Multifunctional backup electricity supply for NPP auxiliary needs based on combined-cycle power plant with hydrogen overheating

Approach is suggested of combining nuclear power plant with combined cycle gas turbine unit and hydrogen producing complex which, while operated in normal conditions, give the possibility to increase plant capacity and, in case of complete blackout, to ensure supply of electricity for covering auxil...

Full description

Bibliographic Details
Main Author: V.E. Yurin
Format: Article
Language:English
Published: National Research Nuclear University (MEPhI) 2016-12-01
Series:Nuclear Energy and Technology
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2452303816301030
id doaj-5b4286c52de247339622055c77d77552
record_format Article
spelling doaj-5b4286c52de247339622055c77d775522020-11-25T01:12:43ZengNational Research Nuclear University (MEPhI)Nuclear Energy and Technology2452-30382016-12-012423123510.1016/j.nucet.2016.11.001Multifunctional backup electricity supply for NPP auxiliary needs based on combined-cycle power plant with hydrogen overheatingV.E. YurinApproach is suggested of combining nuclear power plant with combined cycle gas turbine unit and hydrogen producing complex which, while operated in normal conditions, give the possibility to increase plant capacity and, in case of complete blackout, to ensure supply of electricity for covering auxiliary needs of the NPP. It is suggested to use hydrogen for overheating generated steam by exhaust gases of the gas turbine plant included in the composition of the combined cycle gas turbine unit. Combined cycle gas turbine unit must be installed beyond the NPP site. Hydrogen is to be generated by electrolysis of water using cheap off-peak energy produced by the NPP during nighttime, following which hydrogen will be efficiently used during the day for enhancing parameters of steam before the gas turbine included in the composition of the combined cycle gas turbine unit. Probabilistic assessment was performed of reliability of the proposed system in the conditions of loss of power supply for the case of joint use of the combined cycle gas turbine unit and emergency electric power supply channels equipped with diesel generators. The proposed system allows ensuring supply of electricity for covering auxiliary needs of the NPP during more than 72h. Use of the steam turbine plant included in the composition of the combined cycle gas turbine unit is possible for covering auxiliary needs of the NPP in case of failure of gas turbine plants. Steam turbine can be operated due to the generation of additional steam during incineration of hydrogen in oxygen. With appropriate modernization the system allows using decay heat released in the nuclear reactor core. It was established that the proposed option of combining NPP with combined cycle gas turbine unit in combination with hydrogen generating complex allows enhancing reliability of supply of electricity for covering auxiliary needs of the NPP in emergency conditions accompanied with loss of electric power supply.http://www.sciencedirect.com/science/article/pii/S2452303816301030Emergency electricity supplyHydrogen cycleCombustion chamberNuclear power plantCombined cycle gas turbine unitManeuverabilitySafetyBack-up electricity supply for covering auxiliary needs of the NPPNuclear emergency with complete loss of electric power supply
collection DOAJ
language English
format Article
sources DOAJ
author V.E. Yurin
spellingShingle V.E. Yurin
Multifunctional backup electricity supply for NPP auxiliary needs based on combined-cycle power plant with hydrogen overheating
Nuclear Energy and Technology
Emergency electricity supply
Hydrogen cycle
Combustion chamber
Nuclear power plant
Combined cycle gas turbine unit
Maneuverability
Safety
Back-up electricity supply for covering auxiliary needs of the NPP
Nuclear emergency with complete loss of electric power supply
author_facet V.E. Yurin
author_sort V.E. Yurin
title Multifunctional backup electricity supply for NPP auxiliary needs based on combined-cycle power plant with hydrogen overheating
title_short Multifunctional backup electricity supply for NPP auxiliary needs based on combined-cycle power plant with hydrogen overheating
title_full Multifunctional backup electricity supply for NPP auxiliary needs based on combined-cycle power plant with hydrogen overheating
title_fullStr Multifunctional backup electricity supply for NPP auxiliary needs based on combined-cycle power plant with hydrogen overheating
title_full_unstemmed Multifunctional backup electricity supply for NPP auxiliary needs based on combined-cycle power plant with hydrogen overheating
title_sort multifunctional backup electricity supply for npp auxiliary needs based on combined-cycle power plant with hydrogen overheating
publisher National Research Nuclear University (MEPhI)
series Nuclear Energy and Technology
issn 2452-3038
publishDate 2016-12-01
description Approach is suggested of combining nuclear power plant with combined cycle gas turbine unit and hydrogen producing complex which, while operated in normal conditions, give the possibility to increase plant capacity and, in case of complete blackout, to ensure supply of electricity for covering auxiliary needs of the NPP. It is suggested to use hydrogen for overheating generated steam by exhaust gases of the gas turbine plant included in the composition of the combined cycle gas turbine unit. Combined cycle gas turbine unit must be installed beyond the NPP site. Hydrogen is to be generated by electrolysis of water using cheap off-peak energy produced by the NPP during nighttime, following which hydrogen will be efficiently used during the day for enhancing parameters of steam before the gas turbine included in the composition of the combined cycle gas turbine unit. Probabilistic assessment was performed of reliability of the proposed system in the conditions of loss of power supply for the case of joint use of the combined cycle gas turbine unit and emergency electric power supply channels equipped with diesel generators. The proposed system allows ensuring supply of electricity for covering auxiliary needs of the NPP during more than 72h. Use of the steam turbine plant included in the composition of the combined cycle gas turbine unit is possible for covering auxiliary needs of the NPP in case of failure of gas turbine plants. Steam turbine can be operated due to the generation of additional steam during incineration of hydrogen in oxygen. With appropriate modernization the system allows using decay heat released in the nuclear reactor core. It was established that the proposed option of combining NPP with combined cycle gas turbine unit in combination with hydrogen generating complex allows enhancing reliability of supply of electricity for covering auxiliary needs of the NPP in emergency conditions accompanied with loss of electric power supply.
topic Emergency electricity supply
Hydrogen cycle
Combustion chamber
Nuclear power plant
Combined cycle gas turbine unit
Maneuverability
Safety
Back-up electricity supply for covering auxiliary needs of the NPP
Nuclear emergency with complete loss of electric power supply
url http://www.sciencedirect.com/science/article/pii/S2452303816301030
work_keys_str_mv AT veyurin multifunctionalbackupelectricitysupplyfornppauxiliaryneedsbasedoncombinedcyclepowerplantwithhydrogenoverheating
_version_ 1725165422964113408