Analysis of Fire Control Hotel in Palembang City

The Regulation of the Minister of Public Works Number: 26 / PRT / M / 2008 about technical requirements of fire protection in buildings and environments has not been implemented optimally in hotels. The purpose of this research is to analyze the fire prevention system of hotel building in Palembang...

Full description

Bibliographic Details
Main Authors: Tiarlina Jimmy, Novrikasari, Sitorus Rico Januar
Format: Article
Language:English
Published: EDP Sciences 2018-01-01
Series:E3S Web of Conferences
Online Access:https://doi.org/10.1051/e3sconf/20186803001
id doaj-5f51bdea86b74815b5765dd73dc2ee8d
record_format Article
spelling doaj-5f51bdea86b74815b5765dd73dc2ee8d2021-04-02T11:14:03ZengEDP SciencesE3S Web of Conferences2267-12422018-01-01680300110.1051/e3sconf/20186803001e3sconf_sricoenv2018_03001Analysis of Fire Control Hotel in Palembang CityTiarlina Jimmy0Novrikasari1Sitorus Rico Januar2Faculty of Environmental Health, Universitas SriwijayaFaculty of Environmental Health, Universitas SriwijayaFaculty of Environmental Health, Universitas SriwijayaThe Regulation of the Minister of Public Works Number: 26 / PRT / M / 2008 about technical requirements of fire protection in buildings and environments has not been implemented optimally in hotels. The purpose of this research is to analyze the fire prevention system of hotel building in Palembang City. The research design was Cross Sectional, sampling technique used Stratified Random Sampling with 31 hotels as the sample. Data analysis used Chi Square test. The result of this research shows that from 31 hotels, 74.2% have good fire prevention system, 58.06% of fire officer access is eligible, 93.55% of water supply is eligible, 83.87% of the tools of rescue is eligible,74.19% of active protection system is eligible, 74.19% of knowledge of fire manager is eligible. The result of statistical analysis showed that there is no correlation between access of fire fighter, water supply and active protection system with the fire prevention system at hotel. The related factors were the tools of rescue; passive protection system; the knowledge of fire safety manager. The conclusions of this research is the related factors that has relation with fire prevention facilities at hotels in Palembang City is the tools of rescue, passive protection system and knowledge of fire safety manager. The writer suggests to improve the fire prevention knowledge for all hotel staff, to inform visitors about the way route of escape, the improvement of routine maintenance and coaching from managerial and the existence of further research on fire prevention system.https://doi.org/10.1051/e3sconf/20186803001
collection DOAJ
language English
format Article
sources DOAJ
author Tiarlina Jimmy
Novrikasari
Sitorus Rico Januar
spellingShingle Tiarlina Jimmy
Novrikasari
Sitorus Rico Januar
Analysis of Fire Control Hotel in Palembang City
E3S Web of Conferences
author_facet Tiarlina Jimmy
Novrikasari
Sitorus Rico Januar
author_sort Tiarlina Jimmy
title Analysis of Fire Control Hotel in Palembang City
title_short Analysis of Fire Control Hotel in Palembang City
title_full Analysis of Fire Control Hotel in Palembang City
title_fullStr Analysis of Fire Control Hotel in Palembang City
title_full_unstemmed Analysis of Fire Control Hotel in Palembang City
title_sort analysis of fire control hotel in palembang city
publisher EDP Sciences
series E3S Web of Conferences
issn 2267-1242
publishDate 2018-01-01
description The Regulation of the Minister of Public Works Number: 26 / PRT / M / 2008 about technical requirements of fire protection in buildings and environments has not been implemented optimally in hotels. The purpose of this research is to analyze the fire prevention system of hotel building in Palembang City. The research design was Cross Sectional, sampling technique used Stratified Random Sampling with 31 hotels as the sample. Data analysis used Chi Square test. The result of this research shows that from 31 hotels, 74.2% have good fire prevention system, 58.06% of fire officer access is eligible, 93.55% of water supply is eligible, 83.87% of the tools of rescue is eligible,74.19% of active protection system is eligible, 74.19% of knowledge of fire manager is eligible. The result of statistical analysis showed that there is no correlation between access of fire fighter, water supply and active protection system with the fire prevention system at hotel. The related factors were the tools of rescue; passive protection system; the knowledge of fire safety manager. The conclusions of this research is the related factors that has relation with fire prevention facilities at hotels in Palembang City is the tools of rescue, passive protection system and knowledge of fire safety manager. The writer suggests to improve the fire prevention knowledge for all hotel staff, to inform visitors about the way route of escape, the improvement of routine maintenance and coaching from managerial and the existence of further research on fire prevention system.
url https://doi.org/10.1051/e3sconf/20186803001
work_keys_str_mv AT tiarlinajimmy analysisoffirecontrolhotelinpalembangcity
AT novrikasari analysisoffirecontrolhotelinpalembangcity
AT sitorusricojanuar analysisoffirecontrolhotelinpalembangcity
_version_ 1724165343631376384