Summary: | The goal of experimental investigations shown in this paper is to estimate the operating efficiency degree of the electrostatic precipitator on a real industrial plant (a the thermal power plant „Gacko“ with the electric power of 310 MW, Bosnia & Herzegovina) and to use the obtained results as a base of periodical engineering or continual measurement and compare them with the investigations of other investigators. The investigation of the electrostatic precipitator performance was done according to BAS ISO 9096:2003. In this paper, the electrostatic precipitator efficiency during the ash particle removal with a wide range of particle sizes from 1 to 250 μm is evaluated. The exploitational experience points out that electrostatic precipitators are efficient for the coals of different quality (coal particles with diameters bigger than 1 μm) and that they could be optimized during the exploitation itself and for some following processes (e.g., flue gas desulphurization). Within the measurement plane, the measurements were made on 20 points per section. It has been noticed that ash removal degrees obtained experimentally (3 investigations) have approximately equal value (95.93 to 97.78%). The best concordance with the results of experimental investigation shows the Deutsch equation, while theoretical models of Zhibin-Guoquan and Nobrega-Falaguasta-Coury do not correspond well to the results of experimental investigations. For the ash particles with the diameters less than 17.5 μm there is no good correlation between investigated theoretical models. The highest deviation of the model for ash particles with diameters less than 17.5 μm is notable in the case of using the Deutsch equation.
|