Quality improvement of monolithic steel fiber concrete floor slabs with void formers
The features of the technology for the monolithic floors construction using void formers have been studied, its disadvantages have been identified and the ways to eliminate them have been proposed. At the first stage of this work, the reasons for the low quality of monolithic floors with void former...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
EDP Sciences
2021-01-01
|
Series: | E3S Web of Conferences |
Subjects: | |
Online Access: | https://www.e3s-conferences.org/articles/e3sconf/pdf/2021/50/e3sconf_stcce2021_06001.pdf |
id |
doaj-5fec05ef663148888a9f0e36f1079542 |
---|---|
record_format |
Article |
spelling |
doaj-5fec05ef663148888a9f0e36f10795422021-06-21T07:49:59ZengEDP SciencesE3S Web of Conferences2267-12422021-01-012740600110.1051/e3sconf/202127406001e3sconf_stcce2021_06001Quality improvement of monolithic steel fiber concrete floor slabs with void formersMukhametrakhimov Rustem0Khuzin AiratKhamidullina Dinara1Kazan State University of Architecture and EngineeringLLC «ProjectStroyMontazh»The features of the technology for the monolithic floors construction using void formers have been studied, its disadvantages have been identified and the ways to eliminate them have been proposed. At the first stage of this work, the reasons for the low quality of monolithic floors with void formers were studied by the method of visual and measuring control, and by comparing with known scientific and industrial data. At the second stage, by the method of systematization the main defects and damages arising in the construction, repair and usage of these floor slabs were classified and ways to eliminate them were proposed. At the third stage, the features of the quality control system, carried out directly during the construction of monolithic floor slabs using void formers, were studied, the composition of operations and control tools were proposed. According to the research results, it was found that the use of steel-fiber concrete in floors with non-removable void formers allows to reduce the percentage of reinforcement by 9.82%, compared to other known options, and also to reduce the consumption of concrete in comparison with a solid monolithic slab almost by half. The proposed quality control system will improve the efficiency of monolithic floor slabs using void formers.https://www.e3s-conferences.org/articles/e3sconf/pdf/2021/50/e3sconf_stcce2021_06001.pdfconcreteslightweight monolithic floor slabseffective design shapenon-removable void formersfiber concreteone-stage concretingfixatorsdefectsdamagequality controlconstruction technology and organization |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Mukhametrakhimov Rustem Khuzin Airat Khamidullina Dinara |
spellingShingle |
Mukhametrakhimov Rustem Khuzin Airat Khamidullina Dinara Quality improvement of monolithic steel fiber concrete floor slabs with void formers E3S Web of Conferences concretes lightweight monolithic floor slabs effective design shape non-removable void formers fiber concrete one-stage concreting fixators defects damage quality control construction technology and organization |
author_facet |
Mukhametrakhimov Rustem Khuzin Airat Khamidullina Dinara |
author_sort |
Mukhametrakhimov Rustem |
title |
Quality improvement of monolithic steel fiber concrete floor slabs with void formers |
title_short |
Quality improvement of monolithic steel fiber concrete floor slabs with void formers |
title_full |
Quality improvement of monolithic steel fiber concrete floor slabs with void formers |
title_fullStr |
Quality improvement of monolithic steel fiber concrete floor slabs with void formers |
title_full_unstemmed |
Quality improvement of monolithic steel fiber concrete floor slabs with void formers |
title_sort |
quality improvement of monolithic steel fiber concrete floor slabs with void formers |
publisher |
EDP Sciences |
series |
E3S Web of Conferences |
issn |
2267-1242 |
publishDate |
2021-01-01 |
description |
The features of the technology for the monolithic floors construction using void formers have been studied, its disadvantages have been identified and the ways to eliminate them have been proposed. At the first stage of this work, the reasons for the low quality of monolithic floors with void formers were studied by the method of visual and measuring control, and by comparing with known scientific and industrial data. At the second stage, by the method of systematization the main defects and damages arising in the construction, repair and usage of these floor slabs were classified and ways to eliminate them were proposed. At the third stage, the features of the quality control system, carried out directly during the construction of monolithic floor slabs using void formers, were studied, the composition of operations and control tools were proposed. According to the research results, it was found that the use of steel-fiber concrete in floors with non-removable void formers allows to reduce the percentage of reinforcement by 9.82%, compared to other known options, and also to reduce the consumption of concrete in comparison with a solid monolithic slab almost by half. The proposed quality control system will improve the efficiency of monolithic floor slabs using void formers. |
topic |
concretes lightweight monolithic floor slabs effective design shape non-removable void formers fiber concrete one-stage concreting fixators defects damage quality control construction technology and organization |
url |
https://www.e3s-conferences.org/articles/e3sconf/pdf/2021/50/e3sconf_stcce2021_06001.pdf |
work_keys_str_mv |
AT mukhametrakhimovrustem qualityimprovementofmonolithicsteelfiberconcretefloorslabswithvoidformers AT khuzinairat qualityimprovementofmonolithicsteelfiberconcretefloorslabswithvoidformers AT khamidullinadinara qualityimprovementofmonolithicsteelfiberconcretefloorslabswithvoidformers |
_version_ |
1721368634102644736 |