Thermal Performance Study on a Sensible Cool Thermal Energy Storage System for Building Air-Conditioning Applications

In most developed and developing nations, nearly 40% of the energy generated is utilized in the building sector, in which nearly 50% of the energy is consumed by building cooling/heating systems. However, the energy requirement for building cooling/heating varies continuously with respect to time. H...

Full description

Bibliographic Details
Main Authors: Kesavan Muthaiyan, Chidambaram Lakshmanan, Kaiwalya Raj, Mangat Ram Sharma, Rajamani Narayanasamy, Pandiyarajan Vellaichamy, Velraj Ramalingam
Format: Article
Language:English
Published: Hindawi Limited 2021-01-01
Series:International Journal of Photoenergy
Online Access:http://dx.doi.org/10.1155/2021/6690128
id doaj-5c676a9caa3e487089ebd826cada7047
record_format Article
spelling doaj-5c676a9caa3e487089ebd826cada70472021-06-21T02:25:53ZengHindawi LimitedInternational Journal of Photoenergy1687-529X2021-01-01202110.1155/2021/6690128Thermal Performance Study on a Sensible Cool Thermal Energy Storage System for Building Air-Conditioning ApplicationsKesavan Muthaiyan0Chidambaram Lakshmanan1Kaiwalya Raj2Mangat Ram Sharma3Rajamani Narayanasamy4Pandiyarajan Vellaichamy5Velraj Ramalingam6Mechanical EngineeringMechanical EngineeringInstitute for Energy StudiesInstitute for Energy StudiesInstitute for Energy StudiesDepartment of Chemical EngineeringInstitute for Energy StudiesIn most developed and developing nations, nearly 40% of the energy generated is utilized in the building sector, in which nearly 50% of the energy is consumed by building cooling/heating systems. However, the energy requirement for building cooling/heating varies continuously with respect to time. Hence, in hot countries, if the cooling system is integrated with a storage system, the cooling system need not be designed for the peak load requirement. Further, this kind of storage system is very useful and economically beneficial in the scenario of dynamic electricity tariff, being introduced in many countries in the emerging renewable energy scenario to solve the grid stability issues. Further, it is very useful to promote microgrid with distributed renewable power generation. Considering the above, the major objective of the present research is to demonstrate the integration of the air-conditioning system with a sensible heat storage unit for residential applications. An experimental setup is constructed, and experiments were conducted to evaluate the heat exchange behavior during the charging and discharging process by varying the inlet temperature and the mass flow rate of the heat exchange fluid through the circuit. It is observed that the set temperature of the cool storage tank is to be maintained above +5°C to achieve better efficiency during the charging process. During the discharging process, the room could be maintained at the required comfort condition for a duration of 285 min with 29 cycles of operations between the set point temperature limits of 25°C to 28°C. When the inlet brine temperature of the cooling unit reached 20°C, in the next cycle, bringing down the room temperature again to 25°C could not be achieved. The results shown in this work are beneficial for efficiently operating the cooling system and useful in promoting renewable energy in the near future in the building sector. Also, the low-temperature sensible heat storage system is capable of maintaining the storage temperature at approximately +4°C, instead of -4°C normally employed in the case of latent heat-based storage system that allows higher performance in the sensible heat storage system.http://dx.doi.org/10.1155/2021/6690128
collection DOAJ
language English
format Article
sources DOAJ
author Kesavan Muthaiyan
Chidambaram Lakshmanan
Kaiwalya Raj
Mangat Ram Sharma
Rajamani Narayanasamy
Pandiyarajan Vellaichamy
Velraj Ramalingam
spellingShingle Kesavan Muthaiyan
Chidambaram Lakshmanan
Kaiwalya Raj
Mangat Ram Sharma
Rajamani Narayanasamy
Pandiyarajan Vellaichamy
Velraj Ramalingam
Thermal Performance Study on a Sensible Cool Thermal Energy Storage System for Building Air-Conditioning Applications
International Journal of Photoenergy
author_facet Kesavan Muthaiyan
Chidambaram Lakshmanan
Kaiwalya Raj
Mangat Ram Sharma
Rajamani Narayanasamy
Pandiyarajan Vellaichamy
Velraj Ramalingam
author_sort Kesavan Muthaiyan
title Thermal Performance Study on a Sensible Cool Thermal Energy Storage System for Building Air-Conditioning Applications
title_short Thermal Performance Study on a Sensible Cool Thermal Energy Storage System for Building Air-Conditioning Applications
title_full Thermal Performance Study on a Sensible Cool Thermal Energy Storage System for Building Air-Conditioning Applications
title_fullStr Thermal Performance Study on a Sensible Cool Thermal Energy Storage System for Building Air-Conditioning Applications
title_full_unstemmed Thermal Performance Study on a Sensible Cool Thermal Energy Storage System for Building Air-Conditioning Applications
title_sort thermal performance study on a sensible cool thermal energy storage system for building air-conditioning applications
publisher Hindawi Limited
series International Journal of Photoenergy
issn 1687-529X
publishDate 2021-01-01
description In most developed and developing nations, nearly 40% of the energy generated is utilized in the building sector, in which nearly 50% of the energy is consumed by building cooling/heating systems. However, the energy requirement for building cooling/heating varies continuously with respect to time. Hence, in hot countries, if the cooling system is integrated with a storage system, the cooling system need not be designed for the peak load requirement. Further, this kind of storage system is very useful and economically beneficial in the scenario of dynamic electricity tariff, being introduced in many countries in the emerging renewable energy scenario to solve the grid stability issues. Further, it is very useful to promote microgrid with distributed renewable power generation. Considering the above, the major objective of the present research is to demonstrate the integration of the air-conditioning system with a sensible heat storage unit for residential applications. An experimental setup is constructed, and experiments were conducted to evaluate the heat exchange behavior during the charging and discharging process by varying the inlet temperature and the mass flow rate of the heat exchange fluid through the circuit. It is observed that the set temperature of the cool storage tank is to be maintained above +5°C to achieve better efficiency during the charging process. During the discharging process, the room could be maintained at the required comfort condition for a duration of 285 min with 29 cycles of operations between the set point temperature limits of 25°C to 28°C. When the inlet brine temperature of the cooling unit reached 20°C, in the next cycle, bringing down the room temperature again to 25°C could not be achieved. The results shown in this work are beneficial for efficiently operating the cooling system and useful in promoting renewable energy in the near future in the building sector. Also, the low-temperature sensible heat storage system is capable of maintaining the storage temperature at approximately +4°C, instead of -4°C normally employed in the case of latent heat-based storage system that allows higher performance in the sensible heat storage system.
url http://dx.doi.org/10.1155/2021/6690128
work_keys_str_mv AT kesavanmuthaiyan thermalperformancestudyonasensiblecoolthermalenergystoragesystemforbuildingairconditioningapplications
AT chidambaramlakshmanan thermalperformancestudyonasensiblecoolthermalenergystoragesystemforbuildingairconditioningapplications
AT kaiwalyaraj thermalperformancestudyonasensiblecoolthermalenergystoragesystemforbuildingairconditioningapplications
AT mangatramsharma thermalperformancestudyonasensiblecoolthermalenergystoragesystemforbuildingairconditioningapplications
AT rajamaninarayanasamy thermalperformancestudyonasensiblecoolthermalenergystoragesystemforbuildingairconditioningapplications
AT pandiyarajanvellaichamy thermalperformancestudyonasensiblecoolthermalenergystoragesystemforbuildingairconditioningapplications
AT velrajramalingam thermalperformancestudyonasensiblecoolthermalenergystoragesystemforbuildingairconditioningapplications
_version_ 1721369107163512832