Reducing dropout of contact lens wear with Biotrue multipurpose solution

Marjorie J Rah, Mohinder M Merchea, Marianne Q DoktorBausch & Lomb Incorporated, Rochester, NY, USAPurpose: To evaluate whether the use of Biotrue multipurpose solution (MPS) could significantly reduce the likelihood with which patients drop out of using daily wear contact lenses (CLs) amon...

Full description

Bibliographic Details
Main Authors: Rah MJ, Merchea MM, Doktor MQ
Format: Article
Language:English
Published: Dove Medical Press 2014-01-01
Series:Clinical Ophthalmology
Online Access:http://www.dovepress.com/reducing-dropout-of-contact-lens-wear-with-biotrue-multipurpose-soluti-a15622
Description
Summary:Marjorie J Rah, Mohinder M Merchea, Marianne Q DoktorBausch & Lomb Incorporated, Rochester, NY, USAPurpose: To evaluate whether the use of Biotrue multipurpose solution (MPS) could significantly reduce the likelihood with which patients drop out of using daily wear contact lenses (CLs) amongst 18–44-year-old frequent replacement CL wearers.Methods: Daily wear CL subjects habitually using MPSs (other than Biotrue MPS) who reported an intent to imminently drop out of CL wear because of comfort and dryness complaints were recruited to participate in this investigation. Subjects were switched to Biotrue MPS and continued to use habitual CL types with the new MPS for 2 weeks. Subjects completed an online satisfaction questionnaire at baseline and after 2 weeks to assess the change in symptoms and the intent to drop out of CL wear. Six months after completion of the initial study, a follow-up survey was administered to a subset of the initial participants.Results: A total of 153 daily wear (silicone hydrogel and hydrogel) subjects completed this 2-week study with Biotrue MPS. When measuring those with the highest propensity to drop out of lens wear (n=93) after switching to Biotrue MPS, 90% of subjects significantly reduced their likelihood of dropping out of CL wear (P<0.0001). Online interviews were conducted with 73 of the study participants 6 months after completion of the initial study. A total of 93% of participants responded that they were still wearing CLs at least once per week. Of the 7% of respondents who were not currently wearing lenses 6 months after the initial study, two had dropped out of lens wear completely, and three still wore lenses less than once per week.Conclusion: Patients intending to drop out of CL wear due to discomfort and dryness significantly reduced their propensity of discontinuing lens wear following use of Biotrue MPS. Six months after completion of the study, 93% of patients were still wearing CLs at least once per week. Keywords: multipurpose solution, contact lens, dropout
ISSN:1177-5483