Phaseless Parametric Inversion for System Calibration and Obtaining Prior Information
Electromagnetic inversion systems require that the experimental data be calibrated to the computational inversion model being used. In addition, accurate prior information provided to the inversion algorithm leads to higher-quality images. For some applications of inversion, such as stored grain ima...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
IEEE
2019-01-01
|
Series: | IEEE Access |
Subjects: | |
Online Access: | https://ieeexplore.ieee.org/document/8825792/ |
id |
doaj-5bf4f079c10d4e94b108a3139df09355 |
---|---|
record_format |
Article |
spelling |
doaj-5bf4f079c10d4e94b108a3139df093552021-03-29T23:38:37ZengIEEEIEEE Access2169-35362019-01-01712873512874510.1109/ACCESS.2019.29397258825792Phaseless Parametric Inversion for System Calibration and Obtaining Prior InformationColin Gilmore0https://orcid.org/0000-0002-6958-3545Ian Jeffrey1https://orcid.org/0000-0003-1312-3248Mohammad Asefi2Nicholas T. Geddert3Kevin G. Brown4Joe Lovetri5Department of Electrical and Computer Engineering, University of Manitoba, Winnipeg, MB, CanadaDepartment of Electrical and Computer Engineering, University of Manitoba, Winnipeg, MB, Canada151 Research, Inc., Winnipeg, MB, Canada151 Research, Inc., Winnipeg, MB, Canada151 Research, Inc., Winnipeg, MB, CanadaDepartment of Electrical and Computer Engineering, University of Manitoba, Winnipeg, MB, CanadaElectromagnetic inversion systems require that the experimental data be calibrated to the computational inversion model being used. In addition, accurate prior information provided to the inversion algorithm leads to higher-quality images. For some applications of inversion, such as stored grain imaging or geophysical inversion, known (calibration) targets cannot be easily introduced into the imaging region and the ability to determine prior information can be limited. In an attempt to solve the problem of calibrating data from such field-inversion systems, we introduce a work flow where: (1) a simple parametric physical model of the scattering background is obtained via a phaseless (magnitude only data) inversion algorithm that works on phase-corrupted, uncalibrated total-field measurements, and (2) we then use this simple physical model to generate calibration and prior information for subsequent full-data (magnitude and phase) inversion. Using an example of in-bin stored grain imaging, the inverted parameters are the grain angle of repose, grain height, and the average bulk permittivity of the grain. Using uncalibrated total-field data, we show that the proposed work flow obtains the overall structure of the grain in a bin despite the use of this raw data. We then show that the simple physical model can be used as both a calibration data set as well as the prior information about the grain target in a full-data (magnitude and phase) inversion. The use of this phaseless algorithm means we are able to remotely calibrate imaging systems, and obtain critical prior information about the imaging region without introducing a calibration target or physically measuring the imaging region in other ways.https://ieeexplore.ieee.org/document/8825792/Inverse problemscalibrationmicrowave tomographyinverse imaging |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Colin Gilmore Ian Jeffrey Mohammad Asefi Nicholas T. Geddert Kevin G. Brown Joe Lovetri |
spellingShingle |
Colin Gilmore Ian Jeffrey Mohammad Asefi Nicholas T. Geddert Kevin G. Brown Joe Lovetri Phaseless Parametric Inversion for System Calibration and Obtaining Prior Information IEEE Access Inverse problems calibration microwave tomography inverse imaging |
author_facet |
Colin Gilmore Ian Jeffrey Mohammad Asefi Nicholas T. Geddert Kevin G. Brown Joe Lovetri |
author_sort |
Colin Gilmore |
title |
Phaseless Parametric Inversion for System Calibration and Obtaining Prior Information |
title_short |
Phaseless Parametric Inversion for System Calibration and Obtaining Prior Information |
title_full |
Phaseless Parametric Inversion for System Calibration and Obtaining Prior Information |
title_fullStr |
Phaseless Parametric Inversion for System Calibration and Obtaining Prior Information |
title_full_unstemmed |
Phaseless Parametric Inversion for System Calibration and Obtaining Prior Information |
title_sort |
phaseless parametric inversion for system calibration and obtaining prior information |
publisher |
IEEE |
series |
IEEE Access |
issn |
2169-3536 |
publishDate |
2019-01-01 |
description |
Electromagnetic inversion systems require that the experimental data be calibrated to the computational inversion model being used. In addition, accurate prior information provided to the inversion algorithm leads to higher-quality images. For some applications of inversion, such as stored grain imaging or geophysical inversion, known (calibration) targets cannot be easily introduced into the imaging region and the ability to determine prior information can be limited. In an attempt to solve the problem of calibrating data from such field-inversion systems, we introduce a work flow where: (1) a simple parametric physical model of the scattering background is obtained via a phaseless (magnitude only data) inversion algorithm that works on phase-corrupted, uncalibrated total-field measurements, and (2) we then use this simple physical model to generate calibration and prior information for subsequent full-data (magnitude and phase) inversion. Using an example of in-bin stored grain imaging, the inverted parameters are the grain angle of repose, grain height, and the average bulk permittivity of the grain. Using uncalibrated total-field data, we show that the proposed work flow obtains the overall structure of the grain in a bin despite the use of this raw data. We then show that the simple physical model can be used as both a calibration data set as well as the prior information about the grain target in a full-data (magnitude and phase) inversion. The use of this phaseless algorithm means we are able to remotely calibrate imaging systems, and obtain critical prior information about the imaging region without introducing a calibration target or physically measuring the imaging region in other ways. |
topic |
Inverse problems calibration microwave tomography inverse imaging |
url |
https://ieeexplore.ieee.org/document/8825792/ |
work_keys_str_mv |
AT colingilmore phaselessparametricinversionforsystemcalibrationandobtainingpriorinformation AT ianjeffrey phaselessparametricinversionforsystemcalibrationandobtainingpriorinformation AT mohammadasefi phaselessparametricinversionforsystemcalibrationandobtainingpriorinformation AT nicholastgeddert phaselessparametricinversionforsystemcalibrationandobtainingpriorinformation AT kevingbrown phaselessparametricinversionforsystemcalibrationandobtainingpriorinformation AT joelovetri phaselessparametricinversionforsystemcalibrationandobtainingpriorinformation |
_version_ |
1724189082752385024 |