Association between keratoconus disease severity and repeatability in measurements of parameters for the assessment of progressive disease.

BACKGROUND:Progressive keratoconus can lead to severely impaired vision, but there is currently no consensus on the definition of progressive disease. Errors in the measurement of the parameters commonly used to establish progressive disease were evaluated in an attempt to determine the limits at wh...

Full description

Bibliographic Details
Main Authors: Ingemar Gustafsson, Anders Bergström, Anna Cardiakides Myers, Anders Ivarsen, Jesper Hjortdal
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2020-01-01
Series:PLoS ONE
Online Access:https://doi.org/10.1371/journal.pone.0228992
id doaj-5ffd0dc5991a4117974eb3e99e59d6a3
record_format Article
spelling doaj-5ffd0dc5991a4117974eb3e99e59d6a32021-03-03T21:29:32ZengPublic Library of Science (PLoS)PLoS ONE1932-62032020-01-01152e022899210.1371/journal.pone.0228992Association between keratoconus disease severity and repeatability in measurements of parameters for the assessment of progressive disease.Ingemar GustafssonAnders BergströmAnna Cardiakides MyersAnders IvarsenJesper HjortdalBACKGROUND:Progressive keratoconus can lead to severely impaired vision, but there is currently no consensus on the definition of progressive disease. Errors in the measurement of the parameters commonly used to establish progressive disease were evaluated in an attempt to determine the limits at which a true change in the values can be detected. The possible association between measurement error and disease severity was also investigated to evaluate the need for limits based on disease severity. METHODS:Sixty-one eyes were studied in 61 patients with keratoconus. Four replicate measurements were made in each patient using a Scheimpflug-based tomographic system (denoted the PC) and an auto-keratometer (denoted the AK). The repeatability coefficient, i.e., the level below which differences between two measurements are found in 95% of paired observations, was calculated. Patients were further divided into three groups based on disease severity (parameter magnitude). RESULTS:Increasing magnitude of all the keratometric parameters investigated was significantly associated with increasing measurement errors, and thus worse repeatability. The maximum keratometry value (Kmax) was the least repeatable parameter (1.23 D, 95% CI 1.11-1.35 D) and showed the strongest association between parameter magnitude and measurement error. The repeatability coefficient ranged between 0.32 and 1.62 D, depending on disease severity. The most repeatable parameter was the flattest central keratometry value (K1), measured with the PC (0.51 D, 95% CI 0.46-0.56 D) and the AK (0.54 D, 95% CI 0.48-0.59 D). K1 showed the weakest association between parameter magnitude and measurement error. The repeatability coefficient for K1 ranged between 0.40 and 0.54 D when using the PC, and between 0.34 and 0.70 D when using the AK in the three groups. CONCLUSIONS:The association between the magnitude of the keratometric parameters and their measurement errors suggests that limits should be based on disease severity to ensure reliable detection of progressive keratoconus. Further studies are, however, required.https://doi.org/10.1371/journal.pone.0228992
collection DOAJ
language English
format Article
sources DOAJ
author Ingemar Gustafsson
Anders Bergström
Anna Cardiakides Myers
Anders Ivarsen
Jesper Hjortdal
spellingShingle Ingemar Gustafsson
Anders Bergström
Anna Cardiakides Myers
Anders Ivarsen
Jesper Hjortdal
Association between keratoconus disease severity and repeatability in measurements of parameters for the assessment of progressive disease.
PLoS ONE
author_facet Ingemar Gustafsson
Anders Bergström
Anna Cardiakides Myers
Anders Ivarsen
Jesper Hjortdal
author_sort Ingemar Gustafsson
title Association between keratoconus disease severity and repeatability in measurements of parameters for the assessment of progressive disease.
title_short Association between keratoconus disease severity and repeatability in measurements of parameters for the assessment of progressive disease.
title_full Association between keratoconus disease severity and repeatability in measurements of parameters for the assessment of progressive disease.
title_fullStr Association between keratoconus disease severity and repeatability in measurements of parameters for the assessment of progressive disease.
title_full_unstemmed Association between keratoconus disease severity and repeatability in measurements of parameters for the assessment of progressive disease.
title_sort association between keratoconus disease severity and repeatability in measurements of parameters for the assessment of progressive disease.
publisher Public Library of Science (PLoS)
series PLoS ONE
issn 1932-6203
publishDate 2020-01-01
description BACKGROUND:Progressive keratoconus can lead to severely impaired vision, but there is currently no consensus on the definition of progressive disease. Errors in the measurement of the parameters commonly used to establish progressive disease were evaluated in an attempt to determine the limits at which a true change in the values can be detected. The possible association between measurement error and disease severity was also investigated to evaluate the need for limits based on disease severity. METHODS:Sixty-one eyes were studied in 61 patients with keratoconus. Four replicate measurements were made in each patient using a Scheimpflug-based tomographic system (denoted the PC) and an auto-keratometer (denoted the AK). The repeatability coefficient, i.e., the level below which differences between two measurements are found in 95% of paired observations, was calculated. Patients were further divided into three groups based on disease severity (parameter magnitude). RESULTS:Increasing magnitude of all the keratometric parameters investigated was significantly associated with increasing measurement errors, and thus worse repeatability. The maximum keratometry value (Kmax) was the least repeatable parameter (1.23 D, 95% CI 1.11-1.35 D) and showed the strongest association between parameter magnitude and measurement error. The repeatability coefficient ranged between 0.32 and 1.62 D, depending on disease severity. The most repeatable parameter was the flattest central keratometry value (K1), measured with the PC (0.51 D, 95% CI 0.46-0.56 D) and the AK (0.54 D, 95% CI 0.48-0.59 D). K1 showed the weakest association between parameter magnitude and measurement error. The repeatability coefficient for K1 ranged between 0.40 and 0.54 D when using the PC, and between 0.34 and 0.70 D when using the AK in the three groups. CONCLUSIONS:The association between the magnitude of the keratometric parameters and their measurement errors suggests that limits should be based on disease severity to ensure reliable detection of progressive keratoconus. Further studies are, however, required.
url https://doi.org/10.1371/journal.pone.0228992
work_keys_str_mv AT ingemargustafsson associationbetweenkeratoconusdiseaseseverityandrepeatabilityinmeasurementsofparametersfortheassessmentofprogressivedisease
AT andersbergstrom associationbetweenkeratoconusdiseaseseverityandrepeatabilityinmeasurementsofparametersfortheassessmentofprogressivedisease
AT annacardiakidesmyers associationbetweenkeratoconusdiseaseseverityandrepeatabilityinmeasurementsofparametersfortheassessmentofprogressivedisease
AT andersivarsen associationbetweenkeratoconusdiseaseseverityandrepeatabilityinmeasurementsofparametersfortheassessmentofprogressivedisease
AT jesperhjortdal associationbetweenkeratoconusdiseaseseverityandrepeatabilityinmeasurementsofparametersfortheassessmentofprogressivedisease
_version_ 1714816615236763648