady-state flux values were applied as traditional methods. The obtained clotrimazole liberation profile was faster in the case of Delcore and slower for Clotrimazol AL and Canesten cream commercial formulations. The steady-state flux values for the tested formulations were 52 µg cm<sup>−2</sup> h<sup>−1</sup> for Canesten, 35 µg cm<sup>−2</sup> h<sup>−1</sup> for Clotrimazol AL, and 7.2 µg cm<sup>−2</sup> h<sup>−1</sup> for Delcore measured in 4 min sampling intervals. A simplified approach for the evaluation of the initial rate based on the gradient between the second and third sampling points was used for the first time and was found to correspond well with the results of the conventional methods. A comparison based on the ratio of the steady-state flux and the initial rate values for Canesten and Clotrimazol AL proved the similarity of the obtained results. The proposed alternative was successfully implemented for the comparison of short-term kinetic profiles. Consequently, a faster and simpler approach for dissolution/liberation testing can be used. |
topic |
clotrimazole Franz cell kinetic profile liberation study sequential injection analysis |
url |
https://www.mdpi.com/1420-3049/26/18/5538 |
work_keys_str_mv |
AT hanasklenarova sequentialinjectionanalysisforautomationandevaluationofdrugliberationprofilesclotrimazoleliberationmonitoring AT marekberan sequentialinjectionanalysisforautomationandevaluationofdrugliberationprofilesclotrimazoleliberationmonitoring AT lucienovosvetska sequentialinjectionanalysisforautomationandevaluationofdrugliberationprofilesclotrimazoleliberationmonitoring AT danielasmejkalova sequentialinjectionanalysisforautomationandevaluationofdrugliberationprofilesclotrimazoleliberationmonitoring AT petrsolich sequentialinjectionanalysisforautomationandevaluationofdrugliberationprofilesclotrimazoleliberationmonitoring |
_version_ |
1716869857147879424 |