Dependence of the Contact Resistance on the Design of Stranded Conductors
During the manufacturing process multi-strand conductors are subject to compressive force and rotation moments. The current distribution in the multi-strand conductors is not uniform and is controlled by the transverse resistivity. This is mainly determined by the contact resistance at the strand cr...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2014-07-01
|
Series: | Sensors |
Subjects: | |
Online Access: | http://www.mdpi.com/1424-8220/14/8/13925 |
id |
doaj-603e2a8ea620437fa0cc9b306243c0d8 |
---|---|
record_format |
Article |
spelling |
doaj-603e2a8ea620437fa0cc9b306243c0d82020-11-24T21:46:01ZengMDPI AGSensors1424-82202014-07-01148139251394210.3390/s140813925s140813925Dependence of the Contact Resistance on the Design of Stranded ConductorsYoucef Zeroukhi0Ewa Napieralska-Juszczak1Guillaume Vega2Krzysztof Komeza3Fabrice Morganti4Slawomir Wiak5Lille Nord de France, F-59000 Lille, FranceLille Nord de France, F-59000 Lille, FranceNexans, 62300 Lens, Bd de Marais, FranceInstitute of Mechatronics and Information Systems Technical University of Lodz, Stefanowskiego 18/22, Lodz, PolandLille Nord de France, F-59000 Lille, FranceInstitute of Mechatronics and Information Systems Technical University of Lodz, Stefanowskiego 18/22, Lodz, PolandDuring the manufacturing process multi-strand conductors are subject to compressive force and rotation moments. The current distribution in the multi-strand conductors is not uniform and is controlled by the transverse resistivity. This is mainly determined by the contact resistance at the strand crossovers and inter-strand contact resistance. The surface layer properties, and in particular the crystalline structure and degree of oxidation, are key parameters in determining the transverse resistivity. The experimental set-ups made it possible to find the dependence of contact resistivity as a function of continuous working stresses and cable design. A study based on measurements and numerical simulation is made to identify the contact resistivity functions.http://www.mdpi.com/1424-8220/14/8/13925stranded conductorscontact resistancecable designcable simulationcontact resistance measurement |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Youcef Zeroukhi Ewa Napieralska-Juszczak Guillaume Vega Krzysztof Komeza Fabrice Morganti Slawomir Wiak |
spellingShingle |
Youcef Zeroukhi Ewa Napieralska-Juszczak Guillaume Vega Krzysztof Komeza Fabrice Morganti Slawomir Wiak Dependence of the Contact Resistance on the Design of Stranded Conductors Sensors stranded conductors contact resistance cable design cable simulation contact resistance measurement |
author_facet |
Youcef Zeroukhi Ewa Napieralska-Juszczak Guillaume Vega Krzysztof Komeza Fabrice Morganti Slawomir Wiak |
author_sort |
Youcef Zeroukhi |
title |
Dependence of the Contact Resistance on the Design of Stranded Conductors |
title_short |
Dependence of the Contact Resistance on the Design of Stranded Conductors |
title_full |
Dependence of the Contact Resistance on the Design of Stranded Conductors |
title_fullStr |
Dependence of the Contact Resistance on the Design of Stranded Conductors |
title_full_unstemmed |
Dependence of the Contact Resistance on the Design of Stranded Conductors |
title_sort |
dependence of the contact resistance on the design of stranded conductors |
publisher |
MDPI AG |
series |
Sensors |
issn |
1424-8220 |
publishDate |
2014-07-01 |
description |
During the manufacturing process multi-strand conductors are subject to compressive force and rotation moments. The current distribution in the multi-strand conductors is not uniform and is controlled by the transverse resistivity. This is mainly determined by the contact resistance at the strand crossovers and inter-strand contact resistance. The surface layer properties, and in particular the crystalline structure and degree of oxidation, are key parameters in determining the transverse resistivity. The experimental set-ups made it possible to find the dependence of contact resistivity as a function of continuous working stresses and cable design. A study based on measurements and numerical simulation is made to identify the contact resistivity functions. |
topic |
stranded conductors contact resistance cable design cable simulation contact resistance measurement |
url |
http://www.mdpi.com/1424-8220/14/8/13925 |
work_keys_str_mv |
AT youcefzeroukhi dependenceofthecontactresistanceonthedesignofstrandedconductors AT ewanapieralskajuszczak dependenceofthecontactresistanceonthedesignofstrandedconductors AT guillaumevega dependenceofthecontactresistanceonthedesignofstrandedconductors AT krzysztofkomeza dependenceofthecontactresistanceonthedesignofstrandedconductors AT fabricemorganti dependenceofthecontactresistanceonthedesignofstrandedconductors AT slawomirwiak dependenceofthecontactresistanceonthedesignofstrandedconductors |
_version_ |
1725902525069000704 |