Entropy generation for the blood flow in an artery with multiple stenosis having a catheter

This article explicates the blood flow across an artery with multiple stenosis at outer wall and a thrombus at the centre. The symmetric multiple stenosis and non-symmetric multiple stenosis shapes are both considered in this study. Entropy analysis is also taken into account for a detailed study of...

Full description

Bibliographic Details
Main Authors: A.M. Zidan, L.B. McCash, Salman Akhtar, Anber Saleem, Alibek Issakhov, Sohail Nadeem
Format: Article
Language:English
Published: Elsevier 2021-12-01
Series:Alexandria Engineering Journal
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S1110016821003008
id doaj-5bd4d4873fbe41c5908c3c07cc193416
record_format Article
spelling doaj-5bd4d4873fbe41c5908c3c07cc1934162021-06-09T05:49:58ZengElsevierAlexandria Engineering Journal1110-01682021-12-0160657415748Entropy generation for the blood flow in an artery with multiple stenosis having a catheterA.M. Zidan0L.B. McCash1Salman Akhtar2Anber Saleem3Alibek Issakhov4Sohail Nadeem5Department of Mathematics, College of Science King Khalid University, P.O. Box: 9004, Abha 61413, Saudi ArabiaSchool of Mathematics & Actuarial Science, Univerisity of Leicester, Leicester LE1 7RH, UKDepartment of Mathematics, Quaid-i-Azam University 45320, Islamabad 44000, PakistanDepartment of Anatomy, School of Dentistry, Shaheed Zulfiqar Ali Bhutto Medical University Islamabad, PakistanAl-Farabi Kazakh National University, Faculty of Mechanics and Mathematics, av. al-Farabi 71, Almaty, KazakhstanDepartment of Mathematics, Quaid-i-Azam University 45320, Islamabad 44000, Pakistan; Corresponding author.This article explicates the blood flow across an artery with multiple stenosis at outer wall and a thrombus at the centre. The symmetric multiple stenosis and non-symmetric multiple stenosis shapes are both considered in this study. Entropy analysis is also taken into account for a detailed study of irreversibility. The governing equations are interpreted with provided boundary conditions and exact mathematical solutions are developed. Further, these exact solutions are elucidated graphically. Streamlines show that the closed contours are symmetric in shape for symmetric multiple stenosis but non-symmetric in shape for non-symmetric multiple stenosis shape. The increase in multiple stenosis heights, increases the shear stress at wall having multiple stenosis.http://www.sciencedirect.com/science/article/pii/S1110016821003008Multiple stenosed arteryThrombusCatheterEntropy
collection DOAJ
language English
format Article
sources DOAJ
author A.M. Zidan
L.B. McCash
Salman Akhtar
Anber Saleem
Alibek Issakhov
Sohail Nadeem
spellingShingle A.M. Zidan
L.B. McCash
Salman Akhtar
Anber Saleem
Alibek Issakhov
Sohail Nadeem
Entropy generation for the blood flow in an artery with multiple stenosis having a catheter
Alexandria Engineering Journal
Multiple stenosed artery
Thrombus
Catheter
Entropy
author_facet A.M. Zidan
L.B. McCash
Salman Akhtar
Anber Saleem
Alibek Issakhov
Sohail Nadeem
author_sort A.M. Zidan
title Entropy generation for the blood flow in an artery with multiple stenosis having a catheter
title_short Entropy generation for the blood flow in an artery with multiple stenosis having a catheter
title_full Entropy generation for the blood flow in an artery with multiple stenosis having a catheter
title_fullStr Entropy generation for the blood flow in an artery with multiple stenosis having a catheter
title_full_unstemmed Entropy generation for the blood flow in an artery with multiple stenosis having a catheter
title_sort entropy generation for the blood flow in an artery with multiple stenosis having a catheter
publisher Elsevier
series Alexandria Engineering Journal
issn 1110-0168
publishDate 2021-12-01
description This article explicates the blood flow across an artery with multiple stenosis at outer wall and a thrombus at the centre. The symmetric multiple stenosis and non-symmetric multiple stenosis shapes are both considered in this study. Entropy analysis is also taken into account for a detailed study of irreversibility. The governing equations are interpreted with provided boundary conditions and exact mathematical solutions are developed. Further, these exact solutions are elucidated graphically. Streamlines show that the closed contours are symmetric in shape for symmetric multiple stenosis but non-symmetric in shape for non-symmetric multiple stenosis shape. The increase in multiple stenosis heights, increases the shear stress at wall having multiple stenosis.
topic Multiple stenosed artery
Thrombus
Catheter
Entropy
url http://www.sciencedirect.com/science/article/pii/S1110016821003008
work_keys_str_mv AT amzidan entropygenerationforthebloodflowinanarterywithmultiplestenosishavingacatheter
AT lbmccash entropygenerationforthebloodflowinanarterywithmultiplestenosishavingacatheter
AT salmanakhtar entropygenerationforthebloodflowinanarterywithmultiplestenosishavingacatheter
AT anbersaleem entropygenerationforthebloodflowinanarterywithmultiplestenosishavingacatheter
AT alibekissakhov entropygenerationforthebloodflowinanarterywithmultiplestenosishavingacatheter
AT sohailnadeem entropygenerationforthebloodflowinanarterywithmultiplestenosishavingacatheter
_version_ 1721389159339261952