Measurements of Implant Stability Following Sinus Lift: A Pilot Clinical Study

Aim: The aim of this study was to evaluate the implant stability of Bredent Sky Blue implants of different diameters following one stage sinus lift procedure. Material and methods: This study included 9 male patients with an existing indication for unilateral or bilateral sinus lift procedure. As gr...

Full description

Bibliographic Details
Main Authors: Muhamed Ajanović, Adis Hamzić, Selma Tosum, Alma Kamber-Ćesir
Format: Article
Language:English
Published: University of Zagreb. School of Dental Medicine 2015-01-01
Series:Acta Stomatologica Croatica
Subjects:
Online Access:http://hrcak.srce.hr/file/214087
id doaj-5fb0de98e9b246f3b8c8fc99678d02cd
record_format Article
spelling doaj-5fb0de98e9b246f3b8c8fc99678d02cd2020-11-25T00:55:03ZengUniversity of Zagreb. School of Dental MedicineActa Stomatologica Croatica0001-70191846-04102015-01-01493228233Measurements of Implant Stability Following Sinus Lift: A Pilot Clinical StudyMuhamed Ajanović0Adis Hamzić1Selma Tosum2Alma Kamber-Ćesir3Department of Prosthodontics, Sarajevo University, School of Dentistry, Sarajevo, BiHDepartment of Prosthodontics, Sarajevo University, School of Dentistry, Sarajevo, BiHDepartment of Prosthodontics, Sarajevo University, School of Dentistry, Sarajevo, BiHDepartment of Prosthodontics, Sarajevo University, School of Dentistry, Sarajevo, BiHAim: The aim of this study was to evaluate the implant stability of Bredent Sky Blue implants of different diameters following one stage sinus lift procedure. Material and methods: This study included 9 male patients with an existing indication for unilateral or bilateral sinus lift procedure. As grafting materials, combination of allograft material MinerOss® cortical & cancellous and Ossceram nano were used. Results: All implants were considered successful and ISQ levels were measured by Osstell ISQ device. The ISQ values were from 68 to 84. The mean values of stability of Bredent Sky Blue implants of different diameters following one stage sinus lift procedure were 77.73 ± 2.93 (MD) and 77.98 ± 2.72 (VO).http://hrcak.srce.hr/file/214087Dental ImplantationSinus Floor Augmentation
collection DOAJ
language English
format Article
sources DOAJ
author Muhamed Ajanović
Adis Hamzić
Selma Tosum
Alma Kamber-Ćesir
spellingShingle Muhamed Ajanović
Adis Hamzić
Selma Tosum
Alma Kamber-Ćesir
Measurements of Implant Stability Following Sinus Lift: A Pilot Clinical Study
Acta Stomatologica Croatica
Dental Implantation
Sinus Floor Augmentation
author_facet Muhamed Ajanović
Adis Hamzić
Selma Tosum
Alma Kamber-Ćesir
author_sort Muhamed Ajanović
title Measurements of Implant Stability Following Sinus Lift: A Pilot Clinical Study
title_short Measurements of Implant Stability Following Sinus Lift: A Pilot Clinical Study
title_full Measurements of Implant Stability Following Sinus Lift: A Pilot Clinical Study
title_fullStr Measurements of Implant Stability Following Sinus Lift: A Pilot Clinical Study
title_full_unstemmed Measurements of Implant Stability Following Sinus Lift: A Pilot Clinical Study
title_sort measurements of implant stability following sinus lift: a pilot clinical study
publisher University of Zagreb. School of Dental Medicine
series Acta Stomatologica Croatica
issn 0001-7019
1846-0410
publishDate 2015-01-01
description Aim: The aim of this study was to evaluate the implant stability of Bredent Sky Blue implants of different diameters following one stage sinus lift procedure. Material and methods: This study included 9 male patients with an existing indication for unilateral or bilateral sinus lift procedure. As grafting materials, combination of allograft material MinerOss® cortical & cancellous and Ossceram nano were used. Results: All implants were considered successful and ISQ levels were measured by Osstell ISQ device. The ISQ values were from 68 to 84. The mean values of stability of Bredent Sky Blue implants of different diameters following one stage sinus lift procedure were 77.73 ± 2.93 (MD) and 77.98 ± 2.72 (VO).
topic Dental Implantation
Sinus Floor Augmentation
url http://hrcak.srce.hr/file/214087
work_keys_str_mv AT muhamedajanovic measurementsofimplantstabilityfollowingsinusliftapilotclinicalstudy
AT adishamzic measurementsofimplantstabilityfollowingsinusliftapilotclinicalstudy
AT selmatosum measurementsofimplantstabilityfollowingsinusliftapilotclinicalstudy
AT almakambercesir measurementsofimplantstabilityfollowingsinusliftapilotclinicalstudy
_version_ 1725232429267943424