How Do We Monitor Oxygenation during the Management of PPHN? Alveolar, Arterial, Mixed Venous Oxygen Tension or Peripheral Saturation?

Oxygen is a pulmonary vasodilator and plays an important role in mediating circulatory transition from fetal to postnatal period. Oxygen tension (PO<sub>2</sub>) in the alveolus (PAO<sub>2</sub>) and pulmonary artery (PaO<sub>2</sub>) are the main factors that inf...

Full description

Bibliographic Details
Main Authors: Praveen Chandrasekharan, Munmun Rawat, Satyan Lakshminrusimha
Format: Article
Language:English
Published: MDPI AG 2020-10-01
Series:Children
Subjects:
Online Access:https://www.mdpi.com/2227-9067/7/10/180
id doaj-5ad8abe4fb804359ad4d0e78ea5a4595
record_format Article
spelling doaj-5ad8abe4fb804359ad4d0e78ea5a45952021-04-02T11:08:46ZengMDPI AGChildren2227-90672020-10-01718018010.3390/children7100180How Do We Monitor Oxygenation during the Management of PPHN? Alveolar, Arterial, Mixed Venous Oxygen Tension or Peripheral Saturation?Praveen Chandrasekharan0Munmun Rawat1Satyan Lakshminrusimha2Division of Neonatology, Department of Pediatrics, University at Buffalo, Buffalo, NY 14260, USADivision of Neonatology, Department of Pediatrics, University at Buffalo, Buffalo, NY 14260, USADivision of Neonatology, Department of Pediatrics, University of California Davis, Davis, CA 95616, USAOxygen is a pulmonary vasodilator and plays an important role in mediating circulatory transition from fetal to postnatal period. Oxygen tension (PO<sub>2</sub>) in the alveolus (PAO<sub>2</sub>) and pulmonary artery (PaO<sub>2</sub>) are the main factors that influence hypoxic pulmonary vasoconstriction (HPV). Inability to achieve adequate pulmonary vasodilation at birth leads to persistent pulmonary hypertension of the newborn (PPHN). Supplemental oxygen therapy is the mainstay of PPHN management. However, optimal monitoring and targeting of oxygenation to achieve low pulmonary vascular resistance (PVR) and optimizing oxygen delivery to vital organs remains unknown. Noninvasive pulse oximetry measures peripheral saturations (SpO<sub>2</sub>) and a target range of 91–95% are recommended during acute PPHN management. However, for a given SpO<sub>2</sub>, there is wide variability in arterial PaO<sub>2</sub>, especially with variations in hemoglobin type (HbF or HbA due to transfusions), pH and body temperature. This review evaluates the role of alveolar, preductal, postductal, mixed venous PO<sub>2</sub>, and SpO<sub>2</sub> in the management of PPHN. Translational and clinical studies suggest maintaining a PaO<sub>2</sub> of 50–80 mmHg decreases PVR and augments pulmonary vasodilator management. Nevertheless, there are no randomized clinical trials evaluating outcomes in PPHN targeting SpO<sub>2</sub> or PO<sub>2</sub>. Also, most critically ill patients have umbilical arterial catheters and postductal PaO<sub>2</sub> may not be an accurate assessment of oxygen delivery to vital organs or factors influencing HPV. The mixed venous oxygen tension from umbilical venous catheter blood gas may assess pulmonary arterial PO<sub>2</sub> and potentially predict HPV. It is crucial to conduct randomized controlled studies with different PO<sub>2</sub>/SpO<sub>2</sub> target ranges for the management of PPHN and compare outcomes.https://www.mdpi.com/2227-9067/7/10/180oxygenationPPHNoxygen tension
collection DOAJ
language English
format Article
sources DOAJ
author Praveen Chandrasekharan
Munmun Rawat
Satyan Lakshminrusimha
spellingShingle Praveen Chandrasekharan
Munmun Rawat
Satyan Lakshminrusimha
How Do We Monitor Oxygenation during the Management of PPHN? Alveolar, Arterial, Mixed Venous Oxygen Tension or Peripheral Saturation?
