Determination of luteolin from extracts of Helicteres hirsuta by HPLC
High-performance liquid chromatography coupled with a photodiode array detector (HPLC- DAD) has been reported to quantify isolated compounds. This work was designed, therefore, to develop an HPLC-DAD system to determine luteolin in the extract solutions from Helicteres hirsuta. Luteolin was analyzed...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
HUJOS
2019-07-01
|
Series: | Tạp chí Khoa học Đại học Huế: Khoa học Tự nhiên |
Subjects: | |
Online Access: | http://jos.hueuni.edu.vn/index.php/HUJOS-NS/article/view/5195 |
id |
doaj-6055a0c9c4aa46c5b1561b57580d4507 |
---|---|
record_format |
Article |
spelling |
doaj-6055a0c9c4aa46c5b1561b57580d45072020-11-25T03:59:58ZengHUJOSTạp chí Khoa học Đại học Huế: Khoa học Tự nhiên1859-13882615-96782019-07-011281B434710.26459/hueuni-jns.v128i1B.51954311Determination of luteolin from extracts of Helicteres hirsuta by HPLCLe Trung Hieu0Le Lam Son1Nguyen Minh Nhung2Ho Xuan Anh Vu3Tran Thi Anh Thi4University of Sciences, Hue University, 77 Nguyen Hue St., Hue, VietnamUniversity of Sciences, Hue University, 77 Nguyen Hue St., Hue, VietnamTechnical Center for Quality Measurement Standards, Department of Science and Technology, Thua Thien Hue, VietnamUniversity of Sciences, Hue University, 77 Nguyen Hue St., Hue, VietnamUniversity of Sciences, Hue University, 77 Nguyen Hue St., Hue, VietnamHigh-performance liquid chromatography coupled with a photodiode array detector (HPLC- DAD) has been reported to quantify isolated compounds. This work was designed, therefore, to develop an HPLC-DAD system to determine luteolin in the extract solutions from Helicteres hirsuta. Luteolin was analyzed on an RP-C18 column using a mobile phase including acetonitrile – 0.1% phosphoric acid (v/v) = 1:1 (v/v) with a detecting wavelength of 347 nm, a flow rate of 0.5 mL/min, and a volume of an injected sample of 10 μL. The HPLC system was carried out at ambient temperature. The method shows linearity for luteolin in the range 0.02–1 mg/mL, and the recovery of luteolin is 94.07 ± 0.64 %. This is the first time, the contents of luteolin in methanol extracts from the plant parts of H. hirsuta (including branch, fruit, and aerial parts) were determined with a value of 49.06 ± 0.46, 56.61 ± 0.62 and 91.15 ± .42 µg/g, respectively.http://jos.hueuni.edu.vn/index.php/HUJOS-NS/article/view/5195luteolinhelicteres hirsutahplc |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Le Trung Hieu Le Lam Son Nguyen Minh Nhung Ho Xuan Anh Vu Tran Thi Anh Thi |
spellingShingle |
Le Trung Hieu Le Lam Son Nguyen Minh Nhung Ho Xuan Anh Vu Tran Thi Anh Thi Determination of luteolin from extracts of Helicteres hirsuta by HPLC Tạp chí Khoa học Đại học Huế: Khoa học Tự nhiên luteolin helicteres hirsuta hplc |
author_facet |
Le Trung Hieu Le Lam Son Nguyen Minh Nhung Ho Xuan Anh Vu Tran Thi Anh Thi |
author_sort |
Le Trung Hieu |
title |
Determination of luteolin from extracts of Helicteres hirsuta by HPLC |
title_short |
Determination of luteolin from extracts of Helicteres hirsuta by HPLC |
title_full |
Determination of luteolin from extracts of Helicteres hirsuta by HPLC |
title_fullStr |
Determination of luteolin from extracts of Helicteres hirsuta by HPLC |
title_full_unstemmed |
Determination of luteolin from extracts of Helicteres hirsuta by HPLC |
title_sort |
determination of luteolin from extracts of helicteres hirsuta by hplc |
publisher |
HUJOS |
series |
Tạp chí Khoa học Đại học Huế: Khoa học Tự nhiên |
issn |
1859-1388 2615-9678 |
publishDate |
2019-07-01 |
description |
High-performance liquid chromatography coupled with a photodiode array detector (HPLC- DAD) has been reported to quantify isolated compounds. This work was designed, therefore, to develop an HPLC-DAD system to determine luteolin in the extract solutions from Helicteres hirsuta. Luteolin was analyzed on an RP-C18 column using a mobile phase including acetonitrile – 0.1% phosphoric acid (v/v) = 1:1 (v/v) with a detecting wavelength of 347 nm, a flow rate of 0.5 mL/min, and a volume of an injected sample of 10 μL. The HPLC system was carried out at ambient temperature. The method shows linearity for luteolin in the range 0.02–1 mg/mL, and the recovery of luteolin is 94.07 ± 0.64 %. This is the first time, the contents of luteolin in methanol extracts from the plant parts of H. hirsuta (including branch, fruit, and aerial parts) were determined with a value of 49.06 ± 0.46, 56.61 ± 0.62 and 91.15 ± .42 µg/g, respectively. |
topic |
luteolin helicteres hirsuta hplc |
url |
http://jos.hueuni.edu.vn/index.php/HUJOS-NS/article/view/5195 |
work_keys_str_mv |
AT letrunghieu determinationofluteolinfromextractsofhelictereshirsutabyhplc AT lelamson determinationofluteolinfromextractsofhelictereshirsutabyhplc AT nguyenminhnhung determinationofluteolinfromextractsofhelictereshirsutabyhplc AT hoxuananhvu determinationofluteolinfromextractsofhelictereshirsutabyhplc AT tranthianhthi determinationofluteolinfromextractsofhelictereshirsutabyhplc |
_version_ |
1724452163569057792 |