The effect of osseodensification and different thread designs on the dental implant primary stability [version 1; peer review: 2 approved, 1 approved with reservations]

Background: It is difficult to achieve good primary stability of dental implants in soft bone, such as that in the posterior maxillae. Osseodensification (OD) burs, working in a non-subtractive fashion, condense the implant osteotomy bone in lateral direction and increase in the bone implant contact...

Full description

Bibliographic Details
Main Authors: Abdullah Saleh Almutairi, Maher Abdullatif Walid, Mohamed Ahmed Alkhodary
Format: Article
Language:English
Published: F1000 Research Ltd 2018-12-01
Series:F1000Research
Online Access:https://f1000research.com/articles/7-1898/v1
id doaj-5cf32e5a12b94d7aad2157ea68ad7dfa
record_format Article
spelling doaj-5cf32e5a12b94d7aad2157ea68ad7dfa2020-11-25T03:50:04ZengF1000 Research LtdF1000Research2046-14022018-12-01710.12688/f1000research.17292.118905The effect of osseodensification and different thread designs on the dental implant primary stability [version 1; peer review: 2 approved, 1 approved with reservations]Abdullah Saleh Almutairi0Maher Abdullatif Walid1Mohamed Ahmed Alkhodary2Department of Periodontology, College of Dentistry, Qassim University, Buraidah, Qassim, 51452, Saudi ArabiaDepartment of Periodontology, College of Dentistry, Qassim University, Buraidah, Qassim, 51452, Saudi ArabiaDepartment of Prosthetic Dental Science, College of Dentistry, Qassim University, Buraidah, Qassim, 51452, Saudi ArabiaBackground: It is difficult to achieve good primary stability of dental implants in soft bone, such as that in the posterior maxillae. Osseodensification (OD) burs, working in a non-subtractive fashion, condense the implant osteotomy bone in lateral direction and increase in the bone implant contact. Also, dental implants with deeper threads, and decreased thread pitch can increase initial bone implant anchorage. Methods: This study utilized 48 custom-made machined surface dental implants that were 13 mm long, with a major diameter of 4.5 mm and a minor diameter of 3.5 mm, a thread pitch of 1 mm, a thread depth of 0.5 mm, and a 4 mm long cutting flute at the apex.  The implants were divided into 4 groups, each group was made of 12 implants with a different thread design; V-shaped, trapezoid, buttress, and reverse buttress. The implants were inserted in 4-mm thick cancellous bone slices obtained from the head of Cow femur bone. The ostoetomies were prepared by conventional drilling and by OD drilling. Each inserted implant was then tested for primary stability using the Periotest. The Periotest values (PTVs) for the implant stability were tabulated and analyzed using a chi square test at significance level p< 0.05. Results: The results of this this study revealed no statistically significant difference between the Periotest readings for the implants in each category placed in either the OD or the regular osteotomies. However, it has been found that the implants placed in regular drilling ostoetomies had a significantly better primary stability than the implants placed in OD osteotomies. Conclusions: It was concluded that OD is not necessary in situations where there is bone of good quality and quantity.https://f1000research.com/articles/7-1898/v1
collection DOAJ
language English
format Article
sources DOAJ
author Abdullah Saleh Almutairi
Maher Abdullatif Walid
Mohamed Ahmed Alkhodary
spellingShingle Abdullah Saleh Almutairi
Maher Abdullatif Walid
Mohamed Ahmed Alkhodary
The effect of osseodensification and different thread designs on the dental implant primary stability [version 1; peer review: 2 approved, 1 approved with reservations]
F1000Research
author_facet Abdullah Saleh Almutairi
Maher Abdullatif Walid
Mohamed Ahmed Alkhodary
author_sort Abdullah Saleh Almutairi
title The effect of osseodensification and different thread designs on the dental implant primary stability [version 1; peer review: 2 approved, 1 approved with reservations]
title_short The effect of osseodensification and different thread designs on the dental implant primary stability [version 1; peer review: 2 approved, 1 approved with reservations]
title_full The effect of osseodensification and different thread designs on the dental implant primary stability [version 1; peer review: 2 approved, 1 approved with reservations]
title_fullStr The effect of osseodensification and different thread designs on the dental implant primary stability [version 1; peer review: 2 approved, 1 approved with reservations]
title_full_unstemmed The effect of osseodensification and different thread designs on the dental implant primary stability [version 1; peer review: 2 approved, 1 approved with reservations]
title_sort effect of osseodensification and different thread designs on the dental implant primary stability [version 1; peer review: 2 approved, 1 approved with reservations]
publisher F1000 Research Ltd
series F1000Research
issn 2046-1402
publishDate 2018-12-01
description Background: It is difficult to achieve good primary stability of dental implants in soft bone, such as that in the posterior maxillae. Osseodensification (OD) burs, working in a non-subtractive fashion, condense the implant osteotomy bone in lateral direction and increase in the bone implant contact. Also, dental implants with deeper threads, and decreased thread pitch can increase initial bone implant anchorage. Methods: This study utilized 48 custom-made machined surface dental implants that were 13 mm long, with a major diameter of 4.5 mm and a minor diameter of 3.5 mm, a thread pitch of 1 mm, a thread depth of 0.5 mm, and a 4 mm long cutting flute at the apex.  The implants were divided into 4 groups, each group was made of 12 implants with a different thread design; V-shaped, trapezoid, buttress, and reverse buttress. The implants were inserted in 4-mm thick cancellous bone slices obtained from the head of Cow femur bone. The ostoetomies were prepared by conventional drilling and by OD drilling. Each inserted implant was then tested for primary stability using the Periotest. The Periotest values (PTVs) for the implant stability were tabulated and analyzed using a chi square test at significance level p< 0.05. Results: The results of this this study revealed no statistically significant difference between the Periotest readings for the implants in each category placed in either the OD or the regular osteotomies. However, it has been found that the implants placed in regular drilling ostoetomies had a significantly better primary stability than the implants placed in OD osteotomies. Conclusions: It was concluded that OD is not necessary in situations where there is bone of good quality and quantity.
url https://f1000research.com/articles/7-1898/v1
work_keys_str_mv AT abdullahsalehalmutairi theeffectofosseodensificationanddifferentthreaddesignsonthedentalimplantprimarystabilityversion1peerreview2approved1approvedwithreservations
AT maherabdullatifwalid theeffectofosseodensificationanddifferentthreaddesignsonthedentalimplantprimarystabilityversion1peerreview2approved1approvedwithreservations
AT mohamedahmedalkhodary theeffectofosseodensificationanddifferentthreaddesignsonthedentalimplantprimarystabilityversion1peerreview2approved1approvedwithreservations
AT abdullahsalehalmutairi effectofosseodensificationanddifferentthreaddesignsonthedentalimplantprimarystabilityversion1peerreview2approved1approvedwithreservations
AT maherabdullatifwalid effectofosseodensificationanddifferentthreaddesignsonthedentalimplantprimarystabilityversion1peerreview2approved1approvedwithreservations
AT mohamedahmedalkhodary effectofosseodensificationanddifferentthreaddesignsonthedentalimplantprimarystabilityversion1peerreview2approved1approvedwithreservations
_version_ 1724492521154805760