Adverse reaction regarding titanium-based marker clip: case report of a potential complication

Urszula Wegner, Sarah RainfordDepartment of Breast Imaging, Kettering General Hospital, Kettering, UKCorrespondence: Urszula WegnerManchester University Hospitals, Nightingale Centre, Southmoor Road, Manchester M23 9QZ, UKTel +44 161 291 4444Email Urszula.Wegner@mft.nhs.ukAbstract: Adverse reaction...

Full description

Bibliographic Details
Main Authors: Wegner U, Rainford S
Format: Article
Language:English
Published: Dove Medical Press 2019-08-01
Series:International Medical Case Reports Journal
Subjects:
Online Access:https://www.dovepress.com/adverse-reaction-regarding-titanium-based-marker-clip-case-report-of-a-peer-reviewed-article-IMCRJ
id doaj-5dba5d7dfe7243feb1cf7966c14f369b
record_format Article
spelling doaj-5dba5d7dfe7243feb1cf7966c14f369b2020-11-25T00:58:53ZengDove Medical PressInternational Medical Case Reports Journal1179-142X2019-08-01Volume 1229129548187Adverse reaction regarding titanium-based marker clip: case report of a potential complicationWegner URainford SUrszula Wegner, Sarah RainfordDepartment of Breast Imaging, Kettering General Hospital, Kettering, UKCorrespondence: Urszula WegnerManchester University Hospitals, Nightingale Centre, Southmoor Road, Manchester M23 9QZ, UKTel +44 161 291 4444Email Urszula.Wegner@mft.nhs.ukAbstract: Adverse reaction to titanium-based breast marker clip is a very uncommon complication in medicine. We report a 65-year-old female patient who was referred with left breast lumpiness to the assessment clinic. Breast radiology with interesting sequelae following titanium clip insertion, in combination with literature review, will be discussed. The patient had a history of adverse skin reactions to base metals. However, no allergy specifically to titanium was reported. Imaging findings with regard to the symptomatic breast were nonspecific; thus, multiple core biopsies were taken, and titanium clip was inserted. Subsequent histological examination showed benign changes. However, 7 weeks later, the marked area became very tender and the same patient re-presented to the clinic, requesting removal of the metallic component. Following multidisciplinary meetings and discussions, the person underwent ultrasound-guided vacuum biopsy and the clip was removed. The symptoms completely resolved after the successful procedure, and histological examination revealed lymphocytic infiltration of the tissues. Reactions to titanium-based marker clips are rare and only limited records have been found in the literature. More cases need to be reported in order to establish the full significance of such adverse sequelae. It is recommended that medical history with regard to allergies, prior titanium clip insertions, should be discussed.Keywords: clip marker, breast imaging, sonography, mammography, biopsyhttps://www.dovepress.com/adverse-reaction-regarding-titanium-based-marker-clip-case-report-of-a-peer-reviewed-article-IMCRJClip markerbreast imagingsonographymammographybiopsy
collection DOAJ
language English
format Article
sources DOAJ
author Wegner U
Rainford S
spellingShingle Wegner U
Rainford S
Adverse reaction regarding titanium-based marker clip: case report of a potential complication
International Medical Case Reports Journal
Clip marker
breast imaging
sonography
mammography
biopsy
author_facet Wegner U
Rainford S
author_sort Wegner U
title Adverse reaction regarding titanium-based marker clip: case report of a potential complication
title_short Adverse reaction regarding titanium-based marker clip: case report of a potential complication
title_full Adverse reaction regarding titanium-based marker clip: case report of a potential complication
title_fullStr Adverse reaction regarding titanium-based marker clip: case report of a potential complication
title_full_unstemmed Adverse reaction regarding titanium-based marker clip: case report of a potential complication
title_sort adverse reaction regarding titanium-based marker clip: case report of a potential complication
publisher Dove Medical Press
series International Medical Case Reports Journal
issn 1179-142X
publishDate 2019-08-01
description Urszula Wegner, Sarah RainfordDepartment of Breast Imaging, Kettering General Hospital, Kettering, UKCorrespondence: Urszula WegnerManchester University Hospitals, Nightingale Centre, Southmoor Road, Manchester M23 9QZ, UKTel +44 161 291 4444Email Urszula.Wegner@mft.nhs.ukAbstract: Adverse reaction to titanium-based breast marker clip is a very uncommon complication in medicine. We report a 65-year-old female patient who was referred with left breast lumpiness to the assessment clinic. Breast radiology with interesting sequelae following titanium clip insertion, in combination with literature review, will be discussed. The patient had a history of adverse skin reactions to base metals. However, no allergy specifically to titanium was reported. Imaging findings with regard to the symptomatic breast were nonspecific; thus, multiple core biopsies were taken, and titanium clip was inserted. Subsequent histological examination showed benign changes. However, 7 weeks later, the marked area became very tender and the same patient re-presented to the clinic, requesting removal of the metallic component. Following multidisciplinary meetings and discussions, the person underwent ultrasound-guided vacuum biopsy and the clip was removed. The symptoms completely resolved after the successful procedure, and histological examination revealed lymphocytic infiltration of the tissues. Reactions to titanium-based marker clips are rare and only limited records have been found in the literature. More cases need to be reported in order to establish the full significance of such adverse sequelae. It is recommended that medical history with regard to allergies, prior titanium clip insertions, should be discussed.Keywords: clip marker, breast imaging, sonography, mammography, biopsy
topic Clip marker
breast imaging
sonography
mammography
biopsy
url https://www.dovepress.com/adverse-reaction-regarding-titanium-based-marker-clip-case-report-of-a-peer-reviewed-article-IMCRJ
work_keys_str_mv AT wegneru adversereactionregardingtitaniumbasedmarkerclipcasereportofapotentialcomplication
AT rainfords adversereactionregardingtitaniumbasedmarkerclipcasereportofapotentialcomplication
_version_ 1725220085832876032