INFLUENCE OF MIXTURE DESIGN, AGE, AND COOLING REGIME ON POSTFIRE MECHANICAL PROPERTIES OF LIGHTWEIGHT SELF-COMPACTED CONCRETE
The post-fire mechanical properties of concrete represent an important set of parameters in the analysis of structural behavior after the occurrence of a fire. In this study, four mixtures of lightweight selfcompacted concrete with different fillers were tested. The tests were conducted by consideri...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Faculty of Civil Engineering Osijek
2020-01-01
|
Series: | e-GFOS |
Online Access: | http://e-gfos.gfos.hr/egfos/egfospdf/23532 |
id |
doaj-5ad551dac46047649d6cc6f597c8fa8d |
---|---|
record_format |
Article |
spelling |
doaj-5ad551dac46047649d6cc6f597c8fa8d2020-11-25T03:12:08ZengFaculty of Civil Engineering Osijeke-GFOS 1847-89482020-01-01112011210.13167/2020.20.1242083INFLUENCE OF MIXTURE DESIGN, AGE, AND COOLING REGIME ON POSTFIRE MECHANICAL PROPERTIES OF LIGHTWEIGHT SELF-COMPACTED CONCRETEAna RomićSandra Juradin0University of Split, Faculty of Civil Engineering, Architecture and GeodesyThe post-fire mechanical properties of concrete represent an important set of parameters in the analysis of structural behavior after the occurrence of a fire. In this study, four mixtures of lightweight selfcompacted concrete with different fillers were tested. The tests were conducted by considering the ages of the specimens, which, in this study, were two, three, and five years old. The results show the residual mechanical properties of the specimens after they were heated to target temperatures of 300, 500, and 700 °C. After exposure to high temperature, the specimens were either left to gradually cool until they reached room temperature or rapidly cooled by water. A comparative analysis was conducted on the compressive strength, mass, and dynamic modulus of elasticity of the specimens using the codified residual values given in EN 1994 1-2.http://e-gfos.gfos.hr/egfos/egfospdf/23532 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Ana Romić Sandra Juradin |
spellingShingle |
Ana Romić Sandra Juradin INFLUENCE OF MIXTURE DESIGN, AGE, AND COOLING REGIME ON POSTFIRE MECHANICAL PROPERTIES OF LIGHTWEIGHT SELF-COMPACTED CONCRETE e-GFOS |
author_facet |
Ana Romić Sandra Juradin |
author_sort |
Ana Romić |
title |
INFLUENCE OF MIXTURE DESIGN, AGE, AND COOLING REGIME ON POSTFIRE MECHANICAL PROPERTIES OF LIGHTWEIGHT SELF-COMPACTED CONCRETE |
title_short |
INFLUENCE OF MIXTURE DESIGN, AGE, AND COOLING REGIME ON POSTFIRE MECHANICAL PROPERTIES OF LIGHTWEIGHT SELF-COMPACTED CONCRETE |
title_full |
INFLUENCE OF MIXTURE DESIGN, AGE, AND COOLING REGIME ON POSTFIRE MECHANICAL PROPERTIES OF LIGHTWEIGHT SELF-COMPACTED CONCRETE |
title_fullStr |
INFLUENCE OF MIXTURE DESIGN, AGE, AND COOLING REGIME ON POSTFIRE MECHANICAL PROPERTIES OF LIGHTWEIGHT SELF-COMPACTED CONCRETE |
title_full_unstemmed |
INFLUENCE OF MIXTURE DESIGN, AGE, AND COOLING REGIME ON POSTFIRE MECHANICAL PROPERTIES OF LIGHTWEIGHT SELF-COMPACTED CONCRETE |
title_sort |
influence of mixture design, age, and cooling regime on postfire mechanical properties of lightweight self-compacted concrete |
publisher |
Faculty of Civil Engineering Osijek |
series |
e-GFOS |
issn |
1847-8948 |
publishDate |
2020-01-01 |
description |
The post-fire mechanical properties of concrete represent an important set of parameters in the analysis of structural behavior after the occurrence of a fire. In this study, four mixtures of lightweight selfcompacted concrete with different fillers were tested. The tests were conducted by considering the ages of the specimens, which, in this study, were two, three, and five years old. The results show the residual mechanical properties of the specimens after they were heated to target temperatures of 300, 500, and 700 °C. After exposure to high temperature, the specimens were either left to gradually cool until they reached room temperature or rapidly cooled by water. A comparative analysis was conducted on the compressive strength, mass, and dynamic modulus of elasticity of the specimens using the codified residual values given in EN 1994 1-2. |
url |
http://e-gfos.gfos.hr/egfos/egfospdf/23532 |
work_keys_str_mv |
AT anaromic influenceofmixturedesignageandcoolingregimeonpostfiremechanicalpropertiesoflightweightselfcompactedconcrete AT sandrajuradin influenceofmixturedesignageandcoolingregimeonpostfiremechanicalpropertiesoflightweightselfcompactedconcrete |
_version_ |
1724651356555313152 |