Radiation Doses to Paediatric Patients Undergoing Voiding Cystourethrography (VCUG)

Objective: The aims were to quantify and evaluate the radiation doses and to estimate the radiation risk for the paediatric patients undergoing VCUG according to the protocol used in Siriraj Hospital. Methods: Among 93 children of the age of 0-15 years who underwent VCUG at Siriraj Hospital, we repo...

Full description

Bibliographic Details
Main Author: Napapong Pongnapang
Format: Article
Language:English
Published: Mahidol University 2016-04-01
Series:Siriraj Medical Journal
Online Access:https://he02.tci-thaijo.org/index.php/sirirajmedj/article/view/55190
id doaj-5bcf55c12ceb4ba3af086c02bfa07fa7
record_format Article
spelling doaj-5bcf55c12ceb4ba3af086c02bfa07fa72021-08-13T09:52:54ZengMahidol UniversitySiriraj Medical Journal2228-80822016-04-01682Radiation Doses to Paediatric Patients Undergoing Voiding Cystourethrography (VCUG)Napapong Pongnapang0Department of Radiological Technology, Faculty of Medical Technology, Mahidol University, Bangkok 10700Objective: The aims were to quantify and evaluate the radiation doses and to estimate the radiation risk for the paediatric patients undergoing VCUG according to the protocol used in Siriraj Hospital. Methods: Among 93 children of the age of 0-15 years who underwent VCUG at Siriraj Hospital, we reported the patient’s data, the radiation doses determined by a DAP meter and the baseline data including the entrance skin dose (ESD), dose area product (DAP) and the effective dose according to the patient’s age. Results: The mean ESD, DAP and effective doses of 93 paediatric patients were 3.63 mGy, 92.9 cGycm2 and 0.20 mSv, respectively. The initial local DRLs of DAP for VCUG examination at Siriraj Hospital were 37, 77 and 105 cGy.cm2 in the age range of 0-1, >1-5,  and >5-10 years, respectively. The ESD, DAP and effective doses were in ranges of 0.36-81.96 mGy, 1.37-1506.90 cGy.cm2 and 0.003-3.16 mSv, respectively. Conclusion: The initial local DRLs of DAP for VCUG examinations at Siriraj Hospital were less than in NRPB and Siriwiladluk T, et al in the age range of 0-1, >1-5,  and >5-10 years. Due to the small number of patients at the age of >10-15 years (n=4), it was inconclusive of the dose level in this age group. The lifetime risk of radiation induced cancer was approximately calculated to be 2.6 per 100,000. Keywords: Voiding cystourethrography (VCUG), radiation dose, dose area product (DAP), dose reference levels (DRLs), paediatric patient https://he02.tci-thaijo.org/index.php/sirirajmedj/article/view/55190
collection DOAJ
language English
format Article
sources DOAJ
author Napapong Pongnapang
spellingShingle Napapong Pongnapang
Radiation Doses to Paediatric Patients Undergoing Voiding Cystourethrography (VCUG)
Siriraj Medical Journal
author_facet Napapong Pongnapang
author_sort Napapong Pongnapang
title Radiation Doses to Paediatric Patients Undergoing Voiding Cystourethrography (VCUG)
title_short Radiation Doses to Paediatric Patients Undergoing Voiding Cystourethrography (VCUG)
title_full Radiation Doses to Paediatric Patients Undergoing Voiding Cystourethrography (VCUG)
title_fullStr Radiation Doses to Paediatric Patients Undergoing Voiding Cystourethrography (VCUG)
title_full_unstemmed Radiation Doses to Paediatric Patients Undergoing Voiding Cystourethrography (VCUG)
title_sort radiation doses to paediatric patients undergoing voiding cystourethrography (vcug)
publisher Mahidol University
series Siriraj Medical Journal
issn 2228-8082
publishDate 2016-04-01
description Objective: The aims were to quantify and evaluate the radiation doses and to estimate the radiation risk for the paediatric patients undergoing VCUG according to the protocol used in Siriraj Hospital. Methods: Among 93 children of the age of 0-15 years who underwent VCUG at Siriraj Hospital, we reported the patient’s data, the radiation doses determined by a DAP meter and the baseline data including the entrance skin dose (ESD), dose area product (DAP) and the effective dose according to the patient’s age. Results: The mean ESD, DAP and effective doses of 93 paediatric patients were 3.63 mGy, 92.9 cGycm2 and 0.20 mSv, respectively. The initial local DRLs of DAP for VCUG examination at Siriraj Hospital were 37, 77 and 105 cGy.cm2 in the age range of 0-1, >1-5,  and >5-10 years, respectively. The ESD, DAP and effective doses were in ranges of 0.36-81.96 mGy, 1.37-1506.90 cGy.cm2 and 0.003-3.16 mSv, respectively. Conclusion: The initial local DRLs of DAP for VCUG examinations at Siriraj Hospital were less than in NRPB and Siriwiladluk T, et al in the age range of 0-1, >1-5,  and >5-10 years. Due to the small number of patients at the age of >10-15 years (n=4), it was inconclusive of the dose level in this age group. The lifetime risk of radiation induced cancer was approximately calculated to be 2.6 per 100,000. Keywords: Voiding cystourethrography (VCUG), radiation dose, dose area product (DAP), dose reference levels (DRLs), paediatric patient
url https://he02.tci-thaijo.org/index.php/sirirajmedj/article/view/55190
work_keys_str_mv AT napapongpongnapang radiationdosestopaediatricpatientsundergoingvoidingcystourethrographyvcug
_version_ 1721208744439709696