Children
oxygenation
PPHN
oxygen tension
author_facet Praveen Chandrasekharan
Munmun Rawat
Satyan Lakshminrusimha
author_sort Praveen Chandrasekharan
title How Do We Monitor Oxygenation during the Management of PPHN? Alveolar, Arterial, Mixed Venous Oxygen Tension or Peripheral Saturation?
title_short How Do We Monitor Oxygenation during the Management of PPHN? Alveolar, Arterial, Mixed Venous Oxygen Tension or Peripheral Saturation?
title_full How Do We Monitor Oxygenation during the Management of PPHN? Alveolar, Arterial, Mixed Venous Oxygen Tension or Peripheral Saturation?
title_fullStr How Do We Monitor Oxygenation during the Management of PPHN? Alveolar, Arterial, Mixed Venous Oxygen Tension or Peripheral Saturation?
title_full_unstemmed How Do We Monitor Oxygenation during the Management of PPHN? Alveolar, Arterial, Mixed Venous Oxygen Tension or Peripheral Saturation?
title_sort how do we monitor oxygenation during the management of pphn? alveolar, arterial, mixed venous oxygen tension or peripheral saturation?
publisher MDPI AG
series Children
issn 2227-9067
publishDate 2020-10-01
description Oxygen is a pulmonary vasodilator and plays an important role in mediating circulatory transition from fetal to postnatal period. Oxygen tension (PO<sub>2</sub>) in the alveolus (PAO<sub>2</sub>) and pulmonary artery (PaO<sub>2</sub>) are the main factors that influence hypoxic pulmonary vasoconstriction (HPV). Inability to achieve adequate pulmonary vasodilation at birth leads to persistent pulmonary hypertension of the newborn (PPHN). Supplemental oxygen therapy is the mainstay of PPHN management. However, optimal monitoring and targeting of oxygenation to achieve low pulmonary vascular resistance (PVR) and optimizing oxygen delivery to vital organs remains unknown. Noninvasive pulse oximetry measures peripheral saturations (SpO<sub>2</sub>) and a target range of 91–95% are recommended during acute PPHN management. However, for a given SpO<sub>2</sub>, there is wide variability in arterial PaO<sub>2</sub>, especially with variations in hemoglobin type (HbF or HbA due to transfusions), pH and body temperature. This review evaluates the role of alveolar, preductal, postductal, mixed venous PO<sub>2</sub>, and SpO<sub>2</sub> in the management of PPHN. Translational and clinical studies suggest maintaining a PaO<sub>2</sub> of 50–80 mmHg decreases PVR and augments pulmonary vasodilator management. Nevertheless, there are no randomized clinical trials evaluating outcomes in PPHN targeting SpO<sub>2</sub> or PO<sub>2</sub>. Also, most critically ill patients have umbilical arterial catheters and postductal PaO<sub>2</sub> may not be an accurate assessment of oxygen delivery to vital organs or factors influencing HPV. The mixed venous oxygen tension from umbilical venous catheter blood gas may assess pulmonary arterial PO<sub>2</sub> and potentially predict HPV. It is crucial to conduct randomized controlled studies with different PO<sub>2</sub>/SpO<sub>2</sub> target ranges for the management of PPHN and compare outcomes.
topic oxygenation
PPHN
oxygen tension
url https://www.mdpi.com/2227-9067/7/10/180
work_keys_str_mv AT praveenchandrasekharan howdowemonitoroxygenationduringthemanagementofpphnalveolararterialmixedvenousoxygentensionorperipheralsaturation
AT munmunrawat howdowemonitoroxygenationduringthemanagementofpphnalveolararterialmixedvenousoxygentensionorperipheralsaturation
AT satyanlakshminrusimha howdowemonitoroxygenationduringthemanagementofpphnalveolararterialmixedvenousoxygentensionorperipheralsaturation
_version_ 1724165551992864